Need more information?
ABB 1SAM360000R1005MO132-1.0 Manual Motor Starter Magnetic Only 1 A
Offer Description
The MO132-1.0 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 1.00 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.MO132-1.0 Manual Motor Starter Magnetic Only 1 A ABB 1SAM360000R1005
Product Description
Product Details
- Brand
- ABB
- Country of Origin
- DE
- Part Number
- 1SAM360000R1005
- Tariff Code
- 85362010
- EAN
- 4013614400209
- UNSPSC
- 39121521
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Motor protection circuit-breaker
- Class Code : EC000074
- Version : 7
Offer details
- Best offer from:
Trusted Automa.Net Supplier
- Availability:
- 3 pcs.In-StockUpdated at: 18-07-2025
- Warranty:
- 12 months
- Estimated Delivery:
- 25-30 July to United States
- Condition:
- New Factory Sealed
Are you a Supplier?
Join 650 suppliers, sell to 3500+ verified buyers.
Policies and Information
Shipping Information
Return & Refund Policies
Secure Payment Process
Warranty Policies
Dimensions
- Product Net Width
- 45 mm
- Product Net Height
- 90 mm
- Product Net Depth / Length
- 86.75 mm
- Product Net Weight
- 0.215 kg
Technical
- Rated Service Short-Circuit Breaking Capacity (Ics)
- (230 V AC) 100 kA(400 V AC) 100 kA(440 V AC) 100 kA(500 V AC) 100 kA(690 V AC) 100 kA
- Rated Ultimate Short-Circuit Breaking Capacity (Icu)
- (230 V AC) 100 kA(400 V AC) 100 kA(440 V AC) 100 kA(500 V AC) 100 kA(690 V AC) 100 kA
- Rated Instantaneous Short-Circuit Current Setting (Ii)
- 12.5 A
- Setting Range
- None
- Rated Operational Power AC-3 (Pe)
- (400 V) Three Phase 0.25 kW
- Rated Operational Power AC-3e (Pe)
- (400 V) Three Phase 0.25 kW
- Rated Operational Voltage
- Main Circuit 690 V AC
- Rated Operational Current (Ie)
- 1 A
- Rated Operational Current AC-3 (Ie)
- 1 A
- Rated Operational Current AC-3e (Ie)
- 1 A
- Rated Frequency (f)
- Main Circuit 50 HzMain Circuit 60 Hz
- Rated Impulse Withstand Voltage (Uimp)
- Main Circuit 6 kV
- Rated Insulation Voltage (Ui)
- 690 V
- Power Loss
- at Rated Operating Conditions per Pole 1.7 W
- Number of Poles
- 3
- Conventional Free-air Thermal Current (Ith)
- Main Circuit 1 A
- Degree of Protection
- Housing IP20Main Circuit Terminals IP10
- Pollution Degree
- 3
- Electrical Durability
- 50000 cycle
- Mechanical Durability
- 100000 cycle
- Terminal Type
- Screw Terminals
- Connecting Capacity Main Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²Flexible 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²
- Tightening Torque
- Main Circuit 0.8 ... 1.2 N·m
- Wire Stripping Length
- Main Circuit 9 mm
- Recommended Screw Driver
- Pozidriv 2
- Mounting Position
- 1 ... 6
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Minimum Mounting Distance
- Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
- Actuator Type
- Rotary Handle
- Contact Position Indication
- ON / OFF / TRIP
- Standards
- IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1
- Remarks
- For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Classifications
- Object Classification Code
- F
- ETIM 4
- EC000074 - Motor protective circuit-breaker
- ETIM 5
- EC000074 - Motor protective circuit-breaker
- EClass
- V11.0 : 27370401
- IDEA Granular Category Code (IGCC)
- 4731 >> Manual Starters
- E-Number (Finland)
- 3705883
- E-Number (Sweden)
- 3110033
Environmental
- Ambient Air Temperature
- Around the Enclosure 0 ... +40 °COperation -25 ... +60 °CStorage -50 ... +80 °C
- Ambient Air Temperature Compensation
- No
- Maximum Operating Altitude Permissible
- 2000 m
- Resistance to Shock acc. to IEC 60068-2-27
- 11 ms Pulse 25g
- Resistance to Vibrations acc. to IEC 60068-2-6
- 5g / 3 ... 150 Hz
- RoHS Status
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Technical UL/CSA
- Short-Circuit Current Rating (SCCR)
- Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
- Maximum Operating Voltage UL/CSA
- Main Circuit 600 V AC
- Horsepower Rating UL/CSA
- (550 ... 600 V AC) Three Phase 0.5 Hp
- Full Load Amps Motor Use
- (200 V AC) Three Phase 1 A(208 V AC) Three Phase 1 A(220 ... 240 V AC) Three Phase 1 A(440 ... 480 V AC) Three Phase 1 A(550 ... 600 V AC) Three Phase 1 A
- Locked Rotor Amps
- (200 V AC) Three Phase 6 A(208 V AC) Three Phase 6 A(220 ... 240 V AC) Three Phase 6 A(440 ... 480 V AC) Three Phase 6 A(550 ... 600 V AC) Three Phase 6 A
- General Use Rating UL/CSA
- (600 V AC) 1 A
- Connecting Capacity Main Circuit UL/CSA
- Flexible 1/2x 16-12 AWGStranded 1/2x 16-12 AWG
- Tightening Torque UL/CSA
- Main Circuit 10 in·lb
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85362010