This Altistart 01 soft starter is DIN rail mounted and can feed single or 3-phase asynchronous motors with a rating up to 25A. This Altistart 01 can be used for a motor rated power up to 11kW or 15hp for 3-phase (110V to 480V AC) and up to 2.2kW for single phase (110V to 230V AC). This DIN rail mounted soft starter is designed to enable smooth start for simple machines such as conveyors, conveyor belts, pumps, fans, compressors, automatic doors and gates, small cranes and belt-driven machinery. It is 45mm wide, this makes it one of the smallest soft starters on the market; it can be installed nearly everywhere. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Simple setup with only 2 settings: possible to configure by non-specialists. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
Country of Origin
DE
Part Number
ATS01N125FT
Tariff Code
85371098
EAN
3389119200455
UNSPSC
39121521
Payment methods:
Best offer from:
ITTrusted Automa.Net Supplier
Availability:
9 pcs.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 23 Parts In-Stock from 3 Distributors
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (2)

Best offer
ATS01N125FT product image
Schneider Electric

ATS01N125FT

Condition:
New Factory Sealed
Available:
10 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
ATS01N125FT product image
Schneider Electric

ATS01N125FT

Condition:
New Surplus
Available:
4 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
USTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1

Environment

Product Certifications
B44.1-96/ASME A17.5 for starter wired to the motor delta terminal || C-tick || CCC || GOST || CSA || UL
Standards
EN/IEC 60947-4-2
Electromagnetic Compatibility
conducted and radiated emissions level B CISPR 11 || conducted and radiated emissions level B IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || EMC immunity level 3 EN 50082-1 || EMC immunity level B EN 50082-2 || harmonics level 3 IEC 1000-3-2 || harmonics level 3 IEC 1000-3-4 || immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 || micro-cuts and voltage fluctuation IEC 61000-4-11 || voltage/current impulse level 3 IEC 61000-4-5
Ambient Air Temperature For Operation
-10-40 °C without derating) || 40-50 °C with current derating of 2 % per °C)
Shock Resistance
15 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
1 gn 13-150 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz)EN/IEC 60068-2-6
Pollution Degree
2 EN/IEC 60947-4-2
Ambient Air Temperature For Storage
-25-70 °C EN/IEC 60947-4-2
Relative Humidity
5-95 % without condensation or dripping water EN/IEC 60068-2-3
Ip Degree Of Protection
IP20
Operating Altitude
<= 3280.84 ft (1000 m) without derating || > 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Electrical Connection
4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit || screw connector - rigid without cable end 1 0.5...2.5 mm² AWG 14 control circuit || 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit || screw connector - rigid 2 0.5...1 mm² AWG 17 control circuit || screw connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit || 4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuit || screw connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit || 4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit || 4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuit || screw connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit
Network Frequency
47.5...63 Hz
[Uc] Control Circuit Voltage
110 V AC +/- 10 % 35 mA || 24 V AC/DC +/- 10 % 30 mA || 240 V AC +/- 10 % 80 mA
Height
124 mm
Marking
CE
Power Range
2.2-3 kW 200-240 V 3 phase || 2.2-3 kW 200-240 V 1 phase || 4-6 kW 200-240 V 3 phase || 7-11 kW 200-240 V 3 phase || 7-11 kW 380-440 V 3 phase
Net Weight
0.35 kg
Discrete Output Current
2 A DC-13 || 3 A AC-15
Motor Starter Type
soft starter
Function Available
integrated bypass
Supply Voltage Limits
99-528 V
Starting Time
1 s / 100 || 5 s / 20 || adjustable from 1 to 5 s
Assembly Style
with heat sink
Compatibility Code
ATS01N1
Output Voltage
<= power supply voltage
Operating Position
vertical +/- 10 degree
Width
45 mm
Depth
131 mm
Starting Torque
30...80 % of starting torque of motor connected directly on the line supply
Tightening Torque
0.5-0.5 N.m || 1.9-2.5 N.m
Supply Frequency
50...60 Hz - 5...5 %

Specifications

Current Consumption
125 A at nominal load
Product Destination
asynchronous motors
Range Of Product
Altistart 01
Product Or Component Type
soft starter
Motor Power Kw
11 kW, 3 phase 400 V || 3 kW, 3 phase 230 V || 4 kW, 3 phase 230 V || 9 kW, 3 phase 400 V || 7.5 kW, 3 phase 400 V || 5.5 kW, 3 phase 230 V || 2.2 kW, 1 phase 230 V
Phase
1 phase
Power Dissipation In W
1 W at full load and at end of starting || 126 W in transient state
Utilisation Category
AC-53B EN/IEC 60947-4-2
Icl Starter Rating
25 A
Type Of Start
start with voltage ramp
[Us] Rated Supply Voltage
110...480 V - 10...10 %
Product Specific Application
simple machine
Maximum Horse Power Rating
11 hp, 3 phase 460 V || 2 hp, 3 phase 210 V || 3 hp, 3 phase 210 V || 5 hp, 3 phase 230 V || 9 hp, 3 phase 460 V || 7.5 hp, 3 phase 230 V
Device Short Name