Schneider Electric

ATV212W075N4C

1 / 1
thumbnail

Description

Active Mature
Country of Origin
ID
Part Number
ATV212W075N4C
Tariff Code
85044095
EAN
3606480322600
UNSPSC
39122001
Payment methods:
Best offer from:
FRTrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 26-08-2024
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 12 Parts In-Stock from 3 Distributors
Delivery from:
FR
FR
SK
SK
DE
DE
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (2)

ATV212W075N4C product image
Schneider Electric

ATV212W075N4C

Condition:
New Factory Sealed
Available:
10 pcs.
In-Stock
Updated at: 08-11-2024
Offer from:
SKTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
ATV212W075N4C product image
Schneider Electric

ATV212W075N4C

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 08-11-2024
Offer from:
DETrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
€351.91

Specifications

Product Destination
asynchronous motors
Range Of Product
Altivar 212
Product Or Component Type
variable speed drive
Ip Degree Of Protection
IP55
Motor Power Kw
0.75 kW
Phase
3 phase
Line Current
1.4 A 480 V || 1.7 A 380 V
[Us] Rated Supply Voltage
380...480 V - 15...10 %
Communication Port Protocol
BACnet || LonWorks || APOGEE FLN || METASYS N2 || Modbus
Supply Voltage Limits
323-528 V
Product Specific Application
pumps and fans in HVAC
Emc Filter
Class C1 EMC filter integrated
Maximum Horse Power Rating
1 hp
Device Short Name
ATV212
Supply Frequency
50...60 Hz - 5...5 %

Contractual warranty

Warranty
18 months

Complementary

Prospective Line Isc
5 kA
Electrical Connection
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 6-6 mm² / AWG 10
Network Frequency
47.5...63 Hz
Discrete Input Logic
positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Type Of Cable
without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Height
297 mm
Acceleration And Deceleration Ramps
automatic based on the load || linear adjustable separately from 0.01 to 3200 s
Analogue Output Type
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Speed Drive Output Frequency
0.5-200 Hz
Discrete Output Type
configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Transmission Frame
RTU
Torque Accuracy
+/- 15 %
Asynchronous Motor Control Profile
voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio, 2 points || voltage/frequency ratio - Energy Saving, quadratic U/f || flux vector control without sensor, standard || voltage/frequency ratio, 5 points
Maximum Switching Current
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Communication Service
read device identification (43) || write single register (06) || time out setting from 0.1 to 100 s || write multiple registers (16) 2 words maximum || read holding registers (03) 2 words maximum || monitoring inhibitable
Transient Overtorque
120-120 % of nominal motor torque +/- 10 % 60 s
Insulation Resistance
>= 1 mOhm 500 V DC for 1 minute
Response Time
FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Data Format
8 bits, 1 stop, odd even or no configurable parity
Apparent Power
1.6 kVA 380 V
Dielectric Strength
3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
Net Weight
7.5 kg
Type Of Polarization
no impedance
Frequency Resolution
display unit 0.1 Hz || analog input 0.024/50 Hz
Accuracy
+/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Switching Frequency
6...16 kHz adjustable || 12...16 kHz with derating factor
Maximum Transient Current
2.4 A 60 s
Connector Type
1 RJ45 || 1 open style
Analogue Input Number
2
Motor Slip Compensation
adjustable || not available in voltage/frequency ratio motor control || automatic whatever the load
Discrete Output Number
2
Minimum Switching Current
3 mA 24 V DC configurable relay logic
Analogue Output Number
1
Physical Interface
2-wire RS 485
Continuous Output Current
2.2 A 380 V || 2.2 A 460 V
Number Of Addresses
1-247
Tightening Torque
1.3 N.m, 11.5 lb.in L1/R, L2/S, L3/T) || 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Discrete Input Type
F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Speed Range
1-10
Isolation
electrical between power and control
Local Signalling
for DC bus energized 1 LED (red)
Linearity Error
VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Specific Application
HVAC
Output Voltage
<= power supply voltage
Nominal Switching Frequency
12 kHz
Width
215 mm
Transmission Rate
9600 bps or 19200 bps
Braking To Standstill
by DC injection
Depth
192 mm
Protection Type
overheating protection drive || line supply undervoltage drive || against input phase loss drive || thermal protection motor || motor phase break motor || with PTC probes motor || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit drive || against exceeding limit speed drive || line supply overvoltage and undervoltage drive
Supply
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Analogue Input Type
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Sampling Duration
2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Speed Accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
Option Card
communication card LonWorks

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111228EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI111234EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || C-tick || UL || NOM 117
Standards
IEC 61800-3 environments 2 category C1 || EN 61800-5-1 || IEC 61800-3 category C1 || EN 61800-3 || EN 55011 group 1 class B || EN 61800-3 environments 1 category C2 || EN 61800-3 environments 2 category C2 || IEC 61800-5-1 || EN 61800-3 environments 2 category C1 || IEC 61800-3 || EN 61800-3 environments 1 category C3 || EN 61800-3 environments 1 category C1 || IEC 61800-3 environments 2 category C3 || IEC 61800-3 environments 2 category C2 || EN 61800-3 environments 2 category C3 || EN 61800-3 category C1 || IEC 61800-3 environments 1 category C2 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 environments 1 category C1
Electromagnetic Compatibility
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test IEC 61000-4-11
Ambient Air Temperature For Operation
-10-40 °C without derating) || 40-50 °C with derating factor)
Shock Resistance
15 gn 11 ms IEC 60068-2-27
Environmental Characteristic
classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
Marking
CE
Vibration Resistance
1.5 mm 3-13 Hz)EN/IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
Noise Level
48 dB 86/188/EEC
Pollution Degree
2 IEC 61800-5-1
Regulation Loop
adjustable PI regulator
Ambient Air Temperature For Storage
-25-70 °C
Relative Humidity
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Assembly Style
with heat sink
Ip Degree Of Protection
IP55 EN/IEC 61800-5-1 || IP55 EN/IEC 60529
Operating Altitude
3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Operating Position
vertical +/- 10 degree

CAD Models

traceparts
traceparts
Download