1 / 5
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Description

Active Mature
This Harmony XB4, light block with body/fixing collar isoperates with BA9s bulb. It has 1 x NO + 1 x NC contacts and a metal body and is compatible with Harmony XB4 pilot lights. This light block allows fast and easy replacement and configuration of your signaling units. It is easily installed and replaced on compatible illuminated push button or selector switch units via clip together assembly and connected with simple screw-clamp connections. It enables visual distinction of signaling units via illumination by connected with BA9s bulb. It protects operators from unexpected contact with live circuits thanks to its IP20 protection index. It is designed to fit with a standard 22mm control and signaling units, ensuring compatibility when installing in pre-existing machinery. Its wide range of operating temperatures from -40°C to 55°C allows versatility in usage of product.
Country of Origin
FR
Part Number
ZB4BW065
Tariff Code
85365080
EAN
3389110891157
UNSPSC
39122216
€9.75
net
Shipping from:
€25.00
1
Payment methods:
Best offer from:
ITTrusted Automa.Net Supplier
Availability:
27 pcs.
In-Stock
Updated at: 22-11-2024
Warranty:
12 months
Estimated Delivery:
27 November - 02 December to United Kingdom
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Environment

Product Certifications
UL Listed || CSA || DNV || GL || BV || LROS (Lloyds register of shipping)
Ambient Air Temperature For Operation
-40-70 °C
Standards
IEC 60947-5-5 || JIS C8201-5-1 || CSA C22.2 No 14 || IEC 60947-5-4 || IEC 60947-1 || UL 508 || IEC 60947-5-1 || JIS C8201-1
Shock Resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Vibration Resistance
5 gn 2-500 Hz)IEC 60068-2-6
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I IEC 60536
Protective Treatment
TH

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1808008EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1808008EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Contacts Usage
standard
Terminals Description Iso N°1
(11-12)NC
Operating Force
2 N NC changing electrical state || 2.3 N NO changing electrical state
Short-Circuit Protection
10 A cartridge fuse gG IEC 60947-5-1
Operating Travel
1.5 mm NC changing electrical state) || 2.6 mm NO changing electrical state) || 4.3 mm total travel)
Contacts Material
silver alloy (Ag/Ni)
Positive Opening
with IEC 60947-5-1 appendix K
[Ith] Conventional Free Air Thermal Current
10 A IEC 60947-5-1
Net Weight
0.073 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947-1
Cad Overall Height
47 mm
Device Presentation
basic sub-assemblies
Electrical Durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
[Ui] Rated Insulation Voltage
600 V 3)IEC 60947-1
Signalling Type
steady
Operating Torque
0.05 N.m NO changing electrical state
[Ie] Rated Operational Current
3 A 240 V, AC-15, A600 IEC 60947-5-1 || 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
Mechanical Durability
5000000 cycles
Electrical Reliability
λ < 10exp(-6) 5 V 1 mA in clean environment IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA in clean environment IEC 60947-5-4
Tightening Torque
0.8-1.2 N.m IEC 60947-1
Cad Overall Width
30 mm
Cad Overall Depth
37 mm
Shape Of Screw Head
cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm

Specifications

Range Of Product
Harmony XB4
Light Source
bulb not included
Light Block Supply
direct <2.4 W
Product Or Component Type
complete body/contact assembly and light block
Fixing Collar Material
zamak
Head Type
standard
Connections - Terminals
screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
Contacts Type And Composition
1 NO + 1 NC
Sale Per Indivisible Quantity
1
Contact Operation
slow-break
Device Short Name
ZB4
[Us] Rated Supply Voltage
<= 250 V
Bulb Base
BA 9s

CAD Models

traceparts
traceparts
Download