Need more information?
Call us at:+48 17 778 34 19
ABB AF96-30-00-41AF96-30-00-41 24-60V50/60HZ Contactor
1 / 1
Offer Description
AF96-30-00-41 CONT 3P 96A 24-60V50/60HZ
Product Description
The AF96-30-00-41 is a 3 pole - 1000 V IEC or 600 UL contactor with screw terminals, controlling motors up to 45 kW / 400 V AC (AC-3) or 60 hp / 480 V UL and switching power circuits up to 130 A (AC-1) or 115 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Product Details
- Brand
- ABB
- Part Number
- AF96-30-00-41
- EAN
- 39121529
- UPC
- 3471523133204
- UNSPSC
- 39121529
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Power contactor, AC switching
- Class Code : EC000066
- Version : 7
Payment methods:
Offer details
- Best offer from:
Trusted Automa.Net Supplier
- Availability:
- 0 pcs.On RequestUpdated at: 08-10-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing
Are you a Supplier?
Join 650 suppliers, sell to 3500+ verified buyers.
Policies and Information
Return & Refund Policies
14 days for return
Secure Payment Process
Warranty Policies
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price
Dimensions
- Product Net Width
- 70 mm
- Product Net Depth / Length
- 116 mm
- Product Net Height
- 125.5 mm
- Product Net Weight
- 1.22 kg
Technical
- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 0
- Number of Auxiliary Contacts NC
- 0
- Standards
- IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
- Rated Operational Voltage
- Main Circuit 1000 V
- Rated Frequency (f)
- Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
- Rated Operational Current AC-1 (Ie)
- (690 V) 40 °C 130 A(690 V) 60 °C 105 A(690 V) 70 °C 90 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 60 °C 96 A(440 V) 60 °C 96 A(500 V) 60 °C 80 A(690 V) 60 °C 57 A(1000 V) 60 °C 30 A(380 / 400 V) 60 °C 105 A(220 / 230 / 240 V) 60 °C 105 A
- Rated Operational Current AC-3e (Ie)
- (415 V) 60 °C 96 A(440 V) 60 °C 96 A(500 V) 60 °C 80 A(690 V) 60 °C 57 A(380 / 400 V) 60 °C 105 A(220 / 230 / 240 V) 60 °C 105 A
- Rated Operational Power AC-3 (Pe)
- (415 V) 55 kW(440 V) 55 kW(500 V) 55 kW(690 V) 55 kW(1000 V) 40 kW(380 / 400 V) 45 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 25 kW(220 / 230 / 240 V) 30 kW
- Rated Operational Power AC-3e (Pe)
- (415 V) 55 kW(440 V) 55 kW(500 V) 55 kW(690 V) 55 kW(380 / 400 V) 45 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 25 kW(220 / 230 / 240 V) 30 kW
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
- Maximum Electrical Switching Frequency
- (AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour
- Rated Operational Current DC-1 (Ie)
- (110 V) 2 Poles in Series, 40 °C 130 A(110 V) 2 Poles in Series, 60 °C 105 A(110 V) 2 Poles in Series, 70 °C 90 A(110 V) 3 Poles in Series, 40 °C 130 A(110 V) 3 Poles in Series, 60 °C 105 A(110 V) 3 Poles in Series, 70 °C 90 A(220 V) 3 Poles in Series, 40 °C 125 A(220 V) 3 Poles in Series, 60 °C 105 A(220 V) 3 Poles in Series, 70 °C 90 A(72 V) 1-Pole, 40 °C 130 A(72 V) 1-Pole, 60 °C 105 A(72 V) 1-Pole, 70 °C 90 A(72 V) 2 Poles in Series, 40 °C 130 A(72 V) 2 Poles in Series, 60 °C 105 A(72 V) 2 Poles in Series, 70 °C 90 A(72 V) 3 Poles in Series, 40 °C 130 A(72 V) 3 Poles in Series, 60 °C 105 A(72 V) 3 Poles in Series, 70 °C 90 A
- Rated Operational Current DC-3 (Ie)
- (110 V) 2 Poles in Series, 40 °C 130 A(110 V) 2 Poles in Series, 60 °C 105 A(110 V) 2 Poles in Series, 70 °C 90 A(110 V) 3 Poles in Series, 40 °C 130 A(110 V) 3 Poles in Series, 60 °C 105 A(110 V) 3 Poles in Series, 70 °C 90 A(220 V) 3 Poles in Series, 40 °C 130 A(220 V) 3 Poles in Series, 60 °C 105 A(220 V) 3 Poles in Series, 70 °C 90 A(72 V) 1-Pole, 40 °C 130 A(72 V) 1-Pole, 60 °C 105 A(72 V) 1-Pole, 70 °C 90 A(72 V) 2 Poles in Series, 40 °C 130 A(72 V) 2 Poles in Series, 60 °C 105 A(72 V) 2 Poles in Series, 70 °C 90 A(72 V) 3 Poles in Series, 40 °C 130 A(72 V) 3 Poles in Series, 60 °C 105 A(72 V) 3 Poles in Series, 70 °C 90 A
- Rated Operational Current DC-5 (Ie)
- (110 V) 2 Poles in Series, 40 °C 130 A(110 V) 2 Poles in Series, 60 °C 105 A(110 V) 2 Poles in Series, 70 °C 90 A(110 V) 3 Poles in Series, 40 °C 130 A(110 V) 3 Poles in Series, 60 °C 105 A(110 V) 3 Poles in Series, 70 °C 90 A(220 V) 3 Poles in Series, 40 °C 130 A(220 V) 3 Poles in Series, 60 °C 105 A(220 V) 3 Poles in Series, 70 °C 90 A(72 V) 1-Pole, 40 °C 130 A(72 V) 1-Pole, 60 °C 105 A(72 V) 1-Pole, 70 °C 90 A(72 V) 2 Poles in Series, 40 °C 130 A(72 V) 2 Poles in Series, 60 °C 105 A(72 V) 2 Poles in Series, 70 °C 90 A(72 V) 3 Poles in Series, 40 °C 130 A(72 V) 3 Poles in Series, 60 °C 105 A(72 V) 3 Poles in Series, 70 °C 90 A
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 1000 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- 8 kV
- Maximum Mechanical Switching Frequency
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc)
- 50 Hz 24 ... 60 V60 Hz 24 ... 60 VDC Operation -
- Operate Time
- Between Coil De-energization and NC Contact Closing 19 ... 105 msBetween Coil De-energization and NO Contact Opening 17 ... 100 msBetween Coil Energization and NC Contact Opening 38 ... 95 msBetween Coil Energization and NO Contact Closing 42 ... 100 ms
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
- Mounting by Screws (not supplied)
- 2 x M4 or 2 x M6 screws placed diagonally
- Connecting Capacity Main Circuit
- Flexible with Ferrule 1/2x 6 ... 50 mm²Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²Rigid Stranded 1x 6 ... 70 mm²Rigid Stranded 2x 6 ... 50 mm²
- Connecting Capacity Control Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
- Wire Stripping Length
- Control Circuit 10 mmMain Circuit 17 mm
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
- Terminal Type
- Screw Terminals
Classifications
- Object Classification Code
- Q
- ETIM 4
- EC000066 - Magnet contactor, AC-switching
- ETIM 5
- EC000066 - Magnet contactor, AC-switching
- EClass
- V11.0 : 27371003
- IDEA Granular Category Code (IGCC)
- 4758 >> Iec Contactors
- E-Number (Finland)
- 3707134
Environmental
- Ambient Air Temperature
- Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
- Climatic Withstand
- Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6
- 5 ... 300 Hz 3 g closed position / 3 g open position
- Resistance to Shock acc. to IEC 60068-2-27
- Closed, Shock Direction: A 25 gClosed, Shock Direction: B1 25 gClosed, Shock Direction: B2 15 gClosed, Shock Direction: C1 25 gClosed, Shock Direction: C2 25 gOpen, Shock Direction: B1 5 g
- RoHS Status
- Following EU Directive 2011/65/EU
Technical UL/CSA
- General Use Rating UL/CSA
- (600 V AC) 115 A
- Horsepower Rating UL/CSA
- (120 V AC) Single Phase 7-1/2 hp(200 ... 208 V AC) Three Phase 30 hp(220 ... 240 V AC) Three Phase 40 hp(240 V AC) Single Phase 20 hp(440 ... 480 V AC) Three Phase 75 hp(550 ... 600 V AC) Three Phase 75 hp
- Connecting Capacity Main Circuit UL/CSA
- Rigid Stranded 1/2x 6-1 AWG
- Connecting Capacity Control Circuit UL/CSA
- Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
- Tightening Torque UL/CSA
- Control Circuit 11 in·lbMain Circuit 53 in·lb
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900
Documents
Data Sheet
Datasheet for ABB AF96-30-00-41, including specifications and features.
Download Data SheetOther Categories
Actuators
Blocks
Cables, Pipes & Hoses
Compressors
Control
Couplings & Fittings
Cylinders & Pistons
Electronics
Filters
HVAC
Industrial PC's & HMIs
Lighting
Linear technique
Motors
Power Supply
Power Transmission
Pumps & Valves
Renewable energy
Robotics
Seals, Rings & Connectors
Sensors & Measuring Devices
Tools and Accessories
CNC
Other
Drives & Inverters