Bayed climate control designed for siting within a bayed enclosure suite. The hot air is extracted at the rear of the unit, cooled and then expelled forwards to the cold aisle.
Part Number
3313568
Tariff Code
84195080
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Air throughput (unimpeded air flow)
Air throughput at 60 Hz:8,000 m/h
Benefits
Maximum energy efficiency due to EC fan technology and IT-based control, Minimal pressure loss at the air end, which in turn minimizes the power consumption of the fans, Optimum adaptability due to dynamic, continuous control of the cold water volume flow, By using high water inlet temperatures, the proportion of indirect free cooling is increased, which in turn reduces operating costs, Targeted cooling output thanks to modular fan units, Fan modules configurable as n+1 redundancy., Redundant temperature sensor integrated at the air end, The separation of cooling and enclosure prevents water from entering the server enclosure, A maximum floor area of 0.36 m for all cooling services, Optimum access for maintenance and service from the front and the rear, Tool-free fan module replacement
Color
RAL 9005
Width
300 mm
Height
2000 mm
Depth
1200 mm
Duty cycle
1
EC fan
1
Fans may be exchanged with the system operational
1
Function principle
The hot air is drawn in from the room or hot aisle at the rear of the device and expelled at the front into the cold aisle after cooling. With this product, a raised floor is not necessary
Installation in bayed enclosure suite
Protruded
Material
Carbon steel, spray finished
Max. cooling output
53 kW
Monitoring
Monitoring of all system-relevant parameters such as server air intake temperature, server waste air temperature, water inlet/return temperature, water flow, cooling output, fan speed, leakage., Direct connection of the unit via SNMP over Ethernet, Integration into RiZone
Options
Direct connection of additional CMC III sensors is also possibleRacks 2200 mm high
Packaging unit
1 pc(s).
Permissible operating pressure (p. max.)
10bar
Protection category IP to EN 60 529
IP 20
Protection category IP to IEC 60 529
IP 20
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz, 200 - 240 V AC
Suitable for enclosure type
VX IT, TS IT PRO
Surface finish
RAL 9005, fine structure matt
Temperature control
Infinitely variable fan control, 2-way control ball valve
Total cooling output/number of fan modules
48 kW/451 kW/553 kW/6
Type of connection (electrical)
Connector
Version
Row Cooling
Water connections
DN 40 (G 1" external thread)
Water inlet temperature
15 C
Weight/packaging unit
260 kg