Littelfuse

LLC14B15AX

1 / 1
thumbnail

Description

Operation Drain (Pump-Down Mode): When the liquid level rises and touches the probe, a fixed time delay begins. This time delay prevents rapid cycling of the output relay and its load. At the end of the time delay, the output relay energizes and remains energized until the liquid level falls below the probe. The output relay then de-energizes and remains de-energized until the liquid again touches the probe. Fill (Pump-Up Mode): When the liquid level falls below the probe, a fixed time delay begins. This time delay prevents rapid cycling of the output relay and its load. At the end of the time delay, the output relay energizes and remains energized until the liquid level rises and touches the probe. The output relay then de-energizes and remains de-energized until the liquid level again falls below the probe.
Part Number
LLC14B15AX
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Input Voltage (V)
120VAC
Input Tolerance (%)
-0.3
Input AC Line Frequency (Hz)
50/60Hz
Output Type
Electromechanical relay
Output Form
Non-isolated SPST and isolated SPDT contacts
Output Load Rating (VA)
10A resistive @ 120/240VAC and 28VDC; 1/3hp @ 120/240VAC
Time Delay Range
15s fixed
Sense Voltage
Low voltage AC between probe and common. Isolated from input and ouput.
Sense Resistance (Ohms)
Adjustable to 250kΩ
Sense Resistance Tolerance
Guaranteed range
Control Type
ON/OFF (single level) resistance sensor with built-in time delay to prevent rapid cycling
Isolation Voltage (V)
≥1500V RMS between input output and probe
Surge Protection
IEEE C62.41-1991 Level A
Circuitry
Printed circuit board is conformal coated to resist moisture and corrosion
Life
Mechanical - 1 x 107; Electrical - 1 x 105
Termination Type
0.25 in. (6.35mm) male quick connect terminals
Mounting Method
0.50 in. (12.7mm) nylon standoffs with three #6 (M3.5 x 0.6) screws (use terminal 5 for probe common)
Operating Temperature
-20° to 55°C (-4°F to 131°F)
Storage Temperature (F/C)
-40° to 80°C (-40°F to 176°F)
Dimensions
3.50 x 2.75 x 2.00 in. (88.9 x 69.9 x 50.9mm)
Weight (lbs/g)
≅8.7oz (247g)

Documents

Data Sheet

Download