Littelfuse

KRD9120B

1 / 1
thumbnail

Description

Operation (Retriggerable Single Shot) Function Type A (Output Initially De-energized): Input voltage must be applied prior to and during timing. When the initiate switch is closed, (momentary or maintained) the output energizes and the time delay starts. On completion of the delay, the output de-energizes. The unit will time out if S1 remains in the open or closed position for the full time delay. Re-closing the initiate switch resets the time delay and restarts timing; the output remains energized. The output will not energize if the initiate switch is closed when input voltage is applied. Function Type B (Output Initially Energized): Upon application of input voltage, the output energizes and the time delay starts. At the end of the time delay, the load de-energizes. The unit will time out if S1 remains in the open or closed position for the full time delay. Closing (re-closing) the initiate switch resets the time delay and restarts timing; the output remains energized. Reset: The time delay and the output are reset when input voltage is removed.
Part Number
KRD9120B
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Input Voltage (V)
12VDC
Input Tolerance (%)
-15% - 20%
Input DC Ripple (%)
≤10%
Output Type
Isolated relay contacts
Output Form
SPDT
Output Load Rating (VA)
10A resistive @ 125VAC; 5A resistive @ 230VAC and 28VDC; 1/4hp @ 125VAC
Maximum Output Voltage (V)
250VAC
Time Delay Type
Microcontroller based with watchdog circuitry
Time Delay Range
0.1 - 10s onboard adjustable
Time Delay Tolerance (%)
≤±5%
Reset Time (ms)
≤150ms
Initiate Time (ms)
≤40ms; ≤750 operations per minute
Repeat Accuracy (%)
±0.5% or 20ms whichever is greater
Setpoint vs Ambient Temperature and Operating Voltage (%)
≤ ±5%
Insulation Resistance
≥100 MΩ
Isolation Voltage (V)
≥1500V RMS input to output
Circuitry
Encapsulated
Polarity
DC units are reverse polarity protected
Life
Mechanical - 1 x 107; Electrical - 1 x 105
Power Consumption
≤2W
Termination Type
0.25 in. (6.35mm) male quick connect terminals
Mounting Method
Surface mount with one #10 (M5 x 0.8) screw
Operating Temperature
-40° to 60°C (-40°F to 140°F)
Storage Temperature (F/C)
-40° to 85°C (-40°F to 185°F)
Humidity
95% relative non-condensing
Dimensions
2.00 x 2.00 x 1.21 in. (50.8 x 50.8 x 30.7mm)
Weight (lbs/g)
≅2.6oz (74g)
Sample capable
No

Documents

Data Sheet

Download