1 / 2
thumbnail
thumbnail

Description

Active Mature
TeSys K overload relays are designed to be used with TeSys K contactors to make a motor starter. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 5.5 to 8 amperes. This trip current rating is calibrated per Class 10A. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).
Country of Origin
CZ
Part Number
LR2K0314
Tariff Code
85364900
EAN
3389110230574
UNSPSC
39122330
£26.46
net
1
Payment methods:
Best offer from:
GBTrusted Automa.Net Supplier
Availability:
10 pcs.
In-Stock
Updated at: 21-11-2024
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
A total of 37 Parts In-Stock from 3 Distributors
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (2)

Best offer
LR2K0314 product image
Schneider Electric

LR2K0314

Condition:
New Factory Sealed
Available:
23 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
LR2K0314 product image
Schneider Electric

LR2K0314

Condition:
New Surplus
Available:
4 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
USTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1

Environment

Product Certifications
UL || CSA || UKCA
Mechanical Robustness
shocks NO contact10 Gn for 11 ms IEC 60068-2-27 || shocks NC contact10 Gn for 11 ms IEC 60068-2-27 || vibrations NO contact2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations NC contact2 Gn, 5...300 Hz IEC 60068-2-6
Standards
VDE 0660 || NF C 63-650 || IEC 60947 || BS 4941
Ambient Air Temperature For Operation
-20-55 °C without derating IEC 60947 || -30-60 °C with derating IEC 60947
Ip Degree Of Protection
IP2X conforming to IEC 60529
Flame Retardance
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Ambient Air Temperature For Storage
-40-70 °C
Protective Treatment
TC IEC 60068 || TC DIN 50016
Operating Altitude
6561.68 ft (2000 m) without derating
Fire Resistance
850 °C IEC 60695-2-1

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2211018
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI2211018
Eu Rohs Directive
Compliant with Exemptions

Complementary

Network Frequency
<= 400 Hz
Height
58 mm
[Ith] Conventional Free Air Thermal Current
6 A signalling circuit
Auxiliary Contact Composition
1 NO + 1 NC
Phase Failure Sensitivity
yes IEC 60947-4-1
[Ue] Rated Operational Voltage
<= 690 V power circuit || 690 V AC AC-15 signalling circuit || 250 V DC DC-13 signalling circuit
Associated Fuse Rating
6 A gG for signalling circuit conforming to VDE 0660 || 6 A gG for signalling circuit conforming to IEC 60947
Net Weight
0.145 kg
Connections - Terminals
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
[Uimp] Rated Impulse Withstand Voltage
6 kV
Power Dissipation Per Pole
2 W
Local Signalling
trip indicator Yellow)
Tightening Torque
1.3 N.m screw clamp terminals Philips No 2 || 1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
Control Type
Red push-button trip test function || Blue push-button stop and manual reset || selector switch manual or automatic reset
Mounting Support
under contactor || plate, with specific accessories || rail, with specific accessories
Width
45 mm
Depth
65 mm

Specifications

Network Type
DC || AC
Thermal Protection Adjustment Range
5.5-8 A
Relay Application
motor protection
Product Or Component Type
differential thermal overload relay
Product Name
TeSys LRK
Thermal Overload Class
class 10A IEC 60947-4-1
Range
TeSys
[Ui] Rated Insulation Voltage
power circuit 690 V BS 4941 || power circuit 690 V IEC 60947 || power circuit 750 V VDE 0110 group C || power circuit 600 V CSA C22.2 No 14
Product Compatibility
LC7K || LC1K || LP4K || LP1K
Device Short Name
LR2K

CAD Models

traceparts
traceparts
Download