Schneider Electric
METSEEM3555A
1 / 1
Description
Active Mature
The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xxA models are designed for use exclusively with Rogowski coil CTs where integrator and power supply for the CTs are built into the meter. Not recommanded for high harmonic application. Current input from 20A to 5000A with the Rogowski coil, ANSI C12.20 0.5% accuracy, IEC 62053-22 class 0.5S. The data logging capability protects data in the event of a power failure. Modbus, pulse output, and phase alarms are all provided to suit a wide variety of applications. This model add a bi-directional monitoring feature designed expressly for renewable energy applications. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm and product weight 280 g.- Country of Origin
- US
- Part Number
- METSEEM3555A
- Tariff Code
- 9028300000
- EAN
- 32151802
- UPC
- 785901657088
- UNSPSC
- 32151802
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Complementary
- Network Frequency
- 60 Hz || 50 Hz
- Communication Port Support
- screw terminal block RS485
- [Ue] Rated Operational Voltage
- 90...347 V AC 50/60 Hz between phase and neutral UL || 156...600 V AC 50/60 Hz between phases UL || 90...300 V AC 50/60 Hz between phase and neutral CE || 125...300 V DC
- Standards
- CSA C22.2 No 14-05 || IEC 61010-1 || UL 508
- Number Of Outputs
- 1 alarm output || 1 pulse
- Mounting Support
- DIN rail
- Power Consumption In Va
- 5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)
- Product Certifications
- CE IEC 61010 || cULus UL 508
- Type Of Measurement
- active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency
- Communication Port Protocol
- Modbus RTU 1200…38400 bps - 2-wire
- Communication Service
- total cumulated active energy || total cumulated energy
- Ride-Through Time
- 100 ms 120 V AC
- Display Digits
- 5
- Communication Of Data
- lifetime energy production || instantaneous and demand values
- Tamperproof Of Settings
- protected by access code
- Measurement Current
- 20-5000 A
- Information Displayed
- status and alert || communication with system || input/output status || error || Tx activity || Rx activity || instant power per usage
- Function Available
- fixed or rolling block || external synchronisation to communication
- Mounting Mode
- by screws || clip-on
- Local Signalling
- Red LED threshold reached || Green flashing LED output signal
- Power Consumption In W
- 3 W 300-300 V
- Measurement Accuracy
- power +/- 0.5 % || energy +/- 0.5 %
- Technology Type
- electronic
- Buffer Size
- 16-bit 10
- Poles Description
- 3P + N
- Data Recording
- energy consumption logs || time stamping
- Analogue Input Type
- Rogowski coil 50...5000 A
- Display Type
- Backlit LCD
- Device Application
- sub billing || partial meter
- Accuracy Class
- class 0.5S power IEC 62053-22 || class 0.5S energy IEC 62053-22 || class 0.5S power ANSI C12.20 || class 0.5S energy ANSI C12.20
- Rated Voltage
- 90-347 V
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive
- Compliant with Exemptions
Environment
- Ambient Air Temperature For Operation
- -30-70 °C
- Height
- 91 mm
- 9 Mm Pitches
- 12
- Color
- dark grey
- Ambient Air Temperature For Storage
- -40-85 °C
- Relative Humidity
- 0-95 %
- Width
- 107 mm
- Depth
- 59 mm
Specifications
- Product Or Component Type
- energy meter
- Product Name
- PowerLogic EM3500
- Range
- PowerLogic
- Device Short Name
- EM3555A
- Metering Type
- demand power P, Q, S || peak demand power PM, QM, SM || voltage U21, U32, U13, V1, V2, V3 || active, reactive, apparent energy (signed, four quadrant) || current I1, I2, I3, Iavg
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther