Description

Operation (Delay-on-Break) Input voltage must be applied before and during timing. Upon closure of the initiate switch, the output relay energizes. The time delay begins when the initiate switch is opened (trailing edge triggered). The output remains energized during timing. At the end of the time delay, the output de-energizes. The output will energize if the initiate switch is closed when input voltage is applied. Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output.
Part Number
ORB120A160
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Input Voltage (V)
120VAC
Input Tolerance (%)
-20% - 10%
Input AC Line Frequency (Hz)
50/60Hz
Output Type
Electromechanical relay
Output Form
Isolated SPDT or DPDT
Output Load Rating (VA)
10A resistive @ 120/240VAC and 28VDC; 1/3hp @ 120/240VAC
Time Delay Type
Analog circuitry
Time Delay Range
60s fixed
Time Delay Tolerance (%)
±10%
Reset Time (ms)
≤50ms
Initiate Time (ms)
≤70ms
Repeat Accuracy (%)
±2% or 20ms whichever is greater
Setpoint vs Ambient Temperature and Operating Voltage (%)
≤ ±10%
Isolation Voltage (V)
≥1500V RMS input to output
Life
Mechanical - 1 x 107; Electrical - 1 x 105
Power Consumption
2.25W
Termination Type
0.25 in. (6.35mm) male quick connect terminals
Mounting Method
Surface mount with four #6 (M3.5 x 0.6) screw
Operating Temperature
-20° to 65°C (-4°F to 149°F)
Storage Temperature (F/C)
-30° to 85°C (-22°F to 185°F)
Weight (lbs/g)
≅2.7oz (77g)
Sample capable
No

Documents

Data Sheet

Download