- Connections - Terminals
- Faston connector
- Ambient Air Temperature For Operation
- -10-70 °C
- Power Range
- 36 W 50 Hz || 37 W 60 Hz
- Condition Of Use
- surrounding environment must be relatively clean || filter must be cleaned and replaced regularly || outside temperature must be 5 °C lower than inside temperature || overfrequent filter replacement should be avoided || flow rates depends on the work point, see ProClima software
- Maximum Pressure
- 158 Pa flow rate 0 m³/h
- Device Composition
- 1 axial motor || 2 protective grille on the front and rear surfaces || 1 filter front of axial motor || 1 outlet grille front || 1 cut-out template || 1 power cord
- Net Weight
- 1.3 kg
- Depth
- external 116 mm
- Cut-Out Dimensions
- 223 x 223 mm
- Ambient Air Temperature For Storage
- -40-70 °C
- Width
- external 248 mm
- Height
- external 268 mm
- Material
- outlet grille injected thermoplastic (ASA PC)
- Ip Degree Of Protection
- IP54
- Color
- outlet grille Gray RAL 7035)
- Line Rated Current
- 0.16-0.16 A 60 Hz || 0.17-0.17 A 50 Hz
- Bearing Type
- ball
- Noise Level
- 55-56 dB