Wago
855-9450/2000-1751
1 / 2
- Part Number
- 855-9450/2000-1751
- Tariff Code
- 90303370000
- UPC
- 4055143419222
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Current transformer
- Class Code : EC002048
- Version : 7
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Output (Analog)
- Sensitivity
- 22.5 mV/kA at 50 Hz
- Output signal (max.)
- 30 V
Signal Processing
- Limit frequency
- 177 kHz
Environmental Requirements
- Ambient temperature (operation)
- -40 … +80 °C
- Ambient temperature (storage)
- -40 … +80 °C
- Relative humidity
- ≤ 90% (without condensation)
- Operating altitude (max.)
- 2000 m
Connection Data
- Feedthrough for measurement conductor
- Ø 175 mm
Physical Data
- Cable length
- 4.5 m
Measurement Error
- Accuracy class
- 0.5
- Translation errors (all positions)
- 0.75 %
- Translation errors (note)
- Assuming that a primary conductor with a minimum diameter of 15 mm is used that is routed perpendicular to and in contact with the coil.
Material Data
- Fire load
- 0.000 MJ
- Weight
- 130.000 g
Input
- Measurement range
- 10 A ... 10000 A (up to 4000 A in combination with the recommended WAGO products)
Input Current Transformers
- Primary rated current
- 1000 A
- Rated short-time thermal current Ith
- 300 kA at 50 Hz
- Rated frequency
- 50 … 60 Hz
- Mutual inductance M
- 72.31 nH
Standards And Specifications
- Conformity marking
- CE
- Standards/specifications
- EN 61010-1 || EN 61010-2-32 || EN 61869-1 || EN 61869-2 || EN 61869-6 || EN 61869-10 || UL 61010-1
Mechanical Data
- Mounting type
- Split-core current transformer (suspended)
Specifications
- Product Group Code
- 0029
Commercial Data
- Packaging type
- Bag
- Country of origin
- BG
- GTIN
- 4055143419222
- Customs tariff number
- 90303370000
Notes
- Note
- Rogowski technology allows the coils to measure a wide primary current range of up to 10,000 A without loss of accuracy, because there are no saturation effects. The requirements for standards EN 61869-1, EN 61869-2, EN 61869-6 and EN 61869-10 are only partially met, as there are fundamental differences with current transformers for a Rogowski coil.
Test Voltage
- Voltage for isolation test
- AC 7.4 kV; 50 Hz; 1 min
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther