Eaton
207247
1 / 2
- Part Number
- 207247
- EAN
- 4015082072476
€258.30
net€271.90
Free Shipping!1
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 7 pcs.In-StockUpdated at: 14-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- 22-27 November to United Kingdom
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Specifications
- Rated operational current for specified heat dissipation (In)
- 63 A
- 10.11 Short-circuit rating
- Is the panel builder's responsibility. The specifications for the switchgear must be observed.
- Rated operational current (Ie) at DC-23A, 24 V
- 50 A
- Rated operational power at AC-3, 380/400 V, 50 Hz
- 22 kW
- 10.4 Clearances and creepage distances
- Meets the product standard's requirements.
- Mounting method
- Surface mounting
- Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)
- 520 A
- 10.2.3.1 Verification of thermal stability of enclosures
- Meets the product standard's requirements.
- Fitted with:
- Black rotary handle and locking ring
- Degree of protection (front side)
- IP65
- Short-circuit current rating (high fault)
- 100 A, Class J, max. Fuse, SCCR (UL/CSA)
- Rated operational current (Ie) at DC-23A, 120 V
- 25 A
- Rated operational current (Ie) at DC-23A, 240 V
- 20 A
- Rated conditional short-circuit current (Iq)
- 2 kA
- Actuator type
- Door coupling rotary drive
- Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)
- 800 A
- Ambient operating temperature - max
- 40 °C
- Assigned motor power at 115/120 V, 60 Hz, 1-phase
- 3 HP
- Features
- Version as maintenance-/service switch
- Electrical connection type of main circuit
- Screw connection
- Rated breaking capacity at 500 V (cos phi to IEC 60947-3)
- 480 A
- Number of poles
- Six-pole
- Rated operational power star-delta at 380/400 V, 50 Hz
- 30 kW
- Ambient operating temperature - min
- -25 °C
- 10.6 Incorporation of switching devices and components
- Does not apply, since the entire switchgear needs to be evaluated.
- Rated uninterrupted current (Iu)
- 63 A
- 10.2.6 Mechanical impact
- Does not apply, since the entire switchgear needs to be evaluated.
- 10.3 Degree of protection of assemblies
- Does not apply, since the entire switchgear needs to be evaluated.
- Operating frequency
- 1200 Operations/h
- Product Category
- Main switch
- Number of contacts in series at DC-23A, 48 V
- 2
- Rated operational current (Ie) at DC-23A, 48 V
- 50 A
- Terminal capacity
- 1 x (1 - 25) mm², flexible with ferrules to DIN 46228
- Number of contacts in series at DC-23A, 24 V
- 1
- Heat dissipation capacity Pdiss
- 0 W
- Assigned motor power at 460/480 V, 60 Hz, 3-phase
- 40 HP
- Assigned motor power at 200/208 V, 60 Hz, 1-phase
- 7.5 HP
- Rated operational current (Ie) at AC-23A, 400 V, 415 V
- 63 A
- Switching angle
- 90 °
- 10.9.2 Power-frequency electric strength
- Is the panel builder's responsibility.
- Overvoltage category
- III
- Degree of protection
- NEMA 12
- Actuator color
- Black
- Rated operational current (Ie) at AC-23A, 230 V
- 63 A
- Rated operational current (Ie) at DC-13, control switches L/R = 50 ms
- 25 A
- Pollution degree
- 3
- Rated operational power at AC-23A, 500 V, 50 Hz
- 22 kW
- Rated impulse withstand voltage (Uimp)
- 6000 V AC
- Switching power at 400 V
- 30 kW
- Voltage per contact pair in series
- 60 V
- Functions
- Interlockable
- Tightening torque
- 35.4 lb-in, Screw terminals
- Rated operational power at AC-3, 690 V, 50 Hz
- 15 kW
- Rated operational current (Ie) at AC-3, 660 V, 690 V
- 17 A
- 10.2.2 Corrosion resistance
- Meets the product standard's requirements.
- 10.2.4 Resistance to ultra-violet (UV) radiation
- UV resistance only in connection with protective shield.
- 10.2.7 Inscriptions
- Meets the product standard's requirements.
- Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
- 41 A
- Rated operational current (Ie) star-delta at AC-3, 380/400 V
- 63 A
- Number of auxiliary contacts (normally open contacts)
- 1
- Shock resistance
- 15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
- Assigned motor power at 230/240 V, 60 Hz, 3-phase
- 15 HP
- Ambient operating temperature (enclosed) - min
- -25 °C
- Number of contact units
- 4
- Rated operational power at AC-23A, 400 V, 50 Hz
- 30 kW
- Rated operational current (Ie) at AC-23A, 500 V
- 33 A
- Rated operational current (Ie) at DC-23A, 60 V
- 50 A
- Rated operational power at AC-23A, 220/230 V, 50 Hz
- 18.5 kW
- 10.12 Electromagnetic compatibility
- Is the panel builder's responsibility. The specifications for the switchgear must be observed.
- 10.2.5 Lifting
- Does not apply, since the entire switchgear needs to be evaluated.
- Locking facility
- Lockable in the 0 (Off) position
- Ambient operating temperature (enclosed) - max
- 40 °C
- Rated operational current (Ie) at AC-21, 440 V
- 63 A
- Rated operational voltage (Ue) at AC - min
- 690 V
- 10.8 Connections for external conductors
- Is the panel builder's responsibility.
- Screw size
- M6, Terminal screw
- Assigned motor power at 575/600 V, 60 Hz, 3-phase
- 40 HP
- Load rating
- 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor)
- Rated operational current (Ie) at AC-23A, 690 V
- 23.8 A
- Rated permanent current at AC-21, 400 V
- 63 A
- Rated operational power at AC-3, 415 V, 50 Hz
- 22 kW
- Climatic proofing
- Damp heat, cyclic, to IEC 60068-2-30
- Device construction
- Complete device in housing
- Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)
- 600 A
- Static heat dissipation, non-current-dependent Pvs
- 0 W
- 10.9.3 Impulse withstand voltage
- Is the panel builder's responsibility.
- 10.5 Protection against electric shock
- Does not apply, since the entire switchgear needs to be evaluated.
- Safe isolation
- 440 V AC, Between the contacts, According to EN 61140
- Mounting position
- As required
- Safety parameter (EN ISO 13849-1)
- B10d values as per EN ISO 13849-1, table C.1
- 10.13 Mechanical function
- The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
- Rated operational power at AC-23A, 690 V, 50 Hz
- 22 kW
- Rated operational power star-delta at 220/230 V, 50 Hz
- 18.5 kW
- 10.9.4 Testing of enclosures made of insulating material
- Is the panel builder's responsibility.
- Heat dissipation per pole, current-dependent Pvid
- 4.5 W
- Rated operational power star-delta at 500 V, 50 Hz
- 37 kW
- Uninterrupted current
- Rated uninterrupted current Iu is specified for max. cross-section.
- Equipment heat dissipation, current-dependent Pvid
- 0 W
- Assigned motor power at 200/208 V, 60 Hz, 3-phase
- 15 HP
- Suitable for
- Ground mounting
- Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)
- 340 A
- Number of contacts in series at DC-23A, 240 V
- 6
- Number of auxiliary contacts (normally closed contacts)
- 1
- Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms
- 63 A
- Rated operational current (Ie) star-delta at AC-3, 690 V
- 29.4 A
- 10.2.3.2 Verification of resistance of insulating materials to normal heat
- Meets the product standard's requirements.
- Rated operational power star-delta at 690 V, 50 Hz
- 22 kW
- 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
- Meets the product standard's requirements.
- Lifespan, mechanical
- 500,000 Operations
- Number of contacts in series at DC-23A, 60 V
- 3
- Control circuit reliability
- 1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
- Rated short-time withstand current (Icw)
- 1,3 kA, Contacts, 1 second
- Number of auxiliary contacts (change-over contacts)
- 0
- Rated operational voltage (Ue) at AC - max
- 690 V
- 10.7 Internal electrical circuits and connections
- Is the panel builder's responsibility.
- 10.10 Temperature rise
- The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
- Switching capacity (main contacts, general use)
- 63 A, Rated uninterrupted current max. (UL/CSA)
- Number of contacts in series at DC-23A, 120 V
- 3
- Rated operational current (Ie) at AC-3, 500 V
- 33 A
- Assigned motor power at 230/240 V, 60 Hz, 1-phase
- 10 HP
- Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
- 51 A
- Rated operational current (Ie) star-delta at AC-3, 220/230 V
- 63 A
- Short-circuit protection rating
- 80 A gG/gL, Fuse, Contacts
- Rated operational current (Ie) star-delta at AC-3, 500 V
- 57.2 A
General
- Model Code
- T5B-4-15682/I4/SVB-SW
- EAN
- 4015082072476
- Product Length/Depth
- 240 mm
- Product Height
- 204 mm
- Product Width
- 160 mm
- Product Weight
- 1.49 kg
- Warranty
- Not Applicable
- Certifications
- UL Listed
- Catalog Notes
- Rated Short-time Withstand Current (Icw) for a time of 1 second
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther