Schneider Electric
XMLP300PD230Q
1 / 1
Description
Active Mature
This pressure transmitter is part of the XMLP range, an offer of electronic pressure sensors. The XMLP transmitters are designed for the vacuum measuring and the pressure measuring. They are compatible with a large number of fluids. This product has a pressure range of 0psi to 300psi, with a maximum permissible accidental pressure at 900psi and a destruction pressure at 2200psi. Made of stainless steel, this transmitter is compact and rugged. It has an analogue output (4mA to 20mA), wich delivers a signal proportional to the measured pressure. It is appropriate for controlling air, fresh water, hydraulic oil, gas and refrigeration fluid. This pressure transmitter features a compact metal body, a 1/4-18NPT (male) 316L stainless steel fluid connector and a M12 electrical connector. It is suitable for machine tools, moulding presses, stamping presses and lifting gear. It complies with RCM, CULus, CE, EAC certifications, and with NSF ANSI 61 and EN/IEC 61326-2-3 standards. Dedicated accessories, to be ordered separatly, are available to facilitate the setting of the transmitter. Switches with a display, sealing gaskets, pre-wired connectors, etc. This transmitter is sold in lots of 25. It operates in all positions. The transmitters of the XMLP range integrate a ceramic pressure measuring cell, providing a high level of sensitivity and good resistance to abrasive fluids.- Country of Origin
- CH
- Part Number
- XMLP300PD230Q
- Tariff Code
- 9026204000
- EAN
- 41111927
- UNSPSC
- 41111927
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Specifications
- Pressure Sensor Type
- pressure transmitter
- Analogue Output Function
- 4...20 mA, 2-wire
- Type Of Output Signal
- analogue
- Controlled Fluid
- fresh water 0-135 °C) || air -40-135 °C) || hydraulic oil -40-135 °C) || gas -40-135 °C) || refrigeration fluid -40-135 °C)
- Range Of Product
- Telemecanique Pressure sensors XM
- Electrical Connection
- 1 male connector M12 4 pins
- Pressure Sensor Size
- 300-300 psi
- Quantity Per Set
- set of 25
- Electrical Circuit Type
- control circuit
- Product Or Component Type
- electronic pressure sensors
- Type Of Packing
- group
- [Us] Rated Supply Voltage
- 12...24 V DC SELV 7-33 V)
- Local Display
- without
- Pressure Sensor Name
- XMLP
- Current Consumption
- < 23 mA
- Fluid Connection Type
- 1/4" - 18 NPT (male)
Complementary
- Accuracy
- 0.1 % of the measuring range
- Diameter
- 26 mm
- [Uimp] Rated Impulse Withstand Voltage
- 0.5 kV
- Mechanical Durability
- 10000000 cycles
- Drift Of The Zero Point
- +/- 0.02 % of measuring range/°K
- Operating Position
- any position
- Electromagnetic Compatibility
- electrostatic discharge immunity test EN/IEC 61000-4-2 8 kV air, 4 kV contact || 1.2/50 µs shock waves immunity test EN/IEC 61000-4-5 1 kV 42 Ohm || immunity to magnetic fields EN/IEC 61000-4-8 100 A/m 50 Hz || electrical fast transient/burst immunity test EN/IEC 61000-4-4 4 kV || susceptibility to electromagnetic fields EN/IEC 61000-4-3 10 V/m 80...3000 MHz || radiated RF fields EN/IEC 61000-4-6 10 V 0.01...80 MHz
- Measurement Accuracy
- +/- 0.5 % of the measuring range
- Protection Type
- reverse polarity || load short-circuit
- Drift Of The Sensitivity
- +/- 0.02 % of measuring range/°K
- Maximum Permissible Accidental Pressure
- 900 psi
- Materials In Contact With Fluid
- stainless steel AISI 316L
- Length
- 36 mm
- Destruction Pressure
- 2200 psi
- Net Weight
- 0.088 kg
- Response Time On Output
- <= 2 ms 10...90 % of full scale
- Pressure Setting Range
- 0-300 psi
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1511013EN
- Sustainable Offer Status
- Green Premium product
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environment
- Product Certifications
- RCM || cULus || CE || EAC
- Ambient Air Temperature For Operation
- -30-85 °C
- Ambient Air Temperature For Storage
- -50-100 °C
- Standards
- EN/IEC 61326-2-3 || NSF ANSI 61
- Shock Resistance
- 100 gn 11 ms EN/IEC 60068-2-27
- Vibration Resistance
- 20 gn 15-2000 Hz) EN/IEC 60068-2-6
- Protective Treatment
- TC
- Ip Degree Of Protection
- IP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529 || IP69K conforming to EN/IEC 60529
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther