1 / 1
thumbnail

Description

Active Mature
This TM221 controller is part of the Modicon M221 Logic controller range. It has 16 logic I/O and it is supplied with 24V dc. It is supplied with removable screw terminal blocks for connecting the I/O, a removable screw terminal block for connecting the power supply, a button cell backup battery BR2032 and a cable for connecting the analog inputs. M221 logic controllers have three types of integrated communication port, Ethernet, RS 232/RS 485 serial link and USB mini-B programming port. It enables the control of simple machines. The capacity of M221 logic controllers can be enhanced with the Modicon TM3 expansion module offer.
Country of Origin
TW
Part Number
TM221ME16R
Tariff Code
85371091
EAN
3606480611278
UNSPSC
32151705
€223.00
net
1
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
7 pcs.
In-Stock
Updated at: 12-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 273 Parts In-Stock from 33 Distributors
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (40)

TM221ME16R product image
Schneider Electric

TM221ME16R

Condition:
New Factory Sealed
Available:
7 pcs.
In-Stock
Updated at: 12-11-2024
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
18-20 November to United Kingdom
Warranty:
12 months
1
€266.58
€239.92
net
Free Shipping!
TM221ME16R product image
Schneider Electric

TM221ME16R

Condition:
New Factory Sealed
Available:
7 pcs.
In-Stock
Updated at: 12-11-2024
Offer from:
DETrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€289.00
net
TM221ME16R product image
Schneider Electric

TM221ME16R

Condition:
New Factory Sealed
Available:
7 pcs.
In-Stock
Updated at: 12-11-2024
Offer from:
NLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€296.04
net
TM221ME16R product image
Schneider Electric

TM221ME16R

Condition:
New Factory Sealed
Available:
6 pcs.
In-Stock
Updated at: 12-11-2024
Offer from:
ESTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€298.40
net
TM221ME16R product image
Schneider Electric

TM221ME16R

Condition:
New Factory Sealed
Available:
6 pcs.
In-Stock
Updated at: 12-11-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
£324.02
net
Offer with manufacturer lead time
Ships in:On Request
Best price:
€199.36

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1403012EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1403012EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Discrete Input Logic
sink or source (positive/negative)
Data Backed Up
256 kB built-in flash memory backup of application and data
Exct Time For Event Task
60 µs response time
Input Impedance
100 kOhm analog input || 3.4 kOhm input || 4.9 kOhm fast input
Electrical Connection
terminal block, 3 for connecting the 24 V DC power supply || connector, 4 for analogue inputs || mini B USB 2.0 connector for a programming terminal || removable screw terminal block, 10 for inputs || removable screw terminal block, 11 for outputs
Maximum Cable Distance Between Devices
shielded cable <10 m fast input || unshielded cable <30 m output || unshielded cable <30 m digital input || unshielded cable <1 m analog input || shielded cable <3 m fast output
Height
90 mm
Discrete Input Voltage
24 V
Maximum Power Consumption In W
23.3 W 24 V with max number of I/O expansion module) || 4.3 W 24 V without I/O expansion module)
Inrush Current
35 A
Discrete Input Voltage Type
DC
Communication Service
DHCP client || Modbus TCP slave device || Ethernet/IP adapter || Modbus TCP client || Modbus TCP server
Port Ethernet
10BASE-T/100BASE-TX 1 100 m copper cable
Maximum Current Per Output Common
7 A
Transmission Rate
1.2...115.2 kbit/s (115.2 kbit/s by default) 15-15 m RS485 || 1.2...115.2 kbit/s (115.2 kbit/s by default) 3-3 m RS232 || 480 Mbit/s USB
Clock Drift
<= 30 s/month 25-25 °C
Battery Type
BR2032 or CR2032X lithium non-rechargeable
Communication Port Protocol
USB port USB - SoMachine-Network || non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network || Ethernet
Protection Type
without protection 5 A
Marking
CE
Backup Time
1 year 25 °C by interruption of power supply)
Discrete I/O Number
16
Reset Time
1 s
Regulation Loop
adjustable PID regulator up to 14 simultaneous loops
Maximum Number Of I/O Expansion Module
7 (local I/O-Architecture) || 14 (remote I/O-Architecture)
Power Supply Output Current
0.52-0.52 A 5 V expansion bus || 0.46-0.46 A 24 V expansion bus
Net Weight
0.264 kg
Application Structure
1 configurable freewheeling/cyclic master task || 1 cyclic auxiliary task || 8 interrupt tasks
Voltage State 0 Guaranteed
<= 5 V input
Configurable Filtering Time
0 ms input || 3 ms input || 12 ms input
Output Voltage Limits
125 V DC || 277 V AC
Maximum Size Of Object Areas
512 %KW constant words || 255 %C counters || 8000 %MW memory words || 255 %TM timers || 512 %M memory bits
Memory Capacity
256 kB user application and data RAM 10000 instructions || 256 kB internal variables RAM
Conversion Time
1 ms per channel + 1 controller cycle time analog input
Voltage State 1 Guaranteed
>= 15 V input
Function Available
frequency generator || PWM || PLS
Control Signal Type
single phase || A/B || pulse/direction
Supply Voltage Limits
20.4-28.8 V
Integrated Connection Type
USB port mini B USB 2.0 || non isolated serial link serial 1 RJ45 RS232/RS485 || Ethernet RJ45
Execution Time Per Instruction
0.2 µs Boolean
Mechanical Durability
20000000 cycles relay output
Electrical Durability
100000 cycles AC-12, 120 V, 240 VA, resistive || 100000 cycles AC-12, 240 V, 480 VA, resistive || 300000 cycles AC-12, 120 V, 80 VA, resistive || 300000 cycles AC-12, 240 V, 160 VA, resistive || 100000 cycles AC-15, cos phi = 0.35 , 120 V, 60 VA, inductive || 100000 cycles AC-15, cos phi = 0.35 , 240 V, 120 VA, inductive || 300000 cycles AC-15, cos phi = 0.35 , 120 V, 18 VA, inductive || 300000 cycles AC-15, cos phi = 0.35 , 240 V, 36 VA, inductive || 100000 cycles AC-14, cos phi = 0.7 , 120 V, 120 VA, inductive || 100000 cycles AC-14, cos phi = 0.7 , 240 V, 240 VA, inductive || 300000 cycles AC-14, cos phi = 0.7 , 120 V, 36 VA, inductive || 300000 cycles AC-14, cos phi = 0.7 , 240 V, 72 VA, inductive || 100000 cycles DC-12, 24 V, 48 W, resistive || 300000 cycles DC-12, 24 V, 16 W, resistive || 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms) || 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Absolute Accuracy Error
+/- 1 % of full scale analog input
Mounting Support
top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
Local Signalling
for PWR 1 LED (green) || for RUN 1 LED (green) || for module error (ERR) 1 LED (red) || for SD card access (SD) 1 LED (green) || for BAT 1 LED (red) || for I/O state 1 LED per channel (green) || for SL 1 LED (green) || for ACT Ethernet network activity (green) || for Link (Link Status) Ethernet network link (yellow)
Response Time
35 µs turn-off, I2...I5 input || 5 µs turn-on, I0, I1, I6, I7 fast input || 35 µs turn-on, other terminals input || 5 µs turn-off, I0, I1, I6, I7 fast input || 100 µs turn-off, other terminals input || 5 µs turn-on, turn-off, Q0...Q1 output || 50 µs turn-on, turn-off, Q2...Q3 output || 300 µs turn-on, turn-off, other terminals output
Discrete Input Current
7 mA discrete input || 5 mA fast input
Execution Time For 1 Kinstruction
0.3 ms event and periodic task || 0.7 ms other instruction
Analogue Input Resolution
10 bits
Realtime Clock
with
Lsb Value
10 mV
Width
70 mm
Depth
70 mm
Minimum Load
1 mA 5 V DC relay output
Data Storage Equipment
2 GB SD card optional)
Insulation
between input and internal logic 500 V AC || between fast input and internal logic 500 V AC || non-insulated between inputs || between output and internal logic 500 V AC || between output groups 500 V AC || non-insulated between analogue input and internal logic || non-insulated between analogue inputs
Supply
serial 1)serial link supply 5 V, <200 mA
Counting Input Number
4 fast input (HSC mode) 100 kHz 32 bits
Permitted Overload On Inputs
+/- 30 V DC 5 min maximum)analog input || +/- 13 V DC permanent)analog input
Switching Frequency
20 switching operations/minute with maximum load

