- Minimum Switching Current
- 10 mA at 20 °C
- Height
- 205-205 mm
- Maximum Load Current
- <= 15 A
- Short-Circuit Protection
- 4 A cartridge fuse gG (gl) || 6 A fast blow
- Minimum Actuation Speed
- 0.01 m/s
- [Ithe] Conventional Enclosed Thermal Current
- 4 A
- Supply Voltage Type
- AC/DC
- Head Material
- zamak
- Signalling Circuit Type
- AC/DC
- Net Weight
- 1.2 kg
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV EN/IEC 60947-5-1
- Maximum Operating Rate
- 10 cyc/mn for maximum durability
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 300 VCSA C22.2 No 14 || 250 V 3)EN/IEC 60947-1
- Positive Opening
- with NC contact
- Load Factor
- 1
- [Ie] Rated Operational Current
- 0.55 A 24 V, DC-13, R300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1
- Minimum Actuator Force For Extraction
- 20 N
- Mechanical Durability
- 30000 cycles
- Maximum Actuation Speed
- 0.5 m/s
- Body Material
- zamak
- Safety Reliability Data
- B10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear
- Width
- 44 mm
- Depth
- 113 mm
- Minimum Switching Voltage
- 17 V
- Maximum Actuator Forcible Withdrawal Rtc
- 3000 N
- Resistance To Mechanical Impact
- 9.6 J against the partition || 6.4 J without partition
- Supply Frequency
- 50/60 Hz
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508