Fluke P3113-5
Fluke Calibration P3113-5 Hydraulic Deadweight Testers
Never miss out on the parts you need!
Register now to receive instant notifications soon as they become available.
Register NowBenefits of creating an account.
- Register for instant notifications on part availability
- Get real-time alerts on inventory changes
- Notifications about hte total available quantity and conditions for each product.
The highly accurate, quick and easy to use oil operated P3100 hydraulic deadweight testers are available in single or dual piston formats for increased operating ranges.
Additional information
Part Number | P3113-5 |
---|
Operating Fluid
Mineral oil | Shell spindle oil 22, our reference 55-655, viscosity 40 cs @ 20°C |
---|
Pressure Ranges
Oil operated | Ranges to 20,000 psi (1400 bar) |
---|
Accuracy
Accuracy1 | 1. Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range. |
---|---|
Accuracy1 | ±0.015% of reading (±0.008% optional) |
Weight Increments
Minimum standard weight increments | Up to 500 psi (35 bar): 1 psi (0.1 bar) 500 to 5000 psi (35 to 350 bar): 10 psi (1 bar) 5000 to 20,000 psi (350 to 1400 bar): 20 psi (2 bar) Model P3112: 1 psi (0.1 bar) |
---|---|
Optional fractional weights | Up to 500 psi (35 bar): 0.1 psi (0.01 bar) 500 to 5000 psi (35 to 350 bar): 1 psi (0.1 bar) 5000 to 20,000 psi (350 to 1400 bar): 2 psi (0.2 bar) |
Materials of Construction
Cylinder material | Hardened martensitic steel Tungsten carbide (water above 500 psi, 35 bar) |
---|---|
Weight density | 2.7 g/cm³ |
Thermal coefficients of expansion | Oil piston/cylinder 16.5 ppm/°C Water (above 500 psi, 35 bar) 11 ppm/°C |
Weight density | 7.8 g/cm³ |
Standard weight material | Series 3 non-magnetic austenitic stainless steel |
Piston material | Tungsten carbide with nickel binder Density- 15.0 g/cm³ |
Optional fractional weights | Solution heat treated aluminum |
Options
PressCal software | Windows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments. |
---|---|
Fluids | Instruments can be supplied for use with Skydrol or brake fluids. Due to the aggressive nature of these fluids the standard nitrile seals and the acrylic reservoir tube will be replaced by either Viton or EPDM seals (as applicable) and an aluminum reservoir tube. For these or any other specialty fluid applications, please consult the factory. |
General
Instrument size (W x D x H) | 17.5 x 12 x 8.5 |
---|---|
Mass set weight (typical) | 80 lbs (36 kg) |
Instrument weight | 36 lbs (16 kg) |
O-ring seal materials | Buna N as standard, Viton and EPDM available |
Test port adaptors | 1/8, 1/4, 3/8 and ½ NPT or BSP |
Pump displacement | 4.7 cc per stroke |
Reservoir volume | 150 cc |
Screw press displacement | 5.5 cc |