Schneider Electric
XALD222
1 / 5
Description
Active Mature
This Harmony XALD dark grey control station is ideal to control simple hoists. This dark grey control station enables machine builders to easily add control and signalling functionality on their machines, with permanent modifications or damage to their machine body. It is designed for simple and mass production machines, textiles, packaging, handling small lifting systems, control of garage doors, rolling shutters, smoke extraction vents. It is compatible with Harmony XB5 range push buttons, switches and pilot lights. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments. It is also resistant to chemicals and offers double insulation.- Country of Origin
- FR
- Part Number
- XALD222
- Tariff Code
- 85365080
- EAN
- 3389110114164
- UNSPSC
- 39122216
£22.50
net£25.00
Free Shipping!1
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 2 pcs.In-StockUpdated at: 07-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- 12-13 November to United Kingdom
- Condition:
- New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Environment
- Ik Degree Of Protection
- IK03 IEC 62262
- Ambient Air Temperature For Operation
- -40-70 °C
- Standards
- JIS C8201-5-1 || IEC 60947-1 || CSA C22.2 No 14 || IEC 60947-5-4 || IEC 60947-5-1 || UL 508 || IEC 60947-5-5 || JIS C8201-1
- Shock Resistance
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- Vibration Resistance
- 5 gn 12-500 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP66 IEC 60529 || IP67 || IP69 || IP69K
- Ambient Air Temperature For Storage
- -40-70 °C
- Nema Degree Of Protection
- NEMA 13 || NEMA 4X
- Electrical Shock Protection Class
- class II IEC 60536
- Protective Treatment
- TH
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1806010EN
- Sustainable Offer Status
- Green Premium product
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1806010EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- Operating Force
- 3.8 N NO changing electrical state
- Short-Circuit Protection
- 10 A cartridge fuse gG IEC 60947-5-1
- Operating Travel
- 2.6 mm NO changing electrical state) || 4.3 mm total travel)
- Contacts Material
- silver alloy (Ag/Ni)
- Positive Opening
- without
- [Ith] Conventional Free Air Thermal Current
- 10 A IEC 60947-5-1
- Cable Entry
- 2 knock-outs for cable entry 14-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
- Colour Of Marking
- white marking when green, red or black caps || black marking when white caps
- Net Weight
- 0.233 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947-1
- Resistance To High Pressure Washer
- 7000000 Pa 55 °C 0.1 m
- Electrical Durability
- 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
- Connections - Terminals
- screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
- [Ui] Rated Insulation Voltage
- 600 V 3)IEC 60947-1
- [Ie] Rated Operational Current
- 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 3 A 240 V, AC-15, A600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1
- Mechanical Durability
- 10000000 cycles
- Electrical Reliability
- λ < 10exp(-6) 5 V 1 mA IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA IEC 60947-5-4
- Tightening Torque
- 0.8-1.2 N.m IEC 60947-1
- Shape Of Screw Head
- cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
Specifications
- Control Station Application
- two functions
- Product Destination
- for XB5 Ø 22 mm control and signalling units
- Range Of Product
- Harmony XALD
- Colour Of Base Of Enclosure
- light grey RAL 7035)
- Control Station Composition
- 1 flush push-button, black 1 NO, white down arrow || 1 flush push-button, white 1 NO, black up arrow
- Operators Description
- white ''up arrow'' 1 NO - black ''down arrow'' 1 NO
- Product Or Component Type
- complete control station
- Material
- polycarbonate
- Marking Location
- marking on push-button
- Operator Profile
- 2 flush push-buttons
- Colour Of Cover
- dark grey RAL 7016)
- Contact Operation
- slow-break
- Device Short Name
- XALD
CAD Models
traceparts
Download