Schneider Electric

9007FTUB4M12

1 / 1
thumbnail

Description

Active Mature
This product is part of the Nema Limit Switches range. This limit switch is a device that converts a mechanical motion into an electrical control signal. It has a single pole double throw, double break, form Z, snap action contacts. It provides switch actuation of CW and CCW (from left and right). The limit switch has a spring return without operating lever operator and supports the lateral approach. The movement of operating head is rotary. It is a limit switch with a rated voltage of 600V AC and rated operating current of 20A. It is furnished with screw clamp terminals for electrical connection. It is an IP67 and NEMA 1/2/4/12/13 rated product. This limit switch has a fixed body, made of cast zinc. Its dimensions are 57.15mm (width) x 86.61mm (depth) x 118.36mm (height). It weighs 1.13kg. It is suitable for foundry casting applications. The 9007 T/FT mill and foundry for severe duty applications, convertible sequences, 59mm housing, including spring return, maintained and neutral position versions. The 9007 series limit switches are designed to withstand harsh industrial environments and are available in a wide range of options.
Country of Origin
MX
Part Number
9007FTUB4M12
Tariff Code
8536509055
EAN
39122213
UPC
785901702429
UNSPSC
39122213
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 08-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Specifications

Range Of Product
9007
Product Or Component Type
limit switch
Head Type
rotary head
Series Name
severe duty foundry
Sale Per Indivisible Quantity
1
Body Type
fixed
Device Application
universal foundry switch
Device Short Name
9007T/FT

Contractual warranty

Warranty
18 months

Complementary

Maximum Displacement Angle
89 °
Height
4.66-4.66 in
Movement Of Operating Head
rotary
Base Plate Style
style B
Terminals Description Iso N°1
A (left side contact) || B (right side contact)
Short-Circuit Protection
20 A Bussmann class CC KTK-R-21 fuse non-time delay
Tripping Angle
6 °
Fixing Mode
by the body
Contacts Material
silver flashed copper
[Ithe] Conventional Enclosed Thermal Current
20 A
Cable Entry
1 entry for Pg 13.5 DIN 40430
Contact Form
Form Z
Electrical Connection
screw-clamp terminals AWG 22...AWG 12
Net Weight
2.5 lb(US)
Switch Actuation
CW and CCW || from left or right
Function Available
neutral position
Type Of Approach
lateral approach
[Ui] Rated Insulation Voltage
600 V 3)IEC 609470-1 || 600 V 3)UL 508 || 600 V 3)CSA C22.2 No 14
Positive Opening
without
Contact Operation
snap action
Maximum Actuation Speed
130 ft/min with 30° cam angle, levers only || 90 ft/min with 45° cam angle, levers only
Type Of Operator
spring return without operating lever
Body Material
cast zinc
Switch Function
SPDT-DB
[Uimp] Rated Impulse Withstand Voltage
2.5 kV AC for 1 minute CE || 2.2 kV AC for 1 minute UL || 2.64 kV AC for 1 minute CSA
Contact Code Designation
A600, AC (Ue = 600 V) Ie = 5 A NEMA rating designation || A600, AC (Ue = 480 V) Ie = 6.25 A NEMA rating designation || A600, AC (Ue = 240 V) Ie = 12.5 A NEMA rating designation || A600, AC (Ue = 120 V) Ie = 20 A NEMA rating designation || P600, DC (Ue = 600 V) Ie = 0.2 A NEMA rating designation || P600, DC (Ue = 250 V) Ie = 1 A NEMA rating designation || P600, DC (Ue = 120 V) Ie = 5 A NEMA rating designation
Width
2.25 in
Depth
3.41 in
Minimum Torque For Tripping
12 lbf.in
Number Of Poles
1
Repeat Accuracy
+/- 0.004 in linear travel of cam on 1.5 in lever arm
Contact Sequence Number
4

Offer Sustainability

Environmental Disclosure
ENVPEP111160EN
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Not applicable, out of EU RoHS legal scope

Environment

Ambient Air Temperature For Operation
-10-185 °F
Shock Resistance
30 gn 9 ms IEC 60068-2-27
Vibration Resistance
10 gn 10-55 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to IEC 60529
Ambient Air Temperature For Storage
-10-185 °F
Nema Degree Of Protection
NEMA 1 Nema type 250 || NEMA 2 Nema type 250 || NEMA 4 Nema type 250 || NEMA 12 Nema type 250 || NEMA 13 Nema type 250
Electrical Shock Protection Class
class 0 IEC 61140
Protective Treatment
corrosion resistant gray paint

Documents

Data Sheet

Download