ABB 1SBL397001R1300AF80-30-00-13 100-250V50/60HZ-DC Contactor

1 / 2
1SBL397001R1300 ABB, Contactors
Reference Image - Not actual item!
1SBL397001R1300 ABB, Contactors
1SBL397001R1300 ABB, Contactors
1SBL397001R1300 ABB, Contactors

Offer Description

The AF80-30-00-13 is a 3 pole - 1000 V IEC or 600 UL contactor with screw terminals, controlling motors up to 37 kW / 400 V AC (AC-3) or 60 hp / 480 V UL and switching power circuits up to 125 A (AC-1) or 105 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.AF80-30-00-13 100-250V50/60HZ-DC Contactor ABB 1SBL397001R1300

Product Description

The AF80-30-00-13 is a 3 pole - 1000 V IEC or 600 UL contactor with screw terminals, controlling motors up to 37 kW / 400 V AC (AC-3) or 60 hp / 480 V UL and switching power circuits up to 125 A (AC-1) or 105 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Product Details

Brand
ABB
Country of Origin
FR
Part Number
1SBL397001R1300
Tariff Code
85364900
EAN
3471523132931
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7
$433.09
excl. tax
Free Shipping!

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 16-07-2025
Warranty:
12 months
Estimated Delivery:
24-29 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Dimensions

Product Net Width
70 mm
Product Net Depth / Length
116 mm
Product Net Height
125.5 mm
Product Net Weight
1.17 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A(690 V) 60 °C 100 A(690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A(440 V) 60 °C 80 A(500 V) 60 °C 65 A(690 V) 60 °C 49 A(1000 V) 60 °C 25 A(380 / 400 V) 60 °C 80 A(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 80 A(440 V) 60 °C 80 A(500 V) 60 °C 65 A(690 V) 60 °C 49 A(380 / 400 V) 60 °C 80 A(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(400 V) 37 kW(415 V) 45 kW(440 V) 45 kW(500 V) 45 kW(690 V) 45 kW(1000 V) 35 kW(380 / 400 V) 37 kW(220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW(440 V) 45 kW(500 V) 45 kW(690 V) 45 kW(380 / 400 V) 37 kW(220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 125 A(110 V) 2 Poles in Series, 60 °C 100 A(110 V) 2 Poles in Series, 70 °C 85 A(110 V) 3 Poles in Series, 40 °C 125 A(110 V) 3 Poles in Series, 60 °C 100 A(110 V) 3 Poles in Series, 70 °C 85 A(220 V) 3 Poles in Series, 40 °C 125 A(220 V) 3 Poles in Series, 60 °C 100 A(220 V) 3 Poles in Series, 70 °C 85 A(72 V) 1-Pole, 40 °C 125 A(72 V) 1-Pole, 60 °C 100 A(72 V) 1-Pole, 70 °C 85 A(72 V) 2 Poles in Series, 40 °C 125 A(72 V) 2 Poles in Series, 60 °C 100 A(72 V) 2 Poles in Series, 70 °C 85 A(72 V) 3 Poles in Series, 40 °C 125 A(72 V) 3 Poles in Series, 60 °C 100 A(72 V) 3 Poles in Series, 70 °C 85 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 125 A(110 V) 2 Poles in Series, 60 °C 100 A(110 V) 2 Poles in Series, 70 °C 85 A(110 V) 3 Poles in Series, 40 °C 125 A(110 V) 3 Poles in Series, 60 °C 100 A(110 V) 3 Poles in Series, 70 °C 85 A(220 V) 3 Poles in Series, 40 °C 125 A(220 V) 3 Poles in Series, 60 °C 100 A(220 V) 3 Poles in Series, 70 °C 85 A(72 V) 1-Pole, 40 °C 125 A(72 V) 1-Pole, 60 °C 100 A(72 V) 1-Pole, 70 °C 85 A(72 V) 2 Poles in Series, 40 °C 125 A(72 V) 2 Poles in Series, 60 °C 100 A(72 V) 2 Poles in Series, 70 °C 85 A(72 V) 3 Poles in Series, 40 °C 125 A(72 V) 3 Poles in Series, 60 °C 100 A(72 V) 3 Poles in Series, 70 °C 85 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 125 A(110 V) 2 Poles in Series, 60 °C 100 A(110 V) 2 Poles in Series, 70 °C 85 A(110 V) 3 Poles in Series, 40 °C 125 A(110 V) 3 Poles in Series, 60 °C 100 A(110 V) 3 Poles in Series, 70 °C 85 A(220 V) 3 Poles in Series, 40 °C 125 A(220 V) 3 Poles in Series, 60 °C 100 A(220 V) 3 Poles in Series, 70 °C 85 A(72 V) 1-Pole, 40 °C 125 A(72 V) 1-Pole, 60 °C 100 A(72 V) 1-Pole, 70 °C 85 A(72 V) 2 Poles in Series, 40 °C 125 A(72 V) 2 Poles in Series, 60 °C 100 A(72 V) 2 Poles in Series, 70 °C 85 A(72 V) 3 Poles in Series, 40 °C 125 A(72 V) 3 Poles in Series, 60 °C 100 A(72 V) 3 Poles in Series, 70 °C 85 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Coil Consumption
Average Holding Value 50 / 60 Hz 4 V·AAverage Holding Value 50 Hz 4 V·AAverage Holding Value 60 Hz 4 V·AAverage Holding Value DC 2 WAverage Holding Value, from Warm State 2 W
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 msBetween Coil De-energization and NO Contact Opening 17 ... 100 msBetween Coil Energization and NC Contact Opening 38 ... 95 msBetween Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm²Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²Rigid Stranded 1x 6 ... 70 mm²Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mmMain Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal Type
Screw Terminals

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707122
E-Number (Sweden)
3210053

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6
5 ... 300 Hz 3 g closed position / 3 g open position
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: A 25 gClosed, Shock Direction: B1 25 gClosed, Shock Direction: B2 15 gClosed, Shock Direction: C1 25 gClosed, Shock Direction: C2 25 gOpen, Shock Direction: B1 5 g
RoHS Status
Following EU Directive 2011/65/EU

Technical UL/CSA

NEMA Size
3
Continuous Current Rating NEMA
90 A
Horsepower Rating NEMA
(200 V AC) Three Phase 25 Hp(230 V AC) Three Phase 30 Hp(460 V AC) Three Phase 50 Hp(575 V AC) Three Phase 50 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp(200 ... 208 V AC) Three Phase 25 hp(220 ... 240 V AC) Three Phase 30 hp(240 V AC) Single Phase 15 hp(440 ... 480 V AC) Three Phase 60 hp(550 ... 600 V AC) Three Phase 75 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lbMain Circuit 53 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900

Related products

1SVR550107R5100 ABB, Relays
1SVR550107R5100
ABB
CT-ERE Time relay, ON-delay 1c/o, 0.3-30min, 24VAC/DC 220-240VAC
2CDL200110R0001 ABB, Other
2CDL200110R0001
ABB
PS-END-SP - Busbar
2CDS284001R0258 ABB, Power Supply
2CDS284001R0258
ABB
S204P-Z1.6 Miniature Circuit Breaker - 4P - Z - 1.6 A
1SNA238061R0600 ABB, Other
1SNA238061R0600
ABB
RC1010 Terminal Block Markers pre-printed 81->88 (x10) Vertical
1SNK168132R0000 ABB, Other
1SNK168132R0000
ABB
MC812PA Terminal Block Markers pre-printed : V1 (x100) Vertical
EV1030 ABB, Control Cabinets
EV1030
ABB
IS2-EV1030 Control and Automation Board
1SNK705011R0000 ABB, Other
1SNK705011R0000
ABB
ZK2.5-3P PI-Spring clamp Terminal Block - Feed-through - Grey
1SDA067435R1 ABB, Other
1SDA067435R1
ABB
XT1S 160 TMD 125-1250 3p F F
05169 ABB, Cables
05169
ABB
WIRING DUCT PVC 80X60 4/6 LUCA
1SDA038092R1 ABB, Other
1SDA038092R1
ABB
Racking-out lever
1SDA055025R1 ABB, Other
1SDA055025R1
ABB
KIT FC CuAl 1x300mm2 T5 400 4pcs