Need more information?

Call us at:+48 17 778 34 19

ABB 1SFL577001R7011AF400-30-11 100-250V 50/60Hz / 100-250V DC Contactor

1 / 2
1SFL577001R7011 ABB, PLCs
Reference Image - Not actual item!
1SFL577001R7011 ABB, PLCs
1SFL577001R7011 ABB, PLCs
1SFL577001R7011 ABB, PLCs

Offer Description

The AF400-30-11-70 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 350 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 550 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.AF400-30-11 100-250V 50/60Hz / 100-250V DC Contactor ABB 1SFL577001R7011

Product Description

The AF400-30-11-70 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 350 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 550 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Product Details

Brand
ABB
Country of Origin
SE
Part Number
1SFL577001R7011
Tariff Code
85364900
EAN
7320500217665
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7
$1,217.09
excl. tax
Free Shipping!

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 17-07-2025
Warranty:
12 months
Estimated Delivery:
25-30 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Dimensions

Product Net Width
186 mm
Product Net Depth / Length
216 mm
Product Net Height
278 mm
Product Net Weight
10.6 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 600 A(1000 V) 55 °C 500 A(1000 V) 70 °C 400 A(690 V) 40 °C 600 A(690 V) 55 °C 500 A(690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 400 A(440 V) 55 °C 400 A(500 V) 55 °C 400 A(690 V) 55 °C 350 A(1000 V) 55 °C 155 A(380 / 400 V) 55 °C 400 A(220 / 230 / 240 V) 55 °C 400
Rated Operational Power AC-3 (Pe)
(415 V) 220 kW(440 V) 220 kW(500 V) 250 kW(690 V) 315 kW(1000 V) 220 kW(380 / 400 V) 200 kW(220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3500 A
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 600 A(110 V) 2 Poles in Series, 40 °C 600 A(220 V) 3 Poles in Series, 40 °C 600 A(600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 600 A(110 V) 2 Poles in Series, 40 °C 600 A(220 V) 3 Poles in Series, 40 °C 600 A(600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 600 A(110 V) 2 Poles in Series, 40 °C 600 A(220 V) 3 Poles in Series, 40 °C 600 A(600 V) 3 Poles in Series, 40 °C 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Mechanical Durability
3 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 955 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 955 V·APull-in at Max. Rated Control Circuit Voltage DC 895 V·A
Operate Time
Between Coil De-energization and NC Contact Closing 45 ... 55 msBetween Coil De-energization and NO Contact Opening 48 ... 58 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 47 mm²Rigid Al-Cable 2x240 mm²Rigid Cu-Cable 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type
Main Circuit: Bars

Eco Transparency

Environmental Product Declaration - EPD
1SFC100105D0201

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3709332
E-Number (Norway)
4115288
E-Number (Sweden)
3228336

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Circular Value

ABB EcoSolutions
Yes
Circular Design Principles Recyclability Rate
Design for Closing Resource Loops - Standard EN45555 - 63.1 %
End of Life Instructions
1SFC100112M0001
Group Waste to Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Improved Resource Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Sustainable Material Content
Recycled Metal - 37 %

Technical UL/CSA

Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(600 V AC) 550 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 125 hp(208 V AC) Three Phase 125 hp(220 ... 240 V AC) Three Phase 150 hp(440 ... 480 V AC) Three Phase 350 hp(550 ... 600 V AC) Three Phase 400 hp

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900

Related products

2CDS281001R0505 ABB, Power Supply
2CDS281001R0505
ABB
S201P-B50 Miniature Circuit Breaker - 1P - B - 50 A
2CDS282001R0404 ABB, Power Supply
2CDS282001R0404
ABB
S202P-C40 Miniature Circuit Breaker - 2P - C - 40 A
1SNK166172R0000 ABB, Other
1SNK166172R0000
ABB
MC812PA Terminal Block Markers pre-printed : Q (x100) Vertical
1SNK506416R0000 ABB, Other
1SNK506416R0000
ABB
ZS4-SF-R4 Screw Clamp Terminal Block - for Fuses 5x20 mm - Grey - with blown fuse indicator by red LED 115-250V and 2 test sockets screw DIA 2 mm 0.079 in
1SNK706150R0000 ABB, Other
1SNK706150R0000
ABB
ZK4-PE PI-Spring clamp Terminal Block - Ground - Green Yellow
1SNK506153R0000 ABB, Other
1SNK506153R0000
ABB
ZS4-PE-R2 Screw Clamp Terminal Block - Ground - Green/Yellow
ER1050K ABB, Control Cabinets
ER1050K
ABB
IS2-ER1050K Control and Automation Board
EE2051 ABB, Control Cabinets
EE2051
ABB
IS2-EE2051 Control and Automation Board
BP0632 ABB, Accessories
BP0632
ABB
IS2-BP0632 Main Distribution Board