Schneider Electric
LV426950
standard auxiliary contact, ComPact NSXm, circuit breaker status OF/SD, 1 changeover contact type
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
€22.33
1
Payment methods:
A total of 553 Parts In-Stock from 24 Distributors
Product Conditions:
Offer with manufacturer lead time
Ships in:On Request
Best price:
€7.20
Additional Information
- Part Number
- LV426950
- UNSPSC
- 39121522
- Tariff Code
- 8536507000
- Country of Origin
- CN
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Eu Rohs Directive
- Compliant
Specifications
- Range Compatibility
- PowerPact PowerPact B || ComPact ComPact NSXm
- Product Or Component Type
- auxiliary contact
- Signal Contacts Composition
- 1 NO/NC
- Device Application
- breaker status monitoring
- Device Short Name
- SD || OF
Complementary
- Fault Type
- overload || short-circuit
- Auxiliary Connection Terminal
- spring
- [Ith] Conventional Free Air Thermal Current
- 5 A
- Wire Stripping Length
- 8 mm for front connection
- Mounting Mode
- clip-on
- Auxiliary Contacts Type
- standard
- [Ie] Rated Operational Current
- AC-12: 5 A at 24 V AC 50/60 Hz || AC-12: 5 A at 48 V AC 50/60 Hz || AC-12: 5 A at 110...127 V AC 50/60 Hz || AC-12: 5 A at 220/240 V AC 50/60 Hz || AC-12: 5 A at 380/440 V AC 50/60 Hz || AC-12: 5 A at 660/690 V AC 50/60 Hz || AC-15: 5 A at 24 V AC 50/60 Hz || AC-15: 5 A at 48 V AC 50/60 Hz || AC-15: 4 A at 110...127 V AC 50/60 Hz || AC-15: 3 A at 220/240 V AC 50/60 Hz || AC-15: 2.5 A at 380/440 V AC 50/60 Hz || AC-15: 0.1 A at 660/690 V AC 50/60 Hz || DC-12: 5 A at 24 V DC 50/60 Hz || DC-12: 2.5 A at 48 V DC 50/60 Hz || DC-12: 0.6 A at 110 V DC 50/60 Hz || DC-12: 0.3 A at 250 V DC || DC-13: 2.5 A at 24 V DC || DC-13: 1.2 A at 48 V DC || DC-13: 0.35 A at 110 V DC || DC-13: 0.05 A at 250 V DC || DC-14: 1 A at 24 V DC || DC-14: 0.2 A at 48 V DC || DC-14: 0.05 A at 110 V DC || DC-14: 0.03 A at 250 V DC
- Local Signalling
- for open/close ON/OFF indication || for relay trip indicator trip indicator
- Minimum Load
- 2 mA 17 V DC