Balluff
BID R01K-4M100-M20ZZ0-EP00,2-S92
1 / 1
Description
Non-contact magnetically coded safety switches are outstanding for monitoring guard doors – especially in environments where contamination or dust is expected. The non-contact operating principle means they are insensitive to mechanical play, for example when doors settle or are imprecisely guided. This makes the safety switches easy to install. With separate processing electronics the safety switch can be used for applications up to PLe/SIL 3.- Part Number
- BID R01K-4M100-M20ZZ0-EP00,2-S92
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Specifications
- Dimension
- 26 x 36 x 13 mm
- B10d (EN ISO 13849-1)
- NC at 20% contact load 25 mil. Switching operations
- Approval/Conformity
- CE, cULus, WEEE
- Operating principle
- non-contact (magnetic)
- Approach direction
- vertrical to the active surface
- Life expectancy mechanical
- 100 million Switching operations
- Assured operating distance Sao
- 5 mm
- Assured switch off distance Sar
- 15 mm
- Connection
- Cable with connector, M12x1, 5-pin, 20 cm, PUR
- Ambient temperature
- -25-70 °C
- IP rating
- IP67
- Housing material
- Thermoplastic, glass-fiber reinforced
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther