Schneider Electric

XCSDMC791L01M8

1 / 1
thumbnail

Description

Active Mature
This XCSDMC Coded Magnetic Safety Switch is designed for use as a safety interlock switch for guard door or protective casings monitoring and position detection on machines with low inertia. It has 2 normally closed staggered contacts in presence of magnet + one Led. It has a compact rectangular design with a 15 centimeter PVC cable connection, allowing for flexible installation. Its B10D reliability data is 50 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Country of Origin
FR
Part Number
XCSDMC791L01M8
Tariff Code
85365080
EAN
3389118000230
UNSPSC
39122213
£176.33
net
1
Payment methods:
Best offer from:
PLTrusted Automa.Net Supplier
Availability:
2 pcs.
In-Stock
Updated at: 17-05-2024
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 5 Parts In-Stock from 3 Distributors
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (3)

XCSDMC791L01M8 product image
Schneider Electric

XCSDMC791L01M8

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 21-10-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
XCSDMC791L01M8 product image
Schneider Electric

XCSDMC791L01M8

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 08-11-2024
Offer from:
DETrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
XCSDMC791L01M8 product image
Schneider Electric

XCSDMC791L01M8

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 21-10-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Specifications

Range Of Product
Telemecanique Safety switches XCS
[Ue] Rated Operational Voltage
24 V DC
Cable Length
0.15 m
Product Or Component Type
coded magnetic switch
Component Name
XCSDMC
Design
rectangular, compact
Material
plastic
Size
51 x 16 x 7 mm
Connector Type
M8
Contacts Type And Composition
2 NC
Contact Operation
staggered
Local Signalling
1 LED
Electrical Connection
connector on flying lead
Approach Directions
3 directions
[Ui] Rated Insulation Voltage
100 V DC
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Maximum [Ie] Rated Operational Current
100 mA
Height
51 mm
Switching Frequency
150 Hz
Short-Circuit Protection
500 mA external cartridge fuse gG (gl)
Switching Capacity In Ma
5...100 mA
[Sar] Assured Tripping Distance
15 mm
Contacts Material
rhodium
Insulation Resistance
1000 MOhm
Resistance Across Terminals
57 Ohm
Net Weight
0.101 kg
[Uimp] Rated Impulse Withstand Voltage
2.5 kV EN/IEC 60947-5-1
Maximum Switching Voltage
100 V DC
[Sa] Assured Operating Distance
5 mm
Cable Material
PVC
Breaking Capacity
3 VA
Safety Reliability Data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Material
thermoplastic PBT
Width
16 mm
Depth
7 mm
Electrical Durability
1200000 cycles
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || UL
Ambient Air Temperature For Operation
-25-85 °C
Standards
UL 508 || EN/ISO 12100 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || EN/IEC 60204-1 || ISO 14119
Shock Resistance
30 gn 11 ms IEC 60068-2-27
Vibration Resistance
10 gn 10-150 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to IEC 60529
Ambient Air Temperature For Storage
-40-85 °C
Electrical Shock Protection Class
class II EN/IEC 61140
Maximum Sensitivity To Magnetic Fields
0.3 mT
Protective Treatment
TH