Schneider Electric

XMLK100P2D23

1 / 1
thumbnail

Description

Active Mature
This product is part of the XM range, an offer of electronic pressure sensors. The electronic pressure sensor features a 1/4-18 NPT (male) for fluid connection. It is a pressure switch with a pressure setting range of 0kPa to 689.48kPa, a maximum permissible accidental pressure of 1378.95kPa and 2068.43kPa destruction pressure. It supports 4mA to 20mA, 2-wire analog output signal. It is furnished with 4-pin M12 male connector for electrical connection. It is an electronic pressure sensor with a rated supply voltage of 24V DC (voltage limits 8V to 33V) and a current consumption of <20mA. Its dimensions are 36mm (diameter) x 65.5mm (length). It weighs 0.11kg. It is suitable for monitoring air and fresh water. This product is certified by CSA C22.2 No 14, EAC, RCM and UL 508. It meets CE and EN/IEC 61326-2-3 standards. One of the most comprehensive catalogues of industrial and power pressure sensors on the market. The line of XM Pressure Sensors and Switches (formerly known as OsiSense) combine the latest pressure sensing technology with adaptability to virtually any configuration.
Country of Origin
CH
Part Number
XMLK100P2D23
Tariff Code
90262020
EAN
3389119048804
UNSPSC
39122210
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 08-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Specifications

Pressure Sensor Type
pressure transmitter
Type Of Output Signal
analogue
Range Of Product
Telemecanique Pressure sensors XM
Electrical Connection
1 male connector M12 4 pins
Pressure Sensor Size
100-100 psi
Product Or Component Type
electronic pressure sensors
Type Of Packing
individual
Local Display
without
Pressure Sensor Name
XMLK
Current Consumption
< 20 mA
Fluid Connection Type
1/4" - 18 NPT (male)
Analogue Output Function
4...20 mA, 2-wire
Controlled Fluid
air 0-80 °C) || fresh water 0-80 °C)
Quantity Per Set
set of 1
Electrical Circuit Type
control circuit
[Us] Rated Supply Voltage
24 V DC SELV 8-33 V)

Contractual warranty

Warranty
18 months

Complementary

Accuracy
0.1 % of the measuring range
Diameter
36 mm
[Uimp] Rated Impulse Withstand Voltage
0.5 kV
Repeat Accuracy
+/- 1 % of the measuring range
Drift Of The Zero Point
+/- 0.03 % of measuring range/°K
Electromagnetic Compatibility
electrostatic discharge immunity test EN/IEC 61000-4-2 8 kV air, 6 kV contact || susceptibility to electromagnetic fields EN/IEC 61000-4-3 10 V/m 80...1000 MHz || electrical fast transient/burst immunity test EN/IEC 61000-4-4 2 kV || 1.2/50 µs shock waves immunity test EN/IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm || radiated RF fields EN/IEC 61000-4-6 10 V 0.15...80 MHz || immunity to magnetic fields EN/IEC 61000-4-8 30 A/m 50 Hz
Materials In Contact With Fluid
stainless steel type AISI 303 || nitrile (NBR) || ceramic
Length
65.5 mm
Net Weight
0.11 kg
Scale Type
fixed differential
Mechanical Durability
10000000 cycles
Operating Position
any position
Measurement Accuracy
+/- 1 % of the measuring range
Protection Type
reverse polarity || load short-circuit
Drift Of The Sensitivity
+/- 0.04 % of measuring range/°K
Maximum Permissible Accidental Pressure
200 psi
Destruction Pressure
300 psi
Response Time On Output
< 5 ms
Pressure Setting Range
0-100 psi

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA C22.2 No 14 || RCM || EAC || UL 508
Ambient Air Temperature For Operation
0-80 °C
Standards
CE || EN/IEC 61326-2-3
Shock Resistance
25 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
20 gn 9-2000 Hz) EN/IEC 60068-2-6
Ip Degree Of Protection
IP65 conforming to EN/IEC 60529
Nema Degree Of Protection
NEMA 4
Ambient Air Temperature For Storage
-25-80 °C
Protective Treatment
TC