1 / 1
thumbnail

Descripción

Activo maduro
LP1K0910ED is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 48 V DC coil and 1NO auxiliary contact allowing easy integration to all control systems. LP1K0910ED is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 4kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it can be easily integrated into all control systems thanks to its 48V DC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Ready for connection to all control systems thanks to a 48V DC control voltage and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
Country of Origin
FR
Part Number
LP1K0910ED
Tariff Code
85364190
EAN
3389110496352
UNSPSC
39121529
€43.42
net
1
Métodos de pago:
Mejor oferta de:
NLProveedor de confianza de Automa.Net
Disponibilidad:
3 piezas
En stock
Actualizado en: 09-11-2024
Entrega Estimada:
Bajo pedido
Condición:
Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
Un total de 86 Parts In-Stock de 18 Distributors
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Ofertas Disponibles (18)

LP1K0910ED product image
Schneider Electric

LP1K0910ED

Condición:
Nuevo Precintado de Fábrica
Disponible:
3 piezas
En stock
Actualizado en: 08-11-2024
Oferta de:
GBProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
£43.43
net
LP1K0910ED product image
Schneider Electric

LP1K0910ED

Condición:
Nuevo Precintado de Fábrica
Disponible:
3 piezas
En stock
Actualizado en: 08-11-2024
Oferta de:
ITProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€48.05
net
LP1K0910ED product image
Schneider Electric

LP1K0910ED

Condición:
Nuevo Precintado de Fábrica
Disponible:
3 piezas
En stock
Actualizado en: 09-11-2024
Oferta de:
DEProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€49.50
net
LP1K0910ED product image
Schneider Electric

LP1K0910ED

Condición:
Nuevo Precintado de Fábrica
Disponible:
3 piezas
En stock
Actualizado en: 09-11-2024
Oferta de:
FRProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€60.96
net
LP1K0910ED product image
Schneider Electric

LP1K0910ED

Condición:
Nuevo Precintado de Fábrica
Disponible:
3 piezas
En stock
Actualizado en: 08-11-2024
Oferta de:
ESProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€65.65
net
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€13.23

Environment

Product Certifications
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Ambient Air Temperature For Operation
-25-50 °C
Standards
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Flame Retardance
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Ambient Air Temperature For Storage
-50-80 °C
Ip Degree Of Protection
IP2X
Operating Altitude
6561.68 ft (2000 m) without derating

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1503003EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
ENVEOLI1503003EN
Eu Rohs Directive
Compliant

Complementary

Minimum Switching Current
5 mA for signalling circuit
[Uc] Control Circuit Voltage
48 V DC
[Ue] Rated Operational Voltage
power circuit <= 690 V AC <= 400 Hz || signalling circuit <= 690 V AC <= 400 Hz
Height
58 mm
Average Impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Auxiliary Contact Composition
1 NO
Control Circuit Voltage Limits
operational: 0.8...1.15 Uc (at <50 °C) || drop-out: >= 0.10 Uc (at <50 °C)
[Ith] Conventional Free Air Thermal Current
20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
Mounting Support
plate || rail
Control Circuit Type
DC standard
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption In W
3-3 W 20 °C
Insulation Resistance
> 10 MOhm for signalling circuit
Rated Breaking Capacity
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Irms Rated Making Capacity
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947
Motor Power Kw
2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/60 Hz AC-4 || 4 kW 380...415 V AC 50/60 Hz AC-4 || 4 kW 440/690 V AC 50/60 Hz AC-4
Associated Fuse Rating
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660
Net Weight
0.225 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV
Connections - Terminals
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end || power circuit screw clamp terminals 2 1.5-1.5 mm²flexible with cable end
Pole Contact Composition
3 NO
Utilisation Category
AC-3 || AC-3e || AC-1 || AC-4
[Ie] Rated Operational Current
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Minimum Switching Voltage
17 V for signalling circuit
Maximum Operating Rate
3600 cyc/h
Electrical Durability
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Mechanical Durability
10 Mcycles
Inrush Power In W
3-3 W 20 °C)
Auxiliary Contacts Type
instantaneous 1 NO
Poles Description
3P
Operating Time
30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
Width
45 mm
Tightening Torque
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Overvoltage Category
III
Depth
57 mm
[Ui] Rated Insulation Voltage
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14
[Icw] Rated Short-Time Withstand Current
90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 20 A 50 °C - >= 15 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit
Heat Dissipation
1.3-1.3 W

Specifications

Contactor Application
resistive load || motor control
Product Or Component Type
contactor
Range
TeSys
Device Short Name
LP1K

Modelos CAD

traceparts
traceparts
Descargar