Honeywell Industrial Automation Spare Parts

Honeywell logo

509 results

E34-208400-R03-SPKIT-NS Honeywell, Power Supply
Honeywell

E34-208400-R03-SPKIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 1 or 2 Phase, 400 A, 120/208-240 V AC

On Request

The Class 3400 Smart Meter (H34) is designed for advanced energy monitoring, featuring dual protocol communications that allow for simultaneous interaction with two energy management systems, including Building Automation Systems (BAS) and Measurement & Verification (M&V) reporting tools. The optional expanded feature package provides integrated load control capabilities and includes two pulse outputs for kWh and kVARh monitoring. With a robust 4-line LCD display equipped with backlighting, this meter ensures visibility and ease of use. Communication options include RS485 and Ethernet protocols, accommodating various industrial and commercial applications. The device’s regulatory approvals include ANSI C12.20 and UL/CUL standards, ensuring compliance and reliability in diverse environments. Its dimensions are 6.5 inches in width, 7.8 inches in height, and a depth of 3.4 inches, along with a weight of 7.28 lbs. Designed for both single and two-phase configurations, the Class 3400 operates with a current capacity of 400 A and input voltage configurations of 120/208-240 V AC. It functions within a temperature range of -4 °F to 122 °F and can handle humidity levels up to 95% non-condensing. The device's accuracy is rated at ±1% across its operational load range, making it suitable for precise electrical usage monitoring.

Available in:
US
Ask for a quote
E32-600200-MBAC-SPKIT-NS Honeywell, Power Supply
Honeywell

E32-600200-MBAC-SPKIT-NS

CLASS 3200 SUBMETER - NO SENSORS, 1 or 2 Phase, 200 A, 347/600 V AC

On Request

The Class 3200 Smart Meter (H32) is equipped with RS-485 communications, facilitating integration with multiple energy monitoring systems. It supports simultaneous communication with two systems, including building automation systems (BAS) and energy monitoring/billing programs, as well as measurement and verification (M&V) reporting tools.This meter is engineered for commercial and industrial electrical usage monitoring, operating across 1 or 2 phases. It features a 4-line LCD display with backlight, and is compliant with regulatory standards such as CE and UL/CUL. With a current capacity of 200 A and a voltage input configuration of 347/600 V AC, it operates efficiently in a temperature range from -4 °F to 122 °F (-20 °C to 50 °C) and can withstand a maximum humidity of 95% non-condensing.The Class 3200 meter is compact, with dimensions of 6.5 in (166 mm) in width, 7.8 in (198 mm) in height, and 3.4 in (86 mm) in depth, weighing 5.1 lbs. Its accuracy is rated at ±1% across the entire load range from 1% to 100% of the rated capacity. This model does not include current sensors, thus is designed for applications with external current measurement requirements.

Available in:
US
Ask for a quote
E34-600100-J04SCS-NS Honeywell, Power Supply
Honeywell

E34-600100-J04SCS-NS

CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 100 A, 347/600 V AC

On Request

The Class 3400 Smart Meter (H34) is engineered for advanced energy monitoring, featuring dual protocol communications that allow simultaneous interaction with two energy monitoring systems. This includes compatibility with Building Automation Systems (BAS) for energy monitoring and billing programs, as well as Measurement and Verification (M&V) reporting tools. The optional expanded feature package delivers built-in load control functionalities and includes two pulse outputs for kWh and kVARh. Its design incorporates a user-friendly 4-line LCD display with backlight for clear visibility. Communication capabilities include RS485 and Ethernet, facilitating remote monitoring and integration. The device operates within a temperature range of -20 °C to 50 °C and supports humidity levels of up to 95% non-condensing. The Class 3400 submeter is compliant with ANSI C12.20 and UL/CUL standards, ensuring reliability in commercial and industrial applications.

Available in:
US
Ask for a quote
E34-12025HVJ06-SPKIT-NS Honeywell, Power Supply
Honeywell

E34-12025HVJ06-SPKIT-NS

3400 Submeter - No Sensors, 1 or 2 Phase, 25 A, High Voltage (120) V AC

On Request

The Class 3400 Smart Meters are designed for advanced energy monitoring in commercial and industrial environments. This model supports both single and two-phase configurations, accommodating current loads of 25 A and high voltage levels of 120 V AC. Notably, it features dual protocol communication, allowing simultaneous connections to two energy monitoring systems, including building automation systems and measurement and verification reporting tools. With a 4-line LCD display equipped with a backlight, users can easily access critical information. The meter supports RS485 and Ethernet communications, enhancing data transmission capabilities. While it does not include current sensors, it offers a split-core type for optional integration. This model meets regulatory standards such as ANSI C12.20 and UL/CUL certifications. It operates effectively within a temperature range of -4 °F to 122 °F and can handle humidity levels of up to 95% non-condensing. Its robust JIC steel enclosure ensures durability in various environments, making it suitable for a range of applications. For detailed load control, an optional expanded feature package is available, which includes two pulse outputs for kWh and kVARh measurement. The accuracy of the meter is rated at ±1% across the full load range, ensuring reliable performance for energy consumption monitoring.

Available in:
US
Ask for a quote
E34-400100-J03XSPKIT Honeywell, General Accessories
Honeywell

E34-400100-J03XSPKIT

CLASS 3400 SUBMETER, 1 or 2 Phase, 100 A, 230/400 V AC

On Request

The Class 3400 (H34) Smart Meter features advanced dual protocol communications, facilitating simultaneous connections to two energy monitoring systems, which may include BAS systems and billing programs alongside M&V reporting tools. This model supports both 1 and 2 phase configurations with a maximum current rating of 100 A, operating at 230/400 V AC.Equipped with a 4-line LCD display, this submeter provides critical data with a backlight for visibility in various lighting conditions. Enhanced functionalities are available through an optional feature package that includes built-in load control capabilities and two pulse outputs for kWh and kVARh measurements. Furthermore, it operates effectively in a wide temperature range, from a minimum of -4 °F (-20 °C) to a maximum of 122 °F (50 °C), with a humidity tolerance of up to 95% non-condensing.Constructed with a JIC Steel enclosure, the meter complies with ANSI C12.20 and UL/CUL regulatory approvals, ensuring reliability and safety in commercial and industrial applications. The accuracy of the device is rated at ±1% over the full load range, making it suitable for precise energy monitoring. The Class 3400 is also equipped with split-core current sensors, providing ease of installation and reliable performance.

Available in:
US
Ask for a quote
E34-480100-R04KIT Honeywell, Power Supply
Honeywell

E34-480100-R04KIT

CLASS 3400 SUBMETER, 3 Phase, 100 A, 277/480 V AC

On Request

The Class 3400 (H34) Smart Meter is engineered to support dual protocol communications, allowing for simultaneous interaction with two energy monitoring systems. This includes integration with Building Automation Systems (BAS) for energy monitoring and billing, as well as Measurement and Verification (M&V) reporting tools.This model comes with an optional expanded feature package that provides built-in load control functionalities and two pulse outputs for kWh and kVARh measurement. The device is equipped with a 4-line large LCD display, enhancing user interface clarity, and supports RS485 and Ethernet communication interfaces.Designed for commercial and industrial applications, the Class 3400 meter offers 38 points of information for monitoring electrical usage. Its accuracy is rated at ±1% across a load range of 1% to 100%. The meter is suitable for 3 or 4 wire input voltage configurations and operates effectively within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) with a maximum humidity tolerance of 95% non-condensing. The enclosure is compliant with NEMA 4X standards, ensuring durability and protection in various environments. This device is classified under ANSI C12.20 and carries UL/CUL regulatory approvals.

Available in:
US
Ask for a quote
E50-12025HVJ03-SPKIT-NS Honeywell, Control & HMI
Honeywell

E50-12025HVJ03-SPKIT-NS

CLASS 5000 SUBMETER - NO SENSORS, 1 or 2 Phase, 25 A, High Voltage (120) V AC

On Request

The Class 5000 (H50) Smart Meters are designed to facilitate advanced dual protocol communications and can simultaneously connect to two energy monitoring systems, such as Building Automation Systems (BAS) for energy auditing and billing or Measurement and Verification (M&V) reporting tools. This model is characterized by a 4-line LCD display with backlight, ensuring clear visibility of data in various lighting conditions. Measuring a compact overall size of 6.5 inches in width, 7.8 inches in height, and 3.4 inches in depth, the unit weighs 5.1 pounds. It operates effectively in a wide temperature range, from a minimum of -4 °F (-20 °C) to a maximum of 122 °F (50 °C), and tolerates humidity levels up to 95% non-condensing. The device supports both single and two-phase configurations and requires a 3 or 4 wire input voltage setup. With an accuracy rating of ±1% across a load range of 1% to 100%, the meter is suitable for commercial and industrial applications, providing 38 points of information to monitor electrical usage. The absence of current sensors allows for a streamlined design, and the split-core current sensor type is compatible for those requiring future upgrades. Communication protocols include BACnet MS/TP and EZ-7 Ethernet, enhancing integration into existing systems. The enclosure type is JIC Steel, ensuring durability in industrial environments.

Available in:
US
Ask for a quote
E34-208200-R06-X-SCS-NS Honeywell, Power Supply
Honeywell

E34-208200-R06-X-SCS-NS

CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 200 A, 120/208-240 V AC

On Request

The Class 3400 (H34) Smart Meters facilitate advanced dual protocol communications, allowing for the simultaneous connection to two energy monitoring systems. This includes integration with building automation systems and energy billing programs, as well as measurement and verification reporting tools.This model features an optional expanded functionality package that provides load control capabilities along with two pulse outputs for kWh and kVARh. The meter is equipped with a large 4-line LCD display and supports both RS485 and Ethernet communication protocols.With an operational accuracy of ±1% across a load range of 1% to 100%, the Class 3400 is suitable for commercial and industrial settings. It operates within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) and can withstand humidity levels up to 95% non-condensing. The meter's enclosure meets NEMA 4X standards, ensuring durability in various environments.Notably, the Class 3400 supports both 3-wire and 4-wire configurations, making it versatile for different applications. Its specifications include a current sensor output of 2 V, with no current sensors included, and it operates at frequencies of 50 Hz or 60 Hz.

Available in:
US
Ask for a quote
E34-400400-J02-X-KIT-NS Honeywell, Power Supply
Honeywell

E34-400400-J02-X-KIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 400 A, 230/400 V AC

On Request

The Class 3400 Smart Meters, designated as H34, feature advanced dual protocol communications, enabling them to interface simultaneously with up to two energy monitoring systems. This includes integration with building automation systems (BAS) for energy monitoring and billing, as well as measurement and verification (M&V) reporting tools.Equipped with an advanced 4-line LCD display with backlighting, this meter supports RS485 and Ethernet communications for versatile connectivity. The optional expanded feature package enhances functionality with built-in load control capabilities and provides two pulse outputs for both kWh and kVARh measurements.Regulatory compliance is assured with approvals such as ANSI C12.20 and UL/CUL. The meter's physical dimensions include an overall width of 6.5 inches (166 mm), height of 7.8 inches (198 mm), and depth of 3.4 inches (86 mm), with a total weight of 7.34 lbs. Operating conditions allow for a minimum ambient temperature of -4 °F (-20 °C) and a maximum of 122 °F (50 °C), with a maximum relative humidity of 95% non-condensing. The device also provides an accuracy rating of ±1% across a load range from 1% to 100% of its rated capacity.

Available in:
US
Ask for a quote
E34-400800-R05KIT Honeywell, Proximity & Inductive Sensors
Honeywell

E34-400800-R05KIT

CLASS 3400 SUBMETER, 3 Phase, 800 A, 230/400 V AC

On Request

The Class 3400 (H34) Smart Meter supports advanced dual protocol communications, allowing for simultaneous interaction with two energy monitoring systems, including building automation systems (BAS) and measurement & verification (M&V) reporting tools. This model features an optional expanded package that includes built-in load control functions and two pulse outputs for kWh and kVARh.Equipped with a large, backlit 4-line LCD display, the device communicates via RS485 and Ethernet interfaces. It adheres to regulatory standards such as ANSI C12.20 and UL/CUL, ensuring compliance and reliability in various environments.The enclosure is rated NEMA 4X, suitable for outdoor applications, and operates effectively in ambient temperatures ranging from -20 °C to 50 °C, with a maximum humidity level of 95% non-condensing. The Class 3400 provides ±1% accuracy across its rated load, making it ideal for monitoring electrical usage in commercial and industrial settings.

Available in:
US
Ask for a quote
E32-208800-JBAC-SPKIT-NS Honeywell, Control & HMI
Honeywell

E32-208800-JBAC-SPKIT-NS

CLASS 3200 SUBMETER - NO SENSORS, 1 or 2 Phase, 800 A, 120/208-240 V AC

On Request

The Class 3200 Smart Meter (H32) supports RS-485 communications and is capable of simultaneous interaction with up to two energy monitoring systems. This includes integration with Building Automation Systems (BAS) for energy monitoring, billing programs, and Measurement & Verification (M&V) reporting tools.With a maximum current rating of 800 A, this meter operates at a voltage range of 120/208-240 V AC, and is suitable for both single and two-phase configurations. The device is compliant with ANSI C12.20 and CE standards, ensuring reliable performance in commercial and industrial settings.Key specifications include a 4-line LCD display with backlight for easy reading, and it operates effectively in ambient temperatures ranging from -4 °F to 122 °F (-20 °C to 50 °C) with a maximum humidity of 95% non-condensing. The Class 3200 meter features an accuracy of ±1% across its rated load range and does not include current sensors, utilizing a split-core type for flexibility in installation.For robust applications, it is housed in a JIC Steel enclosure, and its communication protocols include BACnet MS/TP, making it an excellent choice for energy consumption monitoring.

Available in:
US
Ask for a quote
E34-400400-J05XSPKIT-NS Honeywell, Power Supply
Honeywell

E34-400400-J05XSPKIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 1 or 2 Phase, 400 A, 230/400 V AC

On Request

The Class 3400 (H34) Smart Meter integrates advanced dual protocol communication capabilities, allowing for simultaneous connection to two energy monitoring systems. This functionality includes compatibility with Building Automation Systems (BAS) for energy monitoring, billing, and Measurement & Verification (M&V) reporting tools. The unit features an optional expanded package that offers built-in load control and dual pulse outputs for kWh and kVARh.Displaying information on a large 4-line LCD with backlight, this meter supports RS485 and Ethernet communication protocols. It is designed with an enclosure type of JIC Steel and measures 6.5 inches in width, 7.8 inches in height, and 3.4 inches in depth, weighing 7.34 pounds. Operating within a temperature range of -4°F to 122°F (-20°C to 50°C) and a maximum humidity of 95% non-condensing, it is suitable for various commercial and industrial applications.Regulatory approvals include ANSI C12.20 and UL/CUL certifications, ensuring compliance with industry standards. Notably, this model operates without current sensors, offering a split-core type input with a current rating of 400 A, and an input voltage configuration of 3 or 4 wire, functioning at both 50 Hz and 60 Hz frequencies. The accuracy of the meter is maintained at ±1% across its rated load range, enabling precise monitoring of electrical usage.

Available in:
US
Ask for a quote
E34-400200-R05SCS-NS Honeywell, Power Supply
Honeywell

E34-400200-R05SCS-NS

CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 200 A, 230/400 V AC

On Request

The CLASS 3400 Smart Meter (H34) is designed for advanced energy monitoring applications, featuring dual protocol communications that allow simultaneous interaction with two energy monitoring systems, including Building Automation Systems (BAS) and Measurement and Verification (M&V) reporting tools. This particular model does not include sensors and operates effectively in a three-phase configuration. With an overall width of 6.5 inches (166 mm), height of 7.8 inches (198 mm), and depth of 3.4 inches (86 mm), the meter is housed in a NEMA 4X enclosure, ensuring durability in various environments. The device operates within a temperature range from -4 °F (-20 °C) to 122 °F (50 °C) and can withstand humidity levels of up to 95% non-condensing. Equipped with a 4-line LCD display that features backlighting, the meter provides a clear visualization of critical data. It supports an input voltage configuration of either 3 or 4 wire and operates at both 50 Hz and 60 Hz frequencies. Additionally, the accuracy of the meter is rated at ±1% from 1% to 100% of the rated load, ensuring reliable performance in commercial and industrial applications. This model supports communication protocols such as EZ-7 and BACnet IP, enabling integration into existing energy management systems. It also includes optional functionality for load control and provides two pulse outputs for kWh and kVARh monitoring.

Available in:
US
Ask for a quote
E34-600200-J07-SPSCS-NS Honeywell, Power Supply
Honeywell

E34-600200-J07-SPSCS-NS

CLASS 3400 SUBMETER - NO SENSORS, 1 or 2 Phase, 200 A, 347/600 V AC

On Request

The Class 3400 (H34) Smart Meter is engineered to facilitate advanced dual protocol communications, allowing concurrent interaction with two energy monitoring systems. This capability is essential for applications such as Building Automation System (BAS) energy monitoring and billing programs, as well as Measurement and Verification (M&V) reporting tools. It features an optional expanded package that includes built-in load control functions and two pulse outputs for kWh and kVARh. The device is equipped with a 4-line LCD display that includes a backlight for improved visibility, along with RS485 and Ethernet communication options. Regulatory approvals include ANSI C12.20 and UL/CUL, confirming its compliance with industry standards. The meter has a compact design with overall dimensions of 6.5 inches in width, 7.8 inches in height, and 3.4 inches in depth. It operates effectively in ambient temperatures ranging from -4 °F (-20 °C) to 122 °F (50 °C) and supports a maximum humidity level of 95% non-condensing. Designed for commercial and industrial usage, the Class 3400 meter offers a high accuracy rating of ±1% across the load range from 1% to 100%. Its current measurement capabilities can handle configurations of 3 or 4 wire at a frequency of either 50 Hz or 60 Hz, with a current capacity of 200 A and voltage ratings of 347/600 V AC.

Available in:
US
Ask for a quote
E34-208100-J07SCS Honeywell, Power Supply
Honeywell

E34-208100-J07SCS

CLASS 3400 SUBMETER, 3 Phase, 100 A, 120/208-240 V AC

On Request

The Class 3400 Smart Meters (H34) are equipped with advanced dual protocol communications that facilitate concurrent interactions with up to two energy monitoring systems. These systems may include BAS energy monitoring, billing programs, and/or measurement and verification (M&V) reporting tools. The optional expanded feature package enhances functionality with built-in load control capabilities and provides dual pulse outputs for kWh and kVARh.Featuring a sophisticated 4-line LCD display with backlight, the meter supports RS485 and Ethernet communications. It complies with regulatory standards including ANSI C12.20 and UL/CUL, ensuring reliability in various applications.With an operational temperature range from -20 °C to 50 °C and a maximum humidity of 95% non-condensing, this submeter is suitable for diverse environments. The Class 3400 meter, classified as an advanced KWH/Demand Meter, is fully electronic and is capable of monitoring electrical usage with an accuracy of ±1% across its rated load, making it ideal for commercial and industrial utilization.

Available in:
US
Ask for a quote
E50-400200-J06-N-SCS Honeywell, Power Supply
Honeywell

E50-400200-J06-N-SCS

CLASS 5000 SUBMETER, 3 Phase, 200 A, 230/400 V AC

On Request

The Class 5000 (H50) Smart Meter is engineered for advanced energy management, supporting simultaneous communication with two energy monitoring systems, which can include BAS systems for energy tracking and billing as well as M&V reporting tools. It features a large, four-line LCD display for clear reading and is equipped with both RS485 and Ethernet communications for flexible connectivity.This meter operates within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) and can withstand humidity levels of up to 95% non-condensing. It is compliant with ANSI C12.20 and UL/CUL standards, ensuring high reliability in commercial and industrial settings. The Class 5000 includes three solid-core current sensors, providing accurate readings with an accuracy rating of ±1% across a load range of 1% to 100%.With an overall width of 6.5 inches (166 mm), height of 7.8 inches (198 mm), and a depth of 3.4 inches (86 mm), this unit is housed in a JIC steel enclosure, making it suitable for various installation environments. Its input voltage configuration supports both 3 and 4 wire setups and operates at frequency rates of 50 Hz and 60 Hz. This submeter is classified as a Class 5000 device, providing 38 points of information for detailed electrical usage monitoring.

Available in:
US
Ask for a quote
E50-208200-R08-SPKIT Honeywell, Proximity & Inductive Sensors
Honeywell

E50-208200-R08-SPKIT

CLASS 5000 SUBMETER, 1 or 2 Phase, 200 A, 120/208-240 V AC

On Request

The Class 5000 (H50) Smart Meters are engineered to facilitate advanced dual protocol communications, enabling the simultaneous connection with up to two energy monitoring systems. This includes integration with Building Automation Systems (BAS) for energy monitoring, billing programs, and measurement and verification (M&V) reporting tools. The device features a 4-line LCD display with backlight for easy readability. With dimensions of 6.5 inches in width, 7.8 inches in height, and a depth of 3.4 inches, the meter is designed to fit seamlessly into various environments. It operates effectively within a temperature range from -4 °F to 122 °F and a humidity limit of up to 95% non-condensing. The device adheres to regulatory standards including ANSI C12.20 and CE certifications. This model supports both single-phase and two-phase configurations, with a maximum current rating of 200 A. The current sensors employed are split-core types, and the meter's accuracy is rated at ±1% across a load range from 1% to 100% of its rated capacity. Communication is facilitated through LonWorks TP/FT-10 and Modbus TCP/IP protocols, enhancing its application in commercial and industrial settings.

