Littelfuse
THD2C420
1 / 1
Description
Operation (Interval) Upon application of input voltage, the time delay begins. The output energizes during the time delay. At the end of the time delay, the output de-energizes and remains de-energized until input voltage is removed. Reset: Removing input voltage resets the time delay and the output.- Part Number
- THD2C420
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Specifications
- Input Voltage (V)
- 120VAC
- Input Tolerance (%)
- ±20%
- Input AC Line Frequency (Hz)
- 50/60Hz
- Output Type
- Solid state
- Output Form
- NO closed during timing
- Output Load Rating (VA)
- 20A steady state 200A inrush
- Minimum Output Load Current (A)
- 100mA
- Output Voltage Drop (V)
- ≅2.5V @ rated current
- Time Delay Range
- 0.1 - 10s externally adjustable
- Time Delay Tolerance (%)
- ≤±1%
- Reset Time (ms)
- ≤150ms
- Repeat Accuracy (%)
- ±0.5% or 20ms whichever is greater
- Setpoint vs Ambient Temperature and Operating Voltage (%)
- ≤ ±2%
- Open State Leakage Current (A)
- ≅5mA @ 230VAC
- Insulation Resistance
- ≥100 MΩ
- Dielectric Breakdown
- ≥2000V RMS terminals to mounting surface
- Circuitry
- Encapsulated
- Termination Type
- 0.25 in. (6.35mm) male quick connect terminals
- Mounting Method
- Surface mount with one #10 (M5 x 0.8) screw
- Operating Temperature
- -40° to 60°C (-40°F to 140°F)
- Storage Temperature (F/C)
- -40° to 85°C (-40°F to 185°F)
- Humidity
- 95% relative non-condensing
- Dimensions
- 2.00 x 2.00 x 1.51 in. (50.8 x 50.8 x 38.4mm)
- Weight (lbs/g)
- ≅3.9oz (111g)
- Sample capable
- No
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther