This XCSD Compact Safety Limit Switch has a steel roller plunger, a Zamak body and head and a 1/2" NPT cable gland entry. It has 1 normally open and 2 normally closed snap action contacts. Its B10D reliability data is 50 000 000. It has IK06 impact resistance and IP66 / IP67 degree of protection, makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Country of Origin
FR
Part Number
XCSD3902N12
Tariff Code
85365080
EAN
3389110240788
UNSPSC
39122213
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Specifications

Contacts Type And Composition
1 NC + 1 NC + 1 NO
Range Of Product
Telemecanique Safety switches XCS
Cable Entry
1 entry tapped 1/2" NPT
Product Or Component Type
safety limit switch
Protection Technology
plastic protective cover, secured by 5-lobe socket head safety screw
Component Name
XCSD
Design
compact
Material
metal
Head Type
plunger head
Contact Operation
snap action
Type Of Operator
steel roller plunger

Contractual warranty

Warranty
18 months

Complementary

Height
100-100 mm
Short-Circuit Protection
6 A cartridge fuse gG (gl)
Clamping Connection Capacity
1 x 0.34...2 x 0.75 mm²
Repeat Accuracy
0.1 mm on tripping points, 1 million operating cycles for head with end plunger
[Ithe] Conventional Enclosed Thermal Current
6 A
Head Material
zamak
Net Weight
0.255 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-1 || 4 kV IEC 60664
Switch Actuation
by 30° cam
[Ui] Rated Insulation Voltage
300 VUL 508 || 400 V 3)EN/IEC 60947-1 || 300 VCSA C22.2 No 14
Positive Opening Minimum Force
36 N
Positive Opening
with NC contact
Mechanical Durability
10000000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
zamak
Electrical Connection
terminal
Enclosure Material
Plastic
Minimum Force For Tripping
12 N
Contact Code Designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A
Width
34 mm
Depth
35 mm
Number Of Poles
3
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || UL
Ik Degree Of Protection
IK06 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN 1088/ISO 14119 || UL 508 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || EN/IEC 60204-1
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I NF C 20-030 || class I EN/IEC 61140
Safety Reliability Data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Protective Treatment
TC
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508