Available in:
US
Ask for a quote
HVFDSB3B0030G220/U Honeywell, VFDs & Frequency Converters
Honeywell

HVFDSB3B0030G220/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 3 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass

On Request

The variable frequency drive (VFD) with a bypass option is designed to optimize energy usage by controlling the speed of fans and pumps within HVAC systems. This unit operates effectively either as part of a building automation system (BAS) or independently utilizing its internal PID control capabilities. Key features include a user-friendly graphical interface that enhances the commissioning process.The drive is equipped with two contactor bypass functionality, rated for 3 HP at an input voltage of 230 Vac. The Designation Code provides insight into its capabilities, which include an overall width of 12 inches and a height of 37.5 inches, with a depth of 11 inches. The unit weighs 18.2 pounds.It incorporates an EMC filter to minimize electromagnetic interference and supports a continuous output current with overload capabilities. With a maximum ambient temperature of 104 °F and a minimum operating temperature of 14 °F, this drive is suitable for a range of environmental conditions. Furthermore, it features a NEMA 12 enclosure, ensuring protection against dust and indirect water, making it ideal for various indoor applications.

Ask for a quote
E34-600400-J06-SPKIT Honeywell, Power Supply
Honeywell

E34-600400-J06-SPKIT

CLASS 3400 SUBMETER, 1 or 2 Phase, 400 A, 347/600 V AC

On Request

The Class 3400 (H34) Smart Meter facilitates advanced dual protocol communications, allowing for concurrent interaction with two energy monitoring systems, which may include building automation systems (BAS) and measurement and verification (M&V) tools. This meter offers an optional expanded feature package, integrating built-in load control capabilities alongside two pulse outputs for kWh and kVARh monitoring.Equipped with a 4-line LCD display, this device supports RS485 and Ethernet communication protocols, ensuring versatile connectivity options. Regulatory approvals such as ANSI C12.20 and UL/CUL highlight its compliance with industry standards. The meter is compact, with overall dimensions of 6.5 in (166 mm) in width, 7.8 in (198 mm) in height, and a depth of 3.4 in (86 mm), weighing 7.78 lbs.Operating conditions are robust, with a range from -4 °F (-20 °C) to 122 °F (50 °C) and a maximum humidity of 95% non-condensing. Designed for commercial and industrial environments, it features a split-core current sensor type and measures current with an accuracy of ±1% across a load range from 1% to 100% of rated capacity. The input voltage can be configured for 3 or 4 wire systems, with frequency compatibility at 50 Hz or 60 Hz. This meter encompasses 38 points of information for comprehensive monitoring of electrical usage.

Available in:
US
Ask for a quote
E32-400200-RBAC-SPKIT Honeywell, Power Supply
Honeywell

E32-400200-RBAC-SPKIT

CLASS 3200 SUBMETER, 1 or 2 Phase, 200 A, 230/400 V AC

On Request

The Class 3200 (H32) Smart Meters incorporate RS-485 communication capabilities, allowing them to function effectively in various energy monitoring applications. They can connect with multiple energy monitoring systems, including Building Automation Systems (BAS) and tools for measurement and verification (M&V) reporting.Designed for commercial and industrial use, these advanced KWH/Demand meters offer a high level of accuracy, with a performance rating of ±1% from 1% to 100% of the rated load. The enclosure meets NEMA 4X standards, ensuring durability in various environmental conditions. With a frequency range of 50 Hz to 60 Hz, these meters support both single-phase and two-phase configurations, while the split-core current sensors facilitate easy installation.Featuring a 4-line LCD display with backlighting, the Class 3200 provides clear visibility of the 38 points of information related to electrical usage. Operating conditions are optimized for a wide temperature range, from a minimum of -20 °C to a maximum of 50 °C, with a humidity tolerance of up to 95% non-condensing. The meter's overall dimensions include a width of 166 mm, height of 198 mm, and depth of 86 mm, with a weight of 7.33 kg.

Available in:
US
Ask for a quote