- Display Accuracy
- <= 1 % of the measuring range
- Electrical Connection
- male connector M12, 4 pins
- Height
- 93 mm
- Accuracy
- <= 1 % of the measuring range
- Linearity Error
- <= 0.5 % of the measuring range
- Type Of Output Signal
- analogue + discrete
- Display Response Time Type
- fast 50 ms || normal 200 ms || slow 600 ms
- Maximum Voltage Drop
- 2 V
- Repeat Accuracy
- <= 0.2 % of the measuring range
- Drift Of The Zero Point
- +/- 0.1 % of measuring range/°C
- Time Delay Range
- 0...50 s in steps of 1 second
- Electromagnetic Compatibility
- susceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3 || immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6 || surge immunity test 1 kV EN/IEC 61000-4-5 || electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4 || electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2
- Maximum Switching Current
- 250 mA
- Adjustable Range Of Switching Point On Falling Pressure
- 0.05-0.97 MPa || 7.25-141 psi || 0.5-9.7 bar
- Operating Position
- any position, but disposals can falsified the measurement in case of upside down mounting
- Materials In Contact With Fluid
- 316L stainless steel || ceramic || fluorocarbon FKM (Viton)
- Net Weight
- 0.19 kg
- Minimum Differential Travel
- 30 kPa || 0.3 bar || 4.35 psi
- Current Consumption
- <= 50 mA
- Contacts Type And Composition
- NO/NC programmable
- Maximum Delay First Up
- 300 ms
- Analogue Output Function
- 4...20 mA
- Scale Type
- fixed differential
- Local Signalling
- for light ON when switch is actuated 1 LED (yellow)
- Mechanical Durability
- 10000000 cycles
- Housing Material
- polyacrylamide || 316L stainless steel
- Measurement Accuracy
- <= 0.6 % of the measuring range
- Protection Type
- short-circuit protection || reverse polarity || overload protection || overvoltage protection
- Adjustable Range Of Switching Point On Rising Pressure
- 0.08-1 MPa || 11.6-145 psi || 0.8-10 bar
- Drift Of The Sensitivity
- +/- 0.03 % of measuring range/°C
- Width
- 41 mm
- Display Type
- 4 digits 7 segments
- Front Material
- polyester
- [Uimp] Rated Impulse Withstand Voltage
- 0.5 kV DC
- Hysteresis
- <= 0.2 % of the measuring range
- Depth
- 42 mm
- Response Time On Output
- <= 10 ms analog output || <= 5 ms discrete output
- Discrete Output Type
- solid state PNP, NO/NC programmable