ABB 1SBL297001R1300AF38-30-00-13 100-250V50/60HZ-DC Contactor

1 / 1
1SBL297001R1300 ABB, Contactors
Reference Image - Not actual item!

Product Description

The AF38-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 18.5 kW / 400 V AC (AC-3) or 25 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Product Details

Brand
ABB
Country of Origin
FR
Part Number
1SBL297001R1300
Tariff Code
85364900
EAN
3471523111530
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7
$276.86
excl. tax
Supplier Price
£218.00
Shipping from:
£75.00

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
5 pcs.
In-Stock
Updated at: 17-07-2025
Warranty:
12 months
Estimated Delivery:
28-31 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Check other offers

New Factory Sealed
$233.77
A total of 8 Parts In-Stock from 2 Distributors

Policies and Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Available Offers

(1)
1SBL297001R1300 ABB, Contactors

ABB

Available:
3 pcs.
In-Stock
Updated at: 16-07-2025
Offer from:
Trusted Automa.Net Supplier
Estimated Delivery:
24-29 July to United States
Warranty:
12 months
$233.77
excl. tax
Free Shipping!

Dimensions

Product Net Width
45 mm
Product Net Depth / Length
86 mm
Product Net Height
86 mm
Product Net Weight
0.31 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 50 A(690 V) 60 °C 42 A(690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 38 A(440 V) 60 °C 38 A(500 V) 60 °C 33 A(690 V) 60 °C 24 A(380 / 400 V) 60 °C 38 A(220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 38 A(440 V) 60 °C 38 A(500 V) 60 °C 33 A(690 V) 60 °C 24 A(380 / 400 V) 60 °C 38 A(220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)
(400 V) 18.5 kW(415 V) 18.5 kW(440 V) 22 kW(500 V) 22 kW(690 V) 22 kW(380 / 400 V) 18.5 kW(220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)
(415 V) 18.5 kW(440 V) 22 kW(500 V) 22 kW(690 V) 22 kW(380 / 400 V) 18.5 kW(220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A(110 V) 2 Poles in Series, 60 °C 42 A(110 V) 2 Poles in Series, 70 °C 37 A(110 V) 3 Poles in Series, 40 °C 50 A(110 V) 3 Poles in Series, 60 °C 42 A(110 V) 3 Poles in Series, 70 °C 37 A(220 V) 3 Poles in Series, 40 °C 50 A(220 V) 3 Poles in Series, 60 °C 42 A(220 V) 3 Poles in Series, 70 °C 37 A(72 V) 1-Pole, 40 °C 50 A(72 V) 1-Pole, 60 °C 42 A(72 V) 1-Pole, 70 °C 37 A(72 V) 2 Poles in Series, 40 °C 50 A(72 V) 2 Poles in Series, 60 °C 42 A(72 V) 2 Poles in Series, 70 °C 37 A(72 V) 3 Poles in Series, 40 °C 50 A(72 V) 3 Poles in Series, 60 °C 42 A(72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A(110 V) 2 Poles in Series, 60 °C 42 A(110 V) 2 Poles in Series, 70 °C 37 A(110 V) 3 Poles in Series, 40 °C 50 A(110 V) 3 Poles in Series, 60 °C 42 A(110 V) 3 Poles in Series, 70 °C 37 A(220 V) 3 Poles in Series, 40 °C 50 A(220 V) 3 Poles in Series, 60 °C 42 A(220 V) 3 Poles in Series, 70 °C 37 A(72 V) 1-Pole, 40 °C 50 A(72 V) 1-Pole, 60 °C 42 A(72 V) 1-Pole, 70 °C 37 A(72 V) 2 Poles in Series, 40 °C 50 A(72 V) 2 Poles in Series, 60 °C 42 A(72 V) 2 Poles in Series, 70 °C 37 A(72 V) 3 Poles in Series, 40 °C 50 A(72 V) 3 Poles in Series, 60 °C 42 A(72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A(110 V) 2 Poles in Series, 60 °C 42 A(110 V) 2 Poles in Series, 70 °C 37 A(110 V) 3 Poles in Series, 40 °C 50 A(110 V) 3 Poles in Series, 60 °C 42 A(110 V) 3 Poles in Series, 70 °C 37 A(220 V) 3 Poles in Series, 40 °C 25 A(220 V) 3 Poles in Series, 60 °C 25 A(220 V) 3 Poles in Series, 70 °C 25 A(72 V) 1-Pole, 40 °C 25 A(72 V) 1-Pole, 60 °C 25 A(72 V) 1-Pole, 70 °C 25 A(72 V) 2 Poles in Series, 40 °C 50 A(72 V) 2 Poles in Series, 60 °C 42 A(72 V) 2 Poles in Series, 70 °C 37 A(72 V) 3 Poles in Series, 40 °C 50 A(72 V) 3 Poles in Series, 60 °C 42 A(72 V) 3 Poles in Series, 70 °C 37 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 10 mm²Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²Flexible with Insulated Ferrule 2x 1.5 ... 4 mm²Rigid Solid 1/2x 2.5 ... 4 mm²Rigid Stranded 1/2x 2.5 ... 10 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mmMain Circuit 14 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type
Screw Terminals

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3706309
E-Number (Sweden)
3211386

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6
5 ... 300 Hz 4 g closed position / 2 g open position
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 gOpen, Shock Direction: B1 5 gShock Direction: A 30 gShock Direction: B2 15 gShock Direction: C1 25 gShock Direction: C2 25 g
RoHS Status
Following EU Directive 2011/65/EU

Technical UL/CSA

Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp(200 ... 208 V AC) Three Phase 10 hp(220 ... 240 V AC) Three Phase 10 hp(240 V AC) Single Phase 5 hp(440 ... 480 V AC) Three Phase 25 hp(550 ... 600 V AC) Three Phase 30 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 14-10 AWGRigid Stranded 1/2x 14-8 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lbMain Circuit 22 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900

Related products

KA2-2025 ABB, Lighting
KA2-2025
ABB
KA2-2025 LED bulb
KT3112 ABB, Other
KT3112
ABB
K-KT3112 Main Distribution Board, 100 mm x 200 mm x 600 mm
1SNA519004R0000 ABB, Other
1SNA519004R0000
ABB
E-RGW6 End Section - Grey
1SDA073908R1 ABB, Other
1SDA073908R1
ABB
E1.2 W FP Iu=1600 4p HR HR
1SL0830A00 ABB, PLCs
1SL0830A00
ABB
IP44-55-65; Rectangular; IP44-IP55-IP65 junction boxes in thermoplastic material
2CMA167566R1000 ABB, PLCs
2CMA167566R1000
ABB
Surface inlet, 6h, 63A, IP44, 3P+N+E
2TLA050210R0830 ABB, Other
2TLA050210R0830
ABB
126M ROPE KIT, GALV. W/ALLEN KEY
1SDA054915R1 ABB, Other
1SDA054915R1
ABB
AUX-C T4-T5-T6 3Q 1SY 24 Vdc
1SDA071389R1 ABB, Circuit Breakers
1SDA071389R1
ABB
E1.2C 800 Ekip Hi-Touch LSIG 4p F F
1SDA071712R1 ABB, Circuit Breakers
1SDA071712R1
ABB
E2.2H 2500 Ekip Dip LSI 4p F HR