Schneider Electric LRD32L

TeSys Deca thermal overload relays - 23...32 A - class 20

1 / 1
Schneider Electric LRD32L TeSys Deca thermal overload relays - 23...32 A - class 20 — General Accessories
Manufacturer catalogue image

Product Description

Lifecycle Status:
LRD32L is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 15kW@400V thanks to a thermal range 23-32A, a tripping class 20 and phase unbalance protection. LRD32L is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 23-32A, a tripping class 20 and phase unbalance detection, it protects motors 15kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D25-D38 to form a compact starter. Light and compact, 45mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).
Send Inquiry
Payment methods:

Offer details

Best offer from:
Trusted supplier — Romania, member since 2023, 1–4 employees
Availability:
1 pc.
On Request
Updated at: 22-08-2026
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
The Seller is responsible for shipping the product and invoicing

Specifications

Product Certifications
IEC || UL || CSA || EAC || ABS || ATEX INERIS || UKCA
Mechanical Robustness
shocks15 Gn for 11 ms IEC 60068-2-7 || vibrations3 GN IEC 60068-2-6
Standards
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || EN 50495
Climatic Withstand
IACS E10
Ambient Air Temperature For Operation
-20-60 °C without derating IEC 60947-4-1
Dielectric Strength
1.89 kV 50 Hz IEC 60947-1

Available Offers

(2)
LRD32L Schneider Electric, General Accessories

Schneider Electric

Available:
0 pcs.
On Request
Updated at: 14-09-2026
Offer from:
Trusted supplier — Italy, member since 2021, 10–19 employees
Warranty:
12 months

Access our platform to find more offers

Register now to explore 36 mln offers from verified suppliers worldwide.

  • Compare offers globally
  • Direct supplier contact
  • RFQs, Quotes, and Orders
  • BOM Search
Sign UpFree 14-day trial available
Offer with manufacturer lead time
Directly from the manufacturer - with a confirmed, predictable, and fully transparent delivery time.
Get Quote

Documents

Data Sheet

Datasheet for Schneider Electric LRD32L, including specifications and features.

Download Data Sheet
TracePartsTraceParts

CAD Models

3D CAD model and technical drawings, ready for your design software.

Download CAD Model

Compatible Products

LAD703F Schneider Electric
LAD703F
Schneider Electric
TeSys LRD remote control device for thermal overload relays LRD/LR3D D01-D35, D04L-D32L, D313-D380, D313L-D365L and LR9D01-D32
LAD703M Schneider Electric
LAD703M
Schneider Electric
TeSys LRD remote control device for thermal overload relays LRD/LR3D D01-D35, D04L-D32L, D313-D380, D313L-D365L and LR9D01-D32
LAD7305 Schneider Electric
LAD7305
Schneider Electric
"TeSys Deca control accessory, Mechanical remote control" "Reset by flexible cable" "Mounting with cable straight or bend,connect with LRD" "compliant (RoHS/REACh)
LAD7B205 Schneider Electric
LAD7B205
Schneider Electric
"TeSys LRD terminal block for mounting of thermal overload relays LRD04L-D32L LR3D04L-D32L LR9D01-D32
LAD7C2 Schneider Electric
LAD7C2
Schneider Electric
This product is a pre-wiring kit of TeSys Deca
XB5AA86102 Schneider Electric
XB5AA86102
Schneider Electric
This manual overload reset pushbutton is part of the range diameter 22mm plastic, Harmony XB5
XB5AL84101 Schneider Electric
XB5AL84101
Schneider Electric
This Harmony XB5, projecting manual overload reset pushbutton is red

Related products

LRD3365 Schneider Electric
LRD3365
Schneider Electric
TeSys LRD thermal overload relay, 104A/1000V, thermal setting range 80-104A, tripping class 10A, for protection of 3-phase motors 45kW@400V
LRD318 Schneider Electric
LRD318
Schneider Electric
Schneider Electric's TeSys LRD thermal overload relay, designed for use with TeSys D contactors. Protects motors up to 7.5kW at 400V.
LRD365L Schneider Electric
LRD365L
Schneider Electric
Schneider Electric's TeSys Deca thermal overload relay offers protection for motors up to 30kW at 400V with a thermal range of 48-65A and tripping class 20.
LRD350 Schneider Electric
LRD350
Schneider Electric
Schneider Electric's TeSys LRD overload relay is designed for use with TeSys D contactors to create a motor starter. This thermal overload relay can handle currents from 40A to 65A and offers an adjustable trip current rating of 37-50A, calibrated to

Market insights

AutomaINSIGHTS analytics dashboard

Get real-time analytics and market data to optimize your purchasing decisions for this component and similar products

  • Real-time stock availability data from 700 MRO distributors in Europe and USA
  • Price analysis by condition (new, used, refurbished) with market median prices
  • Critical component availability monitoring to prevent production downtime
  • Inventory optimization insights based on market supply trends
Get Started

Other Categories