- Product Certifications
- CSA || UL
- Ik Degree Of Protection
- IK08 IEC 62262
- Control Station Application
- control of 2-speed hoist motor
- Terminal Identifier
- (13-14)NO || (11-12)NC
- Ambient Air Temperature For Operation
- -25-70 °C
- Terminals Description Iso N°1
- (23-24)NO_CL || (13-14)NO
- Standards
- IEC 60204-32 || UL 508 || IEC 60947-5-1 || CSA C22.2 No 14
- Maximum Resistance Across Terminals
- 25 MOhm
- Short-Circuit Protection
- 10 A fuse protection cartridge gG
- Cable Entry
- rubber sleeve with stepped entry 7-15 mm
- Shock Resistance
- 100 gn IEC 60068-2-27
- Enclosure Type
- complete ready for use
- Vibration Resistance
- 15 gn 10-500 Hz)IEC 60068-2-6
- Net Weight
- 0.32 kg
- Product Compatibility
- ZB2BE101 + ZB2BE201 for each direction
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947-1
- Ip Degree Of Protection
- IP65 conforming to IEC 60529
- Control Station Type
- double insulated
- Control Type
- intuitive
- Connections - Terminals
- screw clamp terminals, 1 x 2.5 mm² with or without cable end || screw clamp terminals, 2 x 1.5 mm² with or without cable end
- [Ui] Rated Insulation Voltage
- 600 V 3)IEC 60947-1
- Ambient Air Temperature For Storage
- -40-70 °C
- Control Station Composition
- 2 booted push-buttons
- Overvoltage Category
- class II IEC 61140
- Contact Operation
- slow-break || staggered
- Mechanical Interlocking
- with mechanical interlocking
- Control Station Colour
- yellow
- Mechanical Durability
- 1000000 cycles
- Operating Force
- 13-15 N
- Control Button Type
- first push-button 2 NO (2 step) raise, slow-fast || second push-button 2 NO (2 step) lower, slow-fast
- [Ithe] Conventional Enclosed Thermal Current
- 10 A
- Electrical Circuit Type
- control circuit
- Enclosure Material
- polypropylene
- Contact Code Designation
- A600 AC-15, Ue = 240 V, Ie = 3 A IEC 60947-5-1 appendix A || A600 AC-15, Ue = 600 V, Ie = 1.2 A IEC 60947-5-1 appendix A || Q600 DC-13, Ue = 250 V, Ie = 0.27 A IEC 60947-5-1 appendix A || Q600 DC-13, Ue = 600 V, Ie = 0.1 A IEC 60947-5-1 appendix A
- Protective Treatment
- TH
- Rated Operational Power In W
- 40 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C || 48 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C || 65 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C