Littelfuse

KRDB124

1 / 1
thumbnail

Description

Operation (Delay-on-Break) Input voltage must be applied before and during timing. Upon closure of the initiate switch, the output relay energizes. The time delay begins when the initiate switch is opened. The output remains energized during timing. At the end of the time delay, the output de-energizes. The output will energize if the initiate switch is closed when input voltage is applied. Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output.
Part Number
KRDB124
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Input Voltage (V)
12VDC
Input Tolerance (%)
-15% - 20%
Input DC Ripple (%)
≤10%
Output Type
Isolated relay contacts
Output Form
SPDT
Output Load Rating (VA)
10A resistive @ 125VAC; 5A resistive @ 230VAC and 28VDC; 1/4hp @ 125VAC
Time Delay Type
Microcontroller with watchdog circuitry
Time Delay Range
1 - 100m onboard adjustable
Time Delay Tolerance (%)
±5%
Reset Time (ms)
≤150ms
Initiate Time (ms)
≤40ms
Repeat Accuracy (%)
±0.5% or 20ms whichever is greater
Setpoint vs Ambient Temperature and Operating Voltage (%)
≤ ±5%
Switching Voltage Maximum (V)
250VAC
Insulation Resistance
≥100 MΩ
Isolation Voltage (V)
≥1500V RMS input to output
Circuitry
Encapsulated
Polarity
DC units are reverse polarity protected
Life
Mechanical - 1 x 107; Electrical - 1 x 105
Power Consumption
≤2W
Termination Type
0.25 in. (6.35mm) male quick connect terminals
Mounting Method
Surface mount with one #10 (M5 x 0.8) screw
Operating Temperature
-40° to 60°C (-40°F to 140°F)
Storage Temperature (F/C)
-40° to 85°C (-40°F to 185°F)
Humidity
95% relative non-condensing
Dimensions
2.00 x 2.00 x 1.21 in. (50.8 x 50.8 x 30.7mm)
Weight (lbs/g)
≅2.6oz (74g)
Sample capable
No

Documents

Data Sheet

Download