1 / 1
thumbnail

Description

Active Mature
TeSys U reversing module for side mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 24 AC. To be used with an advanced power base LUB120 or LUB320 equipped with a Control Unit LUC*B type. To be associated with an assembling connector LU9MR1 and a control terminal block LU9M1 to complete the side mounting. Green Premium compliant (RoHS/REACh).
Country of Origin
FR
Part Number
LU6MB0B
Tariff Code
85364190
EAN
3389110107050
UNSPSC
39121521
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Environment

Ambient Air Temperature For Operation
-25-60 °C with LUCM || -25-70 °C with LUCA, LUCB, LUCC, LUCD
Resistance To Radiated Fields
10 V/m level 3 IEC 61000-4-3
Non-Dissipating Shock Wave
1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
Shock Resistance
10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Vibration Resistance
2 gn 5-300 Hz) power poles open IEC 60068-2-27 || 4 gn 5-300 Hz) power poles closed IEC 60068-2-27
Ambient Air Temperature For Storage
-40-85 °C
Protective Treatment
TH IEC 60068
Ip Degree Of Protection
IP20 IEC 60947-1 front panel and wired terminals) || IP20 IEC 60947-1 other faces) || IP40 IEC 60947-1 front panel outside connection zone)
Resistance To Electrostatic Discharge
8 kV level 3, in open air IEC 61000-4-2 || 8 kV level 4, on contact IEC 61000-4-2
Operating Altitude
6561.68 ft (2000 m)
Fire Resistance
960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
Immunity To Radioelectric Fields
10 V IEC 61000-4-6
Resistance To Fast Transients
2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive
Compliant with Exemptions

Complementary

Product Certifications
CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
[Ue] Rated Operational Voltage
690 V AC power circuit
Height
115 mm
Connections - Terminals
control circuit screw clamp terminals 1 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) rigid || power circuit screw clamp terminals 1 1-10 mm² 4 mm) rigid || power circuit screw clamp terminals 1 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² 4 mm) flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) rigid || power circuit screw clamp terminals 2 1.5-6 mm² 4 mm) flexible without cable end
Net Weight
0.425 kg
Fixing Mode
clipped DIN rail) || screw-fixed plate)
[Uimp] Rated Impulse Withstand Voltage
6 kVIEC 60947-6-2
Inrush Restraint Duration
25 ms AC || 15 ms DC
Standards
EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
[Ui] Rated Insulation Voltage
690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Compatibility Code
LU6MB
Operating Time
150 ms with change of direction || 75 ms without change of direction
Width
45 mm
Tightening Torque
control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips No 2 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm || power circuit 1.9-2.5 N.m pozidriv No 2 6 mm
Depth
113 mm
Network Frequency
40...60 Hz

Specifications

Device Mounting
separate mounting
[Uc] Control Circuit Voltage
24 V AC 50/60 Hz
Product Or Component Type
reverser block
Current Consumption
2360 mA 24 V AC I maximum while closing
Range
TeSys
[Ie] Rated Operational Current
32 A
Device Application
motor control
Device Short Name
LU6MB

CAD Models

traceparts
traceparts
Download