Schneider Electric XPSBAT12A1AP

safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw

1 / 5
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays
Manufacturer catalogue image
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays
Manufacturer catalogue image
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays
Manufacturer catalogue image
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays
Manufacturer catalogue image
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays
Manufacturer catalogue image
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays
Schneider Electric XPSBAT12A1AP safety module, Harmony XPS, time delayed output, for Estop, guard, OSSD, 24V AC or DC, screw — Contactors & Relays

Product Description

Lifecycle Status:
This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, RFID safety switch and Safety light curtain. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 control outputs, 2 NO immediate, 3 NO configurable and 1 NC configurable safety output, 1 diagnostic output. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÜV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Basic offers the most optimised solution for applications with hardwired safety modules.
Send Inquiry
Payment methods:

Offer details

Best offer from:
Trusted supplier — Romania, member since 2023, 1–4 employees
Availability:
1 pc.
On Request
Updated at: 22-08-2026
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
The Seller is responsible for shipping the product and invoicing

Specifications

Product Certifications
TÜV || cULus
Ambient Air Temperature For Operation
-25-55 °C
Ip Degree Of Protection
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Standards
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
Ambient Air Temperature For Storage
-25-85 °C
Relative Humidity
5-95 % non-condensing

Available Offers

(4)
XPSBAT12A1AP Schneider Electric, Contactors & Relays

Schneider Electric

Available:
3 pcs.
In-Stock
Updated at: 14-09-2026
Offer from:
Trusted supplier — United States, member since 2023
Warranty:
12 months
XPSBAT12A1AP Schneider Electric, Contactors & Relays

Schneider Electric

Available:
0 pcs.
On Request
Updated at: 11-09-2026
Offer from:
Trusted supplier — Germany, member since 2024
XPSBAT12A1AP Schneider Electric, Contactors & Relays

Schneider Electric

Available:
0 pcs.
On Request
Updated at: 14-09-2026
Offer from:
Trusted supplier — Italy, member since 2021, 10–19 employees
Warranty:
12 months

Access our platform to find more offers

Register now to explore 36 mln offers from verified suppliers worldwide.

  • Compare offers globally
  • Direct supplier contact
  • RFQs, Quotes, and Orders
  • BOM Search
Sign UpFree 14-day trial available
Offer with manufacturer lead time
Directly from the manufacturer - with a confirmed, predictable, and fully transparent delivery time.
Get Quote

Documents

Data Sheet

Datasheet for Schneider Electric XPSBAT12A1AP, including specifications and features.

Download Data Sheet
TracePartsTraceParts

CAD Models

3D CAD model and technical drawings, ready for your design software.

Download CAD Model

Related products

XPSBAC34AP Schneider Electric
XPSBAC34AP
Schneider Electric
This safety relay is designed for monitoring Emergency stop and Guard switch

Market insights

AutomaINSIGHTS analytics dashboard

Get real-time analytics and market data to optimize your purchasing decisions for this component and similar products

  • Real-time stock availability data from 700 MRO distributors in Europe and USA
  • Price analysis by condition (new, used, refurbished) with market median prices
  • Critical component availability monitoring to prevent production downtime
  • Inventory optimization insights based on market supply trends
Get Started