Schneider Electric
LC1D18F7TQ
IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, bulk
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Condiciones del producto:
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
Enviar solicitud de precio
Additional Information
- Part Number
- LC1D18F7TQ
- UNSPSC
- 39121529
- Tariff Code
- 8536490065
- Country of Origin
- FR
Environment
- Product Certifications
- CCC || GOST || GL || UL || LROS (Lloyds register of shipping) || DNV || BV || RINA || CSA || UKCA
- Height
- 77 mm
- Standards
- EN/IEC 60947-4-1 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508 || IEC 60335-1
- Climatic Withstand
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Net Weight
- 3.3 kg
- Flame Retardance
- V1 conforming to UL 94
- Ip Degree Of Protection
- IP2X IEC 60529 || IP2X VDE 0106
- Mechanical Robustness
- shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
- Operating Altitude
- 9842.52 ft (3000 m) without derating
- Quantity Per Set
- set of 10
- Fire Resistance
- 850 °C IEC 60695-2-1
- Width
- 45 mm
- Depth
- 86 mm
- Permissible Ambient Air Temperature Around The Device
- -5-60 °C || -40-70 °C at Uc
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1501004
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Circularity Profile
- ENVEOLI1501004
- Eu Rohs Directive
- Compliant
Complementary
- Non-Overlap Time
- 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
- Minimum Switching Current
- 5 mA for control circuit
- Power Dissipation Per Pole
- 0.8 W AC-3 || 2.5 W AC-1 || 0.8 W AC-3e
- Average Impedance
- 2.5 mOhm - Ith 32 A 50 Hz for power circuit
- Auxiliary Contact Composition
- 1 NO + 1 NC
- [Ith] Conventional Free Air Thermal Current
- 10 A (at 60 °C) for control circuit || 32 A (at 60 °C) for power circuit
- Control Circuit Voltage Limits
- 0.3...0.6 Uc 60-60 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc 60-60 °C operational AC 50 Hz || 0.85...1.1 Uc 60-60 °C operational AC 60 Hz
- Mounting Support
- rail || plate
- Control Circuit Type
- AC 50/60 Hz
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Insulation Resistance
- > 10 MOhm for control circuit
- Rated Breaking Capacity
- 300 kA at 440 V for power circuit conforming to IEC 60947
- Irms Rated Making Capacity
- 140 A AC for control circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
- Associated Fuse Rating
- 10 A gG for control circuit conforming to IEC 60947-5-1 || 35 A at <= 690 V coordination type 2 for power circuit || 50 A at <= 690 V coordination type 1 for power circuit
- Inrush Power In Va
- 70-70 VA cos phi 0.75 (at 20 °C)
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947
- Pole Contact Composition
- 3 NO
- Connections - Terminals
- control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminal 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminal 1 1.5-6 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminal 2 1.5-6 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminal 1 1-6 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminal 1 1.5-6 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminal 2 1.5-6 mm² - cable stiffness: flexible without cable end
- Coil Technology
- without built-in bidirectional peak limiting diode suppressor
- Operating Time
- 4...19 ms opening || 12...22 ms closing
- Minimum Switching Voltage
- 17 V for control circuit
- Maximum Operating Rate
- 3600 cyc/h 60 °C
- Tightening Torque
- control circuit 1.7 N.m flat Ø 6 mm || control circuit 1.7 N.m Philips No 2 || power circuit 1.7 N.m flat Ø 6 mm || power circuit 1.7 N.m Philips No 2 || control circuit 1.7 N.m pozidriv No 2 || power circuit 1.7 N.m pozidriv No 2
- Mechanical Durability
- 15000000 cycles
- Compatibility Code
- LC1D
- Hold-In Power Consumption In Va
- 7-7 VA 50/60 Hz cos phi 0.3 (at 20 °C)
- Overvoltage Category
- III
- Maximum Horse Power Rating
- 1 hp at 115 V AC 50/60 Hz for 1 phase motors conforming to UL || 1 hp at 115 V AC 50/60 Hz for 1 phase motors conforming to CSA || 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors conforming to CSA || 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors conforming to UL || 15 hp at 575/600 V AC 50/60 Hz for 3 phase motors conforming to CSA || 15 hp at 575/600 V AC 50/60 Hz for 3 phase motors conforming to UL || 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors conforming to CSA || 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors conforming to UL || 3 hp at 230...240 V AC 50/60 Hz for 1 phase motors conforming to CSA || 3 hp at 230...240 V AC 50/60 Hz for 1 phase motors conforming to UL || 5 hp at 230...240 V AC 50/60 Hz for 3 phase motors conforming to CSA || 5 hp at 230...240 V AC 50/60 Hz for 3 phase motors conforming to UL
- Motor Power Kw
- 10 kW at 500 V AC 50/60 Hz || 10 kW at 660...690 V AC 50/60 Hz || 4 kW at 220...230 V AC 50/60 Hz || 7.5 kW at 380...400 V AC 50/60 Hz || 9 kW at 415...440 V AC 50/60 Hz
- [Ui] Rated Insulation Voltage
- control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-4-1 || power circuit 690 V IEC 60947-4-1
- Heat Dissipation
- 2-3 W at 50/60 Hz for control circuit
- Protective Cover
- with
Specifications
- [Uc] Control Circuit Voltage
- 110 V AC 50/60 Hz
- [Ue] Rated Operational Voltage
- power circuit <= 690 V AC 25...400 Hz
- Range Of Product
- TeSys Deca
- Contactor Application
- resistive load || motor control
- Product Or Component Type
- contactor
- Range
- TeSys || TeSys Deca
- Utilisation Category
- AC-1 || AC-3 || AC-3e
- [Ie] Rated Operational Current
- 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
- Poles Description
- 3P
- Device Short Name
- LC1D
Documentos
Data Sheet
DescargarModelos CAD
traceparts
DescargarOtras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros