1 / 1
thumbnail

Description

Operation Upon application of input voltage, the output relay is energized and the ON time begins. At the end of the ON time, the output relay de-energizes and the OFF time begins. At the end of the OFF time, the output is energized and the cycle repeats as long as input voltage is applied. Reset: Removing input voltage resets the output and the sequence.
Part Number
FS590
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Input Voltage (V)
120VAC/DC
Input Tolerance (%)
-15% - 20%
Input AC Line Frequency (Hz)
50/60Hz
Output Load Type
Electromechanical relay
Output Form
DPDT
Output Load Rating (VA)
10A resistive @ 120/240VAC 28VDC; 1/3hp @ 120/240VAC
Flash Rate (fpm)
Adjustable from 10-100 operations/min
On/Off Ratio (%)
≅50%
Isolation Voltage (V)
≥1500V RMS input to output
Polarity
DC units are reverse polarity protected
Operating Temperature
-20° to 60° C (-4° F to 140° F)
Storage Temperature (F/C)
-30° to 85°C (-22°F to 185°F)
Mounting Method
Plug-in socket
Termination Type
Octal 8-pin plug-in
Dimensions
3.62 x 2.39 x 1.78 in. (91.6 x 60.7 x 45.2mm)
Weight (lbs/g)
≌5.8oz (164g)
Sample capable
No

Documents

Data Sheet

Download