Wago

285-1164

1 / 2
thumbnail
thumbnail
Part Number
285-1164
Tariff Code
85369010000
UPC
4055143424158
ETIM
Group Code : EG000012
Group Description : Terminal blocks
Class Description : Feed-through terminal block
Class Code : EC000897
Version : 7
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Ratings Per Iec/En

Ratings per
IEC/EN 60947-7-1
Nominal voltage (III/3)
1000 V
Rated impulse voltage (III/3)
12 kV
Rated current
353 A
Legend (ratings)
(III / 3) ≙ Overvoltage category III / Pollution degree 3

Ratings Per Iec/En 2

Rated voltage (III/3) 2
1500 V
Rated surge voltage (III/3) 2
12 kV

Environmental Requirements

Processing temperature
-35 … +85 °C
Continuous operating temperature
-60 … +105 °C

Physical Data

Width
32 mm / 1.26 inches
Height from the surface
123 mm / 4.843 inches
Depth
170 mm / 6.693 inches

Material Data

Note (material data)
<a href="https://www.wago.com/us/material-specifications" href="_blank">Information on material specifications can be found here</a>
Color
Blue
Material group
I
Insulation material
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
5.446 MJ
Weight
547.220 g

Mechanical Data

Mounting type
Mounting flange
Marking level
Side marking

General

Voltage type 1
AC/DC
Voltage type 2
DC

Specifications

Product Group Code
0001

Commercial Data

Packaging type
Box
Country of origin
DE
GTIN
4055143424158
Customs tariff number
85369010000

Ratings Per Csa

Approvals per
CSA 22.2 No 158
Rated voltage CSA (Use Group B)
1000 V
Rated current CSA (Use Group B)
310 A
Rated voltage CSA (Use Group C)
1000 V
Rated current CSA (Use Group D)
310 A

Power Loss

Power loss, per pole (potential)
11.2148 W
Rated current IN for specified power loss
353 A
Resistance value for specified, current-dependent power loss
9e-005 Ω

Connection 1

Connection technology
POWER CAGE CLAMP
Actuation type
T-wrench; 8 mm
Connectable conductor materials
Copper
Nominal cross-section
185 mm² / 350 kcmil
Solid conductor
50 … 185 mm² / 1/0 AWG … 350 kcmil
Stranded conductor
50 … 185 mm² / 1/0 AWG … 350 kcmil
Fine-stranded conductor
50 … 185 mm² / 1/0 AWG … 350 kcmil
Fine-stranded conductor; with insulated ferrule
50 … 150 mm² / 1/0 AWG … 300 kcmil
Fine-stranded conductor; with uninsulated ferrule
50 … 185 mm² / 1/0 AWG … 350 kcmil
Strip length
45 … 47 mm / 1.77 … 1.85 inches
Wiring direction
Side-entry wiring

Ratings Per Ul 1059

Approvals per
UL 1059
Rated voltage UL (Use Group B)
600 V
Rated current UL (Use Group B)
310 A
Rated voltage UL (Use Group C)
600 V
Rated current UL (Use Group C)
310 A