TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 40 amp through 65 amp TeSys D contactors. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 37 to 50 amperes. This trip current rating is calibrated per Class 10A. This overload relay uses EVERLINK termnals in place of the standard terminals.- Country of Origin
- FR
- Part Number
- LRD350
- Tariff Code
- 85364900
- EAN
- 3389119215503
- UNSPSC
- 39122330
€45.00
net€50.00
Shipping from:
€25.00
1
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 2 pcs.In-StockUpdated at: 21-11-2024
- Warranty:
- 24 months
- Estimated Delivery:
- 25-26 November to United Kingdom
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Environment
- Product Certifications
- IEC || UL || CSA || CCC || EAC || DNV-GL || RMRS || EU-RO MR || LROS (Lloyds register of shipping) || ATEX INERIS || UKCA
- Mechanical Robustness
- shocks15 Gn for 11 ms IEC 60068-2-7 || vibrations4 gn IEC 60068-2-6
- Standards
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || EN 50495
- Climatic Withstand
- IACS E10
- Ambient Air Temperature For Operation
- -20-60 °C without derating IEC 60947-4-1
- Dielectric Strength
- 1.89 kV 50 Hz IEC 60947-1
- Ip Degree Of Protection
- IP20 conforming to IEC 60529
- Flame Retardance
- V1 conforming to UL 94
- Ambient Air Temperature For Storage
- -60-70 °C
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP080405EN
- Sustainable Offer Status
- Green Premium product
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- China Rohs Regulation
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Circularity Profile
- ENVEOLI0804005_V1
- Eu Rohs Directive
- Compliant
Complementary
- Network Frequency
- 0...400 Hz
- Height
- 70 mm
- [Ith] Conventional Free Air Thermal Current
- 5 A signalling circuit
- Auxiliary Contact Composition
- 1 NO + 1 NC
- Connections - Terminals
- control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit EverLink BTR screw connectors 1 1-35 mm² flexible without cable end || power circuit EverLink BTR screw connectors 1 1-35 mm² flexible with cable end || power circuit EverLink BTR screw connectors 1 1-35 mm² solid without cable end
- Phase Failure Sensitivity
- tripping current 130 % of Ir on two phase, the last one at 0
- [Ue] Rated Operational Voltage
- 690 V AC 0...400 Hz power circuit IEC 60947-4-1
- Associated Fuse Rating
- 4 A gG for signalling circuit || 4 A BS for signalling circuit
- Net Weight
- 0.375 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV
- Permissible Current
- 0.95 A 380 V AC-15 signalling circuit || 0.06 A 440 V DC-13 signalling circuit
- Tripping Threshold
- 1.14 +/- 0.06 Ir IEC 60947-4-1
- Tightening Torque
- control circuit 1.7 N.m screw clamp terminals || power circuit 5 N.m EverLink BTR screw connectors
- Control Type
- Red push-button stop || Blue push-button reset
- Mounting Support
- plate, with specific accessories || rail, with specific accessories || under contactor
- Width
- 55 mm
- Depth
- 123 mm
- Temperature Compensation
- -20-60 °C
Specifications
- Network Type
- DC || AC
- Thermal Protection Adjustment Range
- 37-50 A
- Relay Application
- motor protection
- Product Or Component Type
- differential thermal overload relay
- Product Name
- TeSys LRD || TeSys Deca
- Thermal Overload Class
- class 10A IEC 60947-4-1
- Range
- TeSys || TeSys Deca
- [Ui] Rated Insulation Voltage
- power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Product Compatibility
- LC1D65A || LC1D50A || LC1D40A
- Device Short Name
- LRD
CAD Models
traceparts
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther