1 / 5
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Description

Active Mature
This safety relay is designed for monitoring Emergency stop, Antivalent contacts, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain or Two-hand control stations. The safety relay is powered with 48-240V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 1 safety input, 2 ON/OFF configurable pulsed outputs, 1 single changeover safety output , and 1 solid state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLc/Category 1 conforming to ISO 13849-1, SILCL 1 conforming to IEC 62061 and SIL 1 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
Country of Origin
ID
Part Number
XPSUAB31CP
Tariff Code
85364900
EAN
3606489601591
UNSPSC
32151705
£316.03
net
1
Payment methods:
Best offer from:
PLTrusted Automa.Net Supplier
Availability:
2 pcs.
In-Stock
Updated at: 17-05-2024
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 24 Parts In-Stock from 8 Distributors
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (7)

XPSUAB31CP product image
Schneider Electric

XPSUAB31CP

Condition:
New Factory Sealed
Available:
6 pcs.
In-Stock
Updated at: 26-07-2024
Offer from:
HUTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
XPSUAB31CP product image
Schneider Electric

XPSUAB31CP

Condition:
New Factory Sealed
Available:
1 pc.
In-Stock
Updated at: 09-11-2024
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
XPSUAB31CP product image
Schneider Electric

XPSUAB31CP

Condition:
New Factory Sealed
Available:
1 pc.
In-Stock
Updated at: 04-09-2024
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
XPSUAB31CP product image
Schneider Electric

XPSUAB31CP

Condition:
New Surplus
Available:
2 pcs.
In-Stock
Updated at: 21-10-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
XPSUAB31CP product image
Schneider Electric

XPSUAB31CP

Condition:
New Surplus
Available:
2 pcs.
In-Stock
Updated at: 08-11-2024
Offer from:
FRTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
€59.34

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1811003EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1811003EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Number Of Outputs
2 on/off configurable pulsed output
Ambient Air Temperature For Operation
-25-55 °C
Height
100 mm
Mounting Support
35 mm symmetrical DIN rail
Minimum Output Voltage
15 V relay output
Minimum Output Current
10 mA relay output
[Ith] Conventional Free Air Thermal Current
3 A
Input/Output Type
semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
Associated Fuse Rating
6 A gG relay output IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage
4 kV II IEC 60947-1
Net Weight
0.200 kg
Type Of Start
automatic/manual/monitored
Number Of Inputs
1 safety input 24 V DC 5
Input Compatibility
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || two-hand control EN 574/ISO 13851-III A || 3-wire proximity sensors PNP
Power Consumption In Va
6.5 VA 240 V AC 50/60 Hz
[Ie] Rated Operational Current
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 2 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact
Auxiliary Contact Composition
1 C/O
[Ui] Rated Insulation Voltage
250 V 2)IEC 60947-1
Power Consumption In W
2.0 W 48 V DC
Maximum Line Resistance
500 Ohm
Local Signalling
for power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow)
Input Protection Type
internal, electronic
Width
22.5 mm
Depth
120 mm
Synchronisation Time Between Inputs
0.5 s || 2.2 s
Maximum Response Time On Input Open
20 ms

Environment

Product Certifications
TÜV || cULus
Ip Degree Of Protection
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Standards
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
Relative Humidity
5-95 % non-condensing

Specifications

[Us] Rated Supply Voltage
48...240 V AC/DC - 10...10 %
Range Of Product
Harmony Safety Automation
Product Or Component Type
safety module
Safety Module Name
XPSUAB
Connections - Terminals
removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Safety Module Application
for electrical monitoring of two-hand control stations || for application with safety switchover contact || for emergency stop, guard and light curtain monitoring || monitoring antivalent contacts
Safety Reliability Data
MTTFd >= 30 years ISO 13849-1 || Dcavg < 60 % ISO 13849-1 || PFHd = 1177E-09 1/h ISO 13849-1 || HFT = 0 IEC 62061 || PFHd = 1177E-09 1/h IEC 62061 || SFF > 60% IEC 62061 || HFT=0 IEC 61508-1 || PFHd = 1177E-09 1/h IEC 61508-1 || SFF > 60% IEC 61508-1 || type = B IEC 61508-1
Electrical Circuit Type
NC pair || PNP pair || antivalent pair || OSSD pair
Function Of Module
emergency stop monitoring 1-channel wiring || guard monitoring 1-channel wiring || monitoring 1 PNP sensor || monitoring two-hand control station type IIIA || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || proximity sensor monitoring
Safety Level
can reach PL c/category 1 ISO 13849-1 || can reach SILCL 1 IEC 62061 || can reach SIL 1 IEC 61508

CAD Models

traceparts
traceparts
Download