Schneider Electric
LU2MB0FU
1 / 2
Description
Active Mature
TeSys U reversing module for vertical mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 110-240V AC / 110-220V DC. To be used with an advanced power base LUB120, LUB320, or LUB380 equipped with a Control Unit LUC*FU type. To be associated with an assembling connector LU9MR1C and a control terminal block LU9M1 to complete the vertical mounting. Green Premium compliant (RoHS/REACh).- Country of Origin
- FR
- Part Number
- LU2MB0FU
- Tariff Code
- 85369095
- EAN
- 3389110363807
- UNSPSC
- 39121521
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 2 pcs.In-StockUpdated at: 21-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Environment
- Ambient Air Temperature For Operation
- -25-60 °C with LUCM || -25-70 °C with LUCA, LUCB, LUCC, LUCD
- Resistance To Radiated Fields
- 10 V/m level 3 IEC 61000-4-3
- Non-Dissipating Shock Wave
- 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
- Shock Resistance
- 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
- Vibration Resistance
- 2 gn 5-300 Hz) power poles open IEC 60068-2-27 || 4 gn 5-300 Hz) power poles closed IEC 60068-2-27
- Ambient Air Temperature For Storage
- -40-85 °C
- Protective Treatment
- TH IEC 60068
- Ip Degree Of Protection
- IP20 IEC 60947-1 front panel and wired terminals) || IP20 IEC 60947-1 other faces) || IP40 IEC 60947-1 front panel outside connection zone)
- Resistance To Electrostatic Discharge
- 8 kV level 3, in open air IEC 61000-4-2 || 8 kV level 4, on contact IEC 61000-4-2
- Operating Altitude
- 6561.68 ft (2000 m)
- Fire Resistance
- 960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
- Immunity To Radioelectric Fields
- 10 V IEC 61000-4-6
- Resistance To Fast Transients
- 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive
- Compliant with Exemptions
Complementary
- Product Certifications
- CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
- [Ue] Rated Operational Voltage
- 690 V AC power circuit
- Height
- 80 mm
- Connections - Terminals
- control circuit screw clamp terminals 1 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) rigid || power circuit screw clamp terminals 1 1-10 mm² 4 mm) rigid || power circuit screw clamp terminals 1 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² 4 mm) flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) rigid || power circuit screw clamp terminals 2 1.5-6 mm² 4 mm) flexible without cable end
- Net Weight
- 0.4 kg
- Fixing Mode
- plug-in
- [Uimp] Rated Impulse Withstand Voltage
- 6 kVIEC 60947-6-2
- Inrush Restraint Duration
- 25 ms AC || 15 ms DC
- Standards
- EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
- [Ui] Rated Insulation Voltage
- 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
- Compatibility Code
- LU2MB
- Operating Time
- 150 ms with change of direction || 75 ms without change of direction
- Width
- 45 mm
- Tightening Torque
- control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips No 2 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm
- Depth
- 105 mm
- Network Frequency
- 40...60 Hz
Specifications
- Device Mounting
- direct mounting
- [Uc] Control Circuit Voltage
- 110...240 V AC 50/60 Hz || 110...220 V DC
- Product Or Component Type
- reverser block
- Current Consumption
- 1000 mA 110...220 V DC I maximum while closing || 1000 mA 110...240 V AC I maximum while closing
- Range
- TeSys
- [Ie] Rated Operational Current
- 38 A
- Device Application
- motor control
- Device Short Name
- LU2MB