Schneider Electric
M9F11210
1 / 3
Description
Active Mature
This Multi9 C60N is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 10A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 72mm. The weight is 0.24kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.- Country of Origin
- BG
- Part Number
- M9F11210
- Tariff Code
- 85362010
- EAN
- 3606480576249
- UNSPSC
- 39121603
£37.43
net1
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 103 pcs.In-StockUpdated at: 22-11-2024
- Estimated Delivery:
- On Request
- Condition:
- New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Complementary
- Network Frequency
- 50/60 Hz
- [Ics] Rated Service Breaking Capacity
- 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC 50/60 Hz || 16 kA 75 % EN/IEC 60947-2 - 240 V AC 50/60 Hz || 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC 50/60 Hz || 20 kA 100 % EN/IEC 60947-2 - <= 125 V DC
- Height
- 81 mm
- Contact Position Indicator
- yes
- Earth-Leakage Protection
- separate block
- Mounting Support
- DIN rail
- 9 Mm Pitches
- 4
- Limitation Class
- 3
- Net Weight
- 0.24 kg
- Wire Stripping Length
- 14 mm for top or bottom connection
- Control Type
- toggle
- Connections - Terminals
- tunnel type terminal top or bottom) 1-25 mm² - rigid || tunnel type terminal top or bottom) 1-25 mm² - flexible || tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule
- [Ui] Rated Insulation Voltage
- 500 V AC 50/60 Hz EN/IEC 60947-2
- Mounting Mode
- clip-on
- Electrical Durability
- 10000 cycles
- Mechanical Durability
- 20000 cycles
- Local Signalling
- ON/OFF indication
- [Uimp] Rated Impulse Withstand Voltage
- 6 kVEN/IEC 60947-2
- Color
- Gray
- Width
- 36 mm
- Provision For Padlocking
- padlockable
- Depth
- 72 mm
- Tightening Torque
- 2-2 N.m top or bottom
- Magnetic Tripping Limit
- 8.5 x In +/- 20 % AC || 12 x In +/- 20 % DC
- [Ue] Rated Operational Voltage
- 240 V AC 50/60 Hz between phases || 415 V AC 50/60 Hz between phases || 440 V AC 50/60 Hz between phases || <= 125 V DC
Specifications
- Line Rated Current
- 10 A 50 °C EN/IEC 60947-2
- Curve Code
- C
- Number Of Protected Poles
- 2
- Network Type
- AC || DC
- Standards
- EN/IEC 60947-2
- Product Certifications
- EAC || KC || CCC
- Product Or Component Type
- miniature circuit-breaker
- Product Name
- Multi9 C60
- Utilisation Category
- category A EN/IEC 60947-2
- Range
- Multi9
- Breaking Capacity
- 20 kA Icu <= 125 V DC EN/IEC 60947-2 || 10 kA Icu 415 V AC 50/60 Hz between phases EN/IEC 60947-2 || 20 kA Icu 240 V AC 50/60 Hz between phases EN/IEC 60947-2 || 6 kA Icu 440 V AC 50/60 Hz between phases EN/IEC 60947-2
- Suitability For Isolation
- yes EN/IEC 60947-2
- Poles Description
- 2P
- Device Application
- distribution
- Device Short Name
- C60N
- Trip Unit Technology
- thermal-magnetic
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1304004EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- N/A
- Eu Rohs Directive
- Compliant with Exemptions
- Halogen Content Performance
- Halogen free product
Environment
- Ambient Air Temperature For Operation
- -30-70 °C
- Tropicalisation
- 2 IEC 60068-1
- Ip Degree Of Protection
- IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
- Pollution Degree
- 3 EN/IEC 60947-2
- Ambient Air Temperature For Storage
- -40-80 °C
- Relative Humidity
- 95-95 % 55-55 °C
- Overvoltage Category
- IV
- Heat Dissipation
- 3.6-3.6 W 415 V - 10 A