Offer Description

The MS132-12 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 12.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.MS132-12 Manual Motor Starter 8.0 12 A ABB

Product Description

The MS132-12 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 12.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.

Product Details

Brand
ABB
Country of Origin
DE
Part Number
1SAM350000R1012
Tariff Code
85362010
EAN
4013614400124
UPC
40136144001240
UNSPSC
39121521
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Motor protection circuit-breaker
Class Code : EC000074
Version : 7
$171.59
excl. tax
Free Shipping!

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 16-07-2025
Warranty:
12 months
Estimated Delivery:
24-29 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Dimensions

Product Net Width
45 mm
Product Net Height
97.8 mm
Product Net Depth / Length
86.55 mm
Product Net Weight
0.31 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)
(230 V AC) 100 kA(250 V DC) 3 Poles in Series 10 kA(400 V AC) 100 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 3 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(230 V AC) 100 kA(400 V AC) 100 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)
180 A
Setting Range
8.0 ... 12 A
Rated Operational Power AC-3 (Pe)
(400 V) Three Phase 5.5 kW
Rated Operational Power AC-3e (Pe)
(400 V) Three Phase 5.5 kW
Rated Operational Voltage
Main Circuit 690 V ACMain Circuit 250 V DC
Rated Operational Current (Ie)
12 A
Rated Operational Current AC-3 (Ie)
12 A
Rated Operational Current AC-3e (Ie)
12 A
Rated Operational Current DC-5 (Ie)
12 A
Rated Frequency (f)
Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
at Rated Operating Conditions per Pole 1.0 ... 2.3 W
Number of Poles
3
Conventional Free-air Thermal Current (Ith)
Main Circuit 12 A
Degree of Protection
Housing IP20Main Circuit Terminals IP10
Pollution Degree
3
Electrical Durability
50000 cycle
Mechanical Durability
100000 cycle
Terminal Type
Screw Terminals
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²Flexible 1/2x 1 ... 2.5 mm²Flexible 1/2x 2.5 ... 6 mm²Rigid 1/2x 1 ... 2.5 mm²Rigid 1/2x 2.5 ... 6 mm²
Tightening Torque
Main Circuit 2 N·m
Wire Stripping Length
Main Circuit 10 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance
Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
Actuator Type
Rotary Handle
Contact Position Indication
ON / OFF / TRIP
Standards
IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1
Remarks
UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Classifications

Object Classification Code
F
ETIM 4
EC000074 - Motor protective circuit-breaker
ETIM 5
EC000074 - Motor protective circuit-breaker
EClass
V11.0 : 27370401
IDEA Granular Category Code (IGCC)
4731 >> Manual Starters
E-Number (Finland)
3705996
E-Number (Sweden)
3112131

Environmental

Ambient Air Temperature
Around the Enclosure 0 ... +40 °COperation -25 ... +70 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6
5g / 3 ... 150 Hz
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Technical UL/CSA

Short-Circuit Current Rating (SCCR)
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Horsepower Rating UL/CSA
(200 V AC) Three Phase 3 Hp(208 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 3 Hp(440 ... 480 V AC) Three Phase 7.5 Hp(550 ... 600 V AC) Three Phase 10 Hp
Full Load Amps Motor Use
(200 V AC) Three Phase 11 A(208 V AC) Three Phase 10.6 A(220 ... 240 V AC) Three Phase 9.6 A(440 ... 480 V AC) Three Phase 11 A(550 ... 600 V AC) Three Phase 11 A
Locked Rotor Amps
(200 V AC) Three Phase 73.6 A(208 V AC) Three Phase 71 A(220 ... 240 V AC) Three Phase 64 A(440 ... 480 V AC) Three Phase 63.5 A(550 ... 600 V AC) Three Phase 64.8 A
General Use Rating UL/CSA
(600 V AC) 12 A
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 16-8 AWGStranded 1/2x 16-8 AWG
Tightening Torque UL/CSA
Main Circuit 18 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85362010

Related products

2CDS283001R0971 ABB, Power Supply
2CDS283001R0971
ABB
S203P-D1.6 Miniature Circuit Breaker - 3P - D - 1.6 A
1SDA068501R1 ABB, Other
1SDA068501R1
ABB
XT4S 160 Ekip LSI In=40A 4p F F
1SNA290452R0400 ABB, Other
1SNA290452R0400
ABB
BJE762.5 Jumper Bars - Orange
1SNK158181R0000 ABB, Other
1SNK158181R0000
ABB
MC612PA Terminal Block Markers pre-printed : W3 (x100) Horizontal
1SNK160022R0000 ABB, Other
1SNK160022R0000
ABB
MC812PA Terminal Block Markers pre-printed : 11->20 (x10) Vertical
1SNK169012R0000 ABB, Other
1SNK169012R0000
ABB
MC812PA Terminal Block Markers pre-printed : U1-U2-U3-V1-V2-V3-W1-W2-W3 (x10) + U1 (x10) Vertical
1SNK926305R0000 ABB, Other
1SNK926305R0000
ABB
JB26-5 Jumper Bar
BES300-30 ABB, Other
BES300-30
ABB
BUSBAR KIT,PH-PH,A210-A300
CAL16-11P ABB, Other
CAL16-11P
ABB
AUXILIARY CONTACT BLOCK
CEPY1-1002 ABB, Other
CEPY1-1002
ABB
CP,ENCL,YEL,P-P 40MM RED 2NC
EX05ASC1 ABB, Other
EX05ASC1
ABB
3/4NPT BRASS DC GLAND 8.5-16MM
EXS05MSC1 ABB, Other
EXS05MSC1
ABB
M25 S/S316 D/C GLAND 6-12MM
TF6540 ABB, Motors
TF6540
ABB
TOL,AF40-65,CLASS-10,30-40A