Schneider Electric LC1D258U7

IEC Contact, TeSys Deca Nonreversing 40A Resistive, 4 Pole, 2 NO and 2 NC, 240VAC Coil, Open Style

1 / 1
Schneider Electric LC1D258U7 IEC Contact, TeSys Deca Nonreversing 40A Resistive, 4 Pole, 2 NO and 2 NC, 240VAC Coil, Open Style — Electronics & PCBs
Manufacturer catalogue image

Product Description

Lifecycle Status:

TeSys D contactors are engineered for seamless integration into control systems. They are versatile, suitable for creating motor starters across a wide range of applications. TeSys D contactors come in 13 contactor ratings, catering to inductive motor loads up to 150 full-load amps and resistive loads up to 200 amps.

This particular IEC contactor is a 4 pole unit with two normally open (NO) and two normally closed (NC) power contacts. It boasts a 40A resistive load rating, making it ideal for resistive loads. The contactor comes equipped with a 240VAC 50/60 Hz coil, ensuring reliable operation.

The contactor also features an integrated auxiliary contact, both NO and NC types. The NC contact is mirror certified for added reliability. Terminals are screw clamp type, facilitating easy connection of load and auxiliary components.

With its compact dimensions of 4.13 inches in height, 1.77 inches in width, and 3.90 inches in depth, this contactor is suitable for DIN rail or panel mounting. It weighs 0.94 lbs, making it a lightweight yet robust solution.

Certified to UL, CSA, IEC, CCC, EAC, and Marine standards, this contactor meets the highest safety and performance benchmarks. Its compliance with RoHS/REACh regulations further solidifies its status as a Green Premium product.

Send Inquiry
Payment methods:

Offer details

Best offer from:
Trusted supplier — United Kingdom, member since 2021
Availability:
2 pcs.
In-Stock
Updated at: 31-10-2025
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Specifications

Product Certifications
UL || CSA || CCC || EAC || UKCA || CB || EU-RO-MR by DNV-GL
Standards
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Climatic Withstand
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Flame Retardance
V1 conforming to UL 94
Protective Treatment
THIEC 60068-2-30
Ip Degree Of Protection
IP20 front face IEC 60529

Available Offers

(6)
LC1D258U7 Schneider Electric, Electronics & PCBs

Schneider Electric

Available:
1 pc.
In-Stock
Updated at: 05-09-2026
Offer from:
Trusted supplier — United Kingdom, member since 2023
Warranty:
12 months
LC1D258U7 Schneider Electric, Electronics & PCBs

Schneider Electric

Available:
1 pc.
On Request
Updated at: 22-08-2026
Offer from:
Trusted supplier — Romania, member since 2023, 1–4 employees
LC1D258U7 Schneider Electric, Electronics & PCBs

Schneider Electric

Available:
1 pc.
In-Stock
Updated at: 04-09-2026
Offer from:
Trusted supplier — Germany, member since 2024
Warranty:
24 months

Access our platform to find more offers

Register now to explore 36 mln offers from verified suppliers worldwide.Including 2 more offers for this product.

  • Compare offers globally
  • Direct supplier contact
  • RFQs, Quotes, and Orders
  • BOM Search
Sign UpFree 14-day trial available
Offer with manufacturer lead time
Directly from the manufacturer - with a confirmed, predictable, and fully transparent delivery time.
Get Quote

Documents

Data Sheet

Datasheet for Schneider Electric LC1D258U7, including specifications and features.

Download Data Sheet
TracePartsTraceParts

CAD Models

3D CAD model and technical drawings, ready for your design software.

Download CAD Model

Compatible Products

LAD4RCU Schneider Electric
LAD4RCU
Schneider Electric
TeSys D suppressor module, for LC1D09-D38, LC1DT20-DT40 contactors and CAD control relays
LAD4VU Schneider Electric
LAD4VU
Schneider Electric
A TeSys D suppressor module designed for LC1D09-D38 and LC1DT20-DT40 contactors and CAD control relays. It provides varistor protection limiting transient voltage to 2 Uc max.
LAD8N02 Schneider Electric
LAD8N02
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N11 Schneider Electric
LAD8N11
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N20 Schneider Electric
LAD8N20
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD9ET1S Schneider Electric
LAD9ET1S
Schneider Electric
TeSys D safety protective cover, for preventing access to the moving contact carrier
LADN02 Schneider Electric
LADN02
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN04 Schneider Electric
LADN04
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN11 Schneider Electric
LADN11
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN13 Schneider Electric
LADN13
Schneider Electric
Schneider Electric's TeSys Deca auxiliary contact block offers 1NO+3NC instantaneous contacts rated up to 10A 690V AC. It is suitable for safety applications and can be easily mounted on front by clip-on.
LADN20 Schneider Electric
LADN20
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN22 Schneider Electric
LADN22
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN31 Schneider Electric
LADN31
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN40 Schneider Electric
LADN40
Schneider Electric
The TeSys Deca auxiliary contact block provides four normally open (NO) contacts for integration into control circuits with LC1D09 to LC1D150 contactors.
LADR0 Schneider Electric
LADR0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR2 Schneider Electric
LADR2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR4 Schneider Electric
LADR4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADS2 Schneider Electric
LADS2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT0 Schneider Electric
LADT0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT2 Schneider Electric
LADT2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT4 Schneider Electric
LADT4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD

Spare Parts

LXD1U7 Schneider Electric
LXD1U7
Schneider Electric
"TeSys Deca replacement coil 240V AC 50/60Hz, for TeSys Deca contactors

Market insights

AutomaINSIGHTS analytics dashboard

Get real-time analytics and market data to optimize your purchasing decisions for this component and similar products

  • Real-time stock availability data from 700 MRO distributors in Europe and USA
  • Price analysis by condition (new, used, refurbished) with market median prices
  • Critical component availability monitoring to prevent production downtime
  • Inventory optimization insights based on market supply trends
Get Started