Specifications

Contacts Type And Composition
2 C/O snap action, silver contacts || 2 C/O staggered, silver contacts
Pressure Sensor Type
electromechanical vacuum sensor
Pressure Sensor Size
-1 bar
Pressure Actuator
diaphragm
Electrical Connection
screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
Controlled Fluid
air 0-70 °C) || fresh water 0-70 °C) || hydraulic oil 0-70 °C)
Awg Gauge
AWG 20...AWG 14
Range Of Product
OsiSense XM
Line Rated Current
3 A, B300, AC-15 (Ue = 120 V)EN/IEC 60947-5-1 || 1.5 A, B300, AC-15 (Ue = 240 V)EN/IEC 60947-5-1 || 0.1 A, R300, DC-13 (Ue = 250 V)EN/IEC 60947-5-1
Scale Type
fixed differential
Product Specific Application
dual stage
Pressure Switch Type Of Operation
detection of 2 single thresholds
Cable Entry
cable gland 9-13 mm
Electrical Circuit Type
control circuit
Enclosure Material
zinc alloy
Product Or Component Type
electromechanical pressure sensor
Maximum Permissible Accidental Pressure
9 bar
Materials In Contact With Fluid
zinc alloy || nitrile || 304L stainless steel
Destruction Pressure
18 bar
Local Display
without
Device Short Name
XMLD
Fluid Connection Type
G 1/4 (female) ISO 228

Contractual warranty

Warranty
18 months

Complementary

Repeat Accuracy
2 %
Height
158 mm
Maximum Operating Rate
120 cyc/mn
Terminal Block Type
8 terminals
[Ui] Rated Insulation Voltage
300 V UL 508 || 500 V EN/IEC 60947-1 || 300 V CSA C22.2 No 14
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Spread Between 2 Stages
0.02-0.88 bar
Natural Differential At High Setting
0.1 bar
Setting
external
Mechanical Durability
3000000 cycles
Width
55 mm
Depth
90 mm
Net Weight
1.015 kg
Natural Differential At Low Setting
0.1 bar
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Maximum Resistance Across Terminals
25 mOhm IEC 255-7 category 3 || 25 mOhm NF C 93-050 method A
Maximum Permissible Pressure - Per Cycle
5 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110914EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CSA || UL || EAC
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
CE || CSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508
Protective Treatment
TC standard version
Electrical Shock Protection Class
class I IEC 1140 || class I IEC 536 || class I NF C 20-030
Operating Position
any position
Vibration Resistance
4 gn 30-500 Hz)IEC 60068-2-6
Shock Resistance
50 gn IEC 60068-2-27
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529