Specifications

Discrete Output Type
relay normally open
Range Of Product
Modicon M221
Discrete Output Number
8 relay
Product Or Component Type
logic controller
Discrete Output Current
2 A
Discrete Output Voltage
5...125 V DC || 5...250 V AC
Analogue Input Number
2 0...10 V
[Us] Rated Supply Voltage
24 V DC
Discrete Input Number
8 , discrete input IEC 61131-2 Type 1

Environment

Product Certifications
LR || cULus || DNV-GL || RCM || EAC || ABS || CE || UKCA || cULus HazLoc
Resistance To Conducted Disturbances
10 V 0.15...80 MHz IEC 61000-4-6 || 3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL) || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Resistance To Electromagnetic Fields
10 V/m 80 MHz...1 GHz IEC 61000-4-3 || 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3 || 1 V/m 2...2.7 GHz IEC 61000-4-3
Standards
IEC 61131-2 || UL 508 || CAN/CSA C22.2 No. 213 || IACS E10 || ANSI/ISA 12-12-01
Immunity To Microbreaks
10 ms
Storage Altitude
0-3000 m
Pollution Degree
<= 2
Ambient Air Temperature For Operation
-10-55 °C horizontal installation) || -10-35 °C vertical installation)
Shock Resistance
98 m/s² 11 ms
Resistance To Magnetic Fields
30 A/m 50/60 Hz IEC 61000-4-8
Vibration Resistance
3.5 mm 5-8.4 Hz symmetrical rail || 3.5 mm 5-8.4 Hz panel mounting || 1 gn 8.4-150 Hz symmetrical rail || 1 gn 8.4-150 Hz panel mounting
Ambient Air Temperature For Storage
-25-70 °C
Environmental Characteristic
ordinary and hazardous location
Relative Humidity
10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
Ip Degree Of Protection
IP20 with protective cover in place
Resistance To Electrostatic Discharge
8 kV in air IEC 61000-4-2 || 4 kV on contact IEC 61000-4-2
Surge Withstand
2 kV power lines (AC) common mode IEC 61000-4-5 || 2 kV relay output common mode IEC 61000-4-5 || 1 kV I/O common mode IEC 61000-4-5 || 1 kV shielded cable common mode IEC 61000-4-5 || 0.5 kV power lines (DC) differential mode IEC 61000-4-5 || 1 kV power lines (AC) differential mode IEC 61000-4-5 || 1 kV relay output differential mode IEC 61000-4-5 || 0.5 kV power lines (DC) common mode IEC 61000-4-5
Resistance To Fast Transients
2 kV IEC 61000-4-4 power lines) || 2 kV IEC 61000-4-4 relay output) || 1 kV IEC 61000-4-4 I/O) || 1 kV IEC 61000-4-4 Ethernet line) || 1 kV IEC 61000-4-4 serial link)
Operating Altitude
0...6561.68 ft (0...2000 m)
Electromagnetic Emission
conducted emissions 79 dBμV/m QP/66 dBμV/m AV power lines (AC))0.15-0.5 MHz IEC 55011 || conducted emissions 73 dBμV/m QP/60 dBμV/m AV power lines (AC))0.5-300 MHz IEC 55011 || conducted emissions 120...69 dBµV/m QP power lines)10-150 kHz IEC 55011 || conducted emissions 63 dBμV/m QP power lines)1.5-30 MHz IEC 55011 || radiated emissions 40 dBμV/m QP class A 10 m)30-230 MHz IEC 55011 || conducted emissions 79...63 dBμV/m QP power lines)150-1500 kHz IEC 55011 || radiated emissions 47 dBμV/m QP class A 10 m)200-1000 MHz IEC 55011

CAD Models

traceparts
traceparts
Download