Wago
2020-5372/1102-953
1 / 3
- Part Number
- 2020-5372/1102-953
- Tariff Code
- 85369010000
- UPC
- 4055143523837
- ETIM
- Group Code : EG000012
- Group Description : Terminal blocks
- Class Description : Sensor/actuator terminal block
- Class Code : EC000900
- Version : 7
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Ratings Per Iec/En
- Ratings per
- IEC/EN 60947-7-1
- Rated current
- 13.5 A
Environmental Requirements
- Processing temperature
- -35 … +85 °C
- Continuous operating temperature
- -60 … +105 °C
Physical Data
- Width
- 7 mm / 0.276 inches
- Height
- 81.1 mm / 3.193 inches
- Depth from upper-edge of DIN-rail
- 52.4 mm / 2.063 inches
Material Data
- Note (material data)
- <a href="https://www.wago.com/us/material-specifications" href="_blank">Information on material specifications can be found here</a>
- Color
- Orange
- Material group
- I
- Insulation material
- Polyamide (PA66)
- Flammability class per UL94
- V0
- Fire load
- 0.279 MJ
- Weight
- 15.991 g
Mechanical Data
- Mounting type
- DIN-35 rail
- Marking level
- Center/side marking
General
- Voltage type 1
- DC
- Nominal voltage
- 24 V
Specifications
- Product Group Code
- 0018
Commercial Data
- Packaging type
- Box
- Country of origin
- DE
- GTIN
- 4055143523837
- Customs tariff number
- 85366990990
Notes
- Note
- According to EN 61984, pluggable connectors without a current interrupting capacity must not be mated or unmated when live or under load. An appropriate end plate must be applied to the carrier terminal blocks after each female plug.
Ratings Per Csa
- Approvals per
- CSA 22.2 No 158
- Rated voltage CSA (Use Group C)
- 24 V
- Rated current CSA (Use Group C)
- 10 A
Power Loss
- Power loss, per pole (potential)
- 0.4338 W
- Rated current IN for specified power loss
- 13.5 A
- Resistance value for specified, current-dependent power loss
- 0.00238 Ω
Connection 1
- Connection technology
- Push-in CAGE CLAMP®
- Actuation type
- Operating tool
- Connectable conductor materials
- Copper
- Nominal cross-section
- 1 mm²
- Solid conductor
- 0.14 … 1.5 mm² / 24 … 16 AWG
- Solid conductor; push-in termination
- 0.5 … 1.5 mm² / 20 … 16 AWG
- Fine-stranded conductor
- 0.14 … 1.5 mm² / 24 … 16 AWG
- Fine-stranded conductor; with insulated ferrule
- 0.14 … 0.75 mm² / 24 … 18 AWG
- Fine-stranded conductor; with ferrule; push-in termination
- 0.5 … 0.75 mm² / 20 … 18 AWG
- Note (conductor cross-section)
- Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
- Strip length
- 9 … 11 mm / 0.35 … 0.43 inches
- Wiring direction
- Front-entry wiring
Ratings Per Ul 1059
- Approvals per
- UL 1059
- Rated voltage UL (Use Group B)
- 300 V
- Rated current UL (Use Group B)
- 15 A
- Rated voltage UL (Use Group D)
- 300 V
- Rated current UL (Use Group D)
- 15 A