Schneider Electric

ATV212HD11N4

1 / 3
thumbnail
thumbnail
thumbnail

Description

Active Mature
This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 11kW / 15hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 6.45kg and its dimensions are, 180mm wide, 232mm high, 170mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
Country of Origin
ID
Part Number
ATV212HD11N4
Tariff Code
85044095
EAN
3606480322518
UNSPSC
39122001
Payment methods:
Best offer from:
GBTrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 20 Parts In-Stock from 4 Distributors
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (3)

ATV212HD11N4 product image
Schneider Electric

ATV212HD11N4

Condition:
New Factory Sealed
Available:
11 pcs.
In-Stock
Updated at: 22-11-2024
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
ATV212HD11N4 product image
Schneider Electric

ATV212HD11N4

Condition:
New Surplus
Available:
4 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
£945.53
net
ATV212HD11N4 product image
Schneider Electric

ATV212HD11N4

Condition:
New Surplus
Available:
4 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
USTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1

Environment

Product Certifications
C-tick || NOM 117 || CSA || UL
Standards
IEC 61800-3 category C2 || IEC 61800-3 environments 1 category C2 || IEC 61800-3 category C3 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 environments 2 category C3 || UL Type 1 || IEC 61800-3 environments 1 category C1 || IEC 61800-3 environments 2 category C2 || IEC 61800-3 || IEC 61800-5-1 || EN 55011 class A group 1 || EN 61800-3 category C3 || IEC 61800-3 environments 2 category C1
Electromagnetic Compatibility
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test IEC 61000-4-11
Ambient Air Temperature For Operation
-10-40 °C without derating) || 40-50 °C with derating factor)
Shock Resistance
15 gn 11 ms IEC 60068-2-27
Environmental Characteristic
classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
Marking
CE
Vibration Resistance
1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
Noise Level
51 dB 86/188/EEC
Pollution Degree
2 IEC 61800-5-1
Regulation Loop
adjustable PI regulator
Ambient Air Temperature For Storage
-25-70 °C
Relative Humidity
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Assembly Style
with heat sink
Ip Degree Of Protection
IP20 on upper part without blanking plate on cover IEC 61800-5-1 || IP20 on upper part without blanking plate on cover IEC 60529 || IP21 IEC 61800-5-1 || IP21 IEC 60529 || IP41 on upper part IEC 61800-5-1 || IP41 on upper part IEC 60529
Operating Altitude
3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Operating Position
vertical +/- 10 degree

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Prospective Line Isc
22 kA
Electrical Connection
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 16-16 mm² / AWG 6
Network Frequency
47.5...63 Hz
Discrete Input Logic
positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Type Of Cable
without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Height
232 mm
Acceleration And Deceleration Ramps
automatic based on the load || linear adjustable separately from 0.01 to 3200 s
Analogue Output Type
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Speed Drive Output Frequency
0.5-200 Hz
Discrete Output Type
configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Transmission Frame
RTU
Torque Accuracy
+/- 15 %
Asynchronous Motor Control Profile
voltage/frequency ratio, 2 points || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || flux vector control without sensor, standard || voltage/frequency ratio - Energy Saving, quadratic U/f || voltage/frequency ratio, 5 points
Maximum Switching Current
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Communication Service
read holding registers (03) 2 words maximum || time out setting from 0.1 to 100 s || write single register (06) || monitoring inhibitable || write multiple registers (16) 2 words maximum || read device identification (43)
Transient Overtorque
120-120 % of nominal motor torque +/- 10 % 60 s
Insulation Resistance
>= 1 mOhm 500 V DC for 1 minute
Response Time
FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Data Format
8 bits, 1 stop, odd even or no configurable parity
Apparent Power
17.1 kVA 380 V
Dielectric Strength
3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
Power Range
7-11 kW 380-440 V 3 phase || 7-11 kW 480-500 V 3 phase
Net Weight
6.45 kg
Type Of Polarization
no impedance
Frequency Resolution
display unit 0.1 Hz || analog input 0.024/50 Hz
Accuracy
+/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Switching Frequency
6...16 kHz adjustable || 12...16 kHz with derating factor
Maximum Transient Current
24.8 A 60 s
Connector Type
1 open style || 1 RJ45
Analogue Input Number
2
Functionality
mid
Motor Slip Compensation
not available in voltage/frequency ratio motor control || adjustable || automatic whatever the load
Motor Starter Type
variable speed drive
Discrete Output Number
2
Minimum Switching Current
3 mA 24 V DC configurable relay logic
Analogue Output Number
1
Physical Interface
2-wire RS 485
Power Dissipation In W
430 W
Continuous Output Current
22.5 A 380 V || 22.5 A 460 V
Number Of Addresses
1-247
Tightening Torque
0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 2.5 N.m, 22 lb.in L1/R, L2/S, L3/T)
Discrete Input Type
F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Speed Range
1-10
Isolation
electrical between power and control
Local Signalling
for DC bus energized 1 LED (red)
Linearity Error
VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Specific Application
HVAC
Output Voltage
<= power supply voltage
Nominal Switching Frequency
12 kHz
Width
180 mm
Transmission Rate
9600 bps or 19200 bps
Braking To Standstill
by DC injection
Air Flow
147 m3/h
Depth
170 mm
Protection Type
overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit drive || against exceeding limit speed drive || line supply overvoltage and undervoltage drive || line supply undervoltage drive || against input phase loss drive || thermal protection motor || motor phase break motor || with PTC probes motor
Supply
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Analogue Input Type
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Discrete And Process Manufacturing
building - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump
Sampling Duration
2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Speed Accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
Option Card
communication card LonWorks

Specifications

Product Destination
asynchronous motors
Range Of Product
Altivar 212
Product Or Component Type
variable speed drive
Ip Degree Of Protection
IP21
Motor Power Kw
11 kW
Phase
3 phase
Line Current
16.8 A 480 V || 21.1 A 380 V
[Us] Rated Supply Voltage
380...480 V - 15...10 %
Communication Port Protocol
METASYS N2 || APOGEE FLN || LonWorks || BACnet || Modbus
Supply Voltage Limits
323-528 V
Product Specific Application
pumps and fans in HVAC
Emc Filter
Class C2 EMC filter integrated
Maximum Horse Power Rating
15 hp
Device Short Name
ATV212
Supply Frequency
50...60 Hz - 5...5 %

CAD Models

traceparts
traceparts
Download