1 / 5
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Description

Active Mature
This XCKD compact format (CENELEC EN 50047) limit switch has a thermoplastic variable length roller lever and a Zamak body. This limit switch has a robust Zamak body and head, a modular design allowing easier maintenance and a compact CENELEC EN50047 format. It is ideal for all industrial machines like packaging, materials handling, conveyors, machining, food and beverage. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards and is also RoHS compliant. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head. It has a standard M12 connector, compatible with all existing market sensor cabling.
Country of Origin
ID
Part Number
XCKD2145M12
Tariff Code
85365080
EAN
3389110201161
UNSPSC
39122213
Payment methods:
Best offer from:
GBTrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-10-2024
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
A total of 2 Parts In-Stock from 2 Distributors
Delivery from:
GB
GB
DE
DE
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (1)

XCKD2145M12 product image
Schneider Electric

XCKD2145M12

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 08-11-2024
Offer from:
DETrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Specifications

Movement Of Operating Head
rotary
Range Of Product
Telemecanique Limit switches XC Standard
Fixing Mode
by the body
Type Of Operator
spring return roller lever thermoplastic variable length
Sensor Design
compact
Product Or Component Type
limit switch
Head Material
zamak
Material
metal
Head Type
rotary head
Type Of Approach
lateral approach, 2 directions
Series Name
standard format
Contacts Type And Composition
1 NC + 1 NO
Body Type
fixed
Contact Operation
snap action
Body Material
zamak
Device Short Name
XCKD
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Height
65-65 mm
Terminals Description Iso N°1
(13-14)NO || (21-22)NC
Short-Circuit Protection
4 A cartridge fuse gG
Electrical Connection
male connector M12, 5 pins
[Ithe] Conventional Enclosed Thermal Current
4 A
Net Weight
0.22 kg
[Uimp] Rated Impulse Withstand Voltage
0.8 kV IEC 60664 || 0.8 kV IEC 60947-1
Switch Actuation
by 30° cam
[Ui] Rated Insulation Voltage
60 V 3)IEC 60947-1
Electrical Durability
5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening
with
Contacts Insulation Form
Zb
[Ie] Rated Operational Current
3 A 50 V, AC-15 EN/IEC 60947-5-1 appendix A || 0.27 A 50 V, DC-13 EN/IEC 60947-5-1 appendix A
Positive Opening Minimum Torque
0.25 N.m
Mechanical Durability
10000000 cycles
Maximum Actuation Speed
1.5 m/s
Width
31 mm
Depth
30 mm
Minimum Torque For Tripping
0.1 N.m
Repeat Accuracy
0.1 mm on the tripping points with 1 million operating cycles
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA || CCC
Ik Degree Of Protection
IK06 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN 60204-1 || CSA C22.2 No 14 || UL 508 || EN 60947-5-1 || IEC 60204-1 || IEC 60947-5-1
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I IEC 61140 || class I NF C 20-030
Protective Treatment
